← Back
Two family brick
131 WEST 197 STREET
💬 Discuss this project
1920Year Built
2Stories
B1Building Class
R6Zoning
2,742 sfGross Floor Area
2Units
1 Open Violation ▸
Two family brick · 2,500 sf lot · 1.1 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Floor 31 filing · 3 docs
Floor 27p · 2 filings · 17 docs
Floor 15p · 3 filings · 19 docs
Cellar4p · 1 filing · 14 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
URENA CONSTRUCTION & DESIGN1707/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/25/2023$975K—Private party → Private party$356/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
RAMIREZ ENGINEERING PLLC110/02/2025
FANG ARCHITECT403/27/2023
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
URENA CONST & DESIGN INCGeneral Contractor603/21/2026
INFINITI ESC PLUMBING CORPlumbing307/08/2026
C.FALCO ELETL CONT CORPElectrical103/22/2026
ATLAS CONSTRUCTION USA COGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
RAMIREZ ENGINEERING PLLC8679110/02/2025
FANG ARCHITECT5513403/27/2023
Building Lifecycle
All (53)Filed (5)Permit Issued (6)Signed Off (3)Violation (13)Inspection (6)Objection (4)Special Inspection (16)
01/20/2026
Signed off — Alteration
A.REPAIR EXISTING RETAINING WALL AT THE REAR OF THE PROPERTY AND SOLVE VIOLATION NO. V 082025CRW20802BH
X01294273-I1
11/13/2025
Permit issued — General Construction
X01294273-I1-GC-CX
10/14/2025
Objection resolved — Addressed
10/14/2025
Objection resolved — Addressed
10/08/2025
Objection raised — Scope
10/08/2025
Objection raised — Zoning
10/02/2025
Filed — Alteration
A.REPAIR EXISTING RETAINING WALL AT THE REAR OF THE PROPERTY AND SOLVE VIOLATION NO. V 082025CRW20802BH
X01294273-I1
08/20/2025
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
04/13/2023
Signed off — Alteration
INTERIOR RENOVATION FOR 2-FAMILY DWELLINGS BUILDING NO CHANGE USE, EGRESS OR OCCUPANCY.
X00608232-I1
04/12/2023
Signed off — Alteration
X00607850-I1
04/12/2023
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
04/05/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/05/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/31/2023
Permit issued — Plumbing
X00607850-I1-PL
03/31/2023
Permit issued — Plumbing
X00607850-I1-PL
03/30/2023
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
03/27/2023
Filed — Alteration
INTERIOR RENOVATION FOR 2-FAMILY DWELLINGS BUILDING NO CHANGE USE, EGRESS OR OCCUPANCY.
X00608232-P2
03/23/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/22/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
DEZHANG FANG
03/22/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
03/22/2023
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
03/22/2023
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
03/22/2023
Special inspection requirement — Insulation placement and R values
DEZHANG FANG
03/22/2023
Special inspection requirement — Fenestration areas
DEZHANG FANG
03/22/2023
Special inspection requirement — Interior lighting power
DEZHANG FANG
03/22/2023
Special inspection requirement — Fenestration air leakage
DEZHANG FANG
07/07/2022
Permit issued — General Construction
X00608232-I1-GC
01/25/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/19/2022
Permit issued — Plumbing
X00607850-I1-PL
01/13/2022
Filed — Alteration
X00607850-I1
10/20/2021
Permit issued — General Construction
X00608232-I1-GC
10/13/2021
Filed — Alteration
INTERIOR RENOVATION FOR 2-FAMILY DWELLINGS BUILDING NO CHANGE USE, EGRESS OR OCCUPANCY.
X00608232-P1
10/13/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
DEZHANG FANG
10/13/2021
Special inspection requirement — Energy Code Compliance Inspections
DEZHANG FANG
10/13/2021
Special inspection requirement — Fire-Resistance Rated Construction
DEZHANG FANG
10/13/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
DEZHANG FANG
10/13/2021
Special inspection requirement — Fenestration air leakage
DEZHANG FANG
10/13/2021
Special inspection requirement — Insulation placement and R values
DEZHANG FANG
10/13/2021
Special inspection requirement — Interior lighting power
DEZHANG FANG
10/13/2021
Special inspection requirement — Fenestration areas
DEZHANG FANG
10/08/2021
Filed — Alteration
INTERIOR RENOVATION FOR 2-FAMILY DWELLINGS BUILDING NO CHANGE USE, EGRESS OR OCCUPANCY.
X00608232-I1
07/12/2019
Violation issued (HPD, closed)
B
07/12/2019
Violation issued (HPD, closed)
A
07/12/2019
Violation issued (HPD, closed)
B
07/12/2019
Violation issued (HPD, closed)
B
06/06/2018
Violation issued (HPD, closed)
C
05/14/2018
Violation issued (HPD, closed)
B
05/14/2018
Violation issued (HPD, closed)
A
05/14/2018
Violation issued (HPD, closed)
B
05/14/2018
Violation issued (HPD, closed)
B
05/14/2018
Violation issued (HPD, closed)
B
05/14/2018
Violation issued (HPD, closed)
B
05/14/2018
Violation issued (HPD, closed)
C
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offATLAS CONSTRUCTION USA CO11/13/2025
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR03/31/2023
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR03/31/2023
DOB NOWGeneral ConstructionSigned-offURENA CONST & DESIGN INC07/07/2022
DOB NOWPlumbingSigned-offINFINITI ESC PLUMBING COR01/19/2022
DOB NOWGeneral ConstructionSigned-offURENA CONST & DESIGN INC10/20/2021
2 projects · most recent 04/20/2023
General Wiring
FiledStatusContractorScope
04/20/2023CompleteC.FALCO ELETL CONT CORPGeneral Wiring
07/15/2021CompleteC.FALCO ELETL CONT CORP2 meters
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
04/12/2023Pass-Final General Construction Non-Directive 14PassView ↗
04/05/2023Fail-Final General Construction Non-Directive 14FailView ↗
04/05/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/30/2023Fail-Final PL - Up to 3 Requested FloorsFailView ↗
03/23/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/25/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
03/22/2023Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
03/22/2023Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
03/22/2023Energy Code Compliance InspectionsDEZHANG FANGprogress
03/22/2023Fire-Resistance Rated ConstructionDEZHANG FANGprogress
03/22/2023Insulation placement and R valuesDEZHANG FANGenergy_progress
03/22/2023Fenestration areasDEZHANG FANGenergy_progress
03/22/2023Interior lighting powerDEZHANG FANGenergy_progress
03/22/2023Fenestration air leakageDEZHANG FANGenergy_progress
10/13/2021Fire-Resistant Penetrations and JointsDEZHANG FANGspecial
10/13/2021Energy Code Compliance InspectionsDEZHANG FANGprogress
10/13/2021Fire-Resistance Rated ConstructionDEZHANG FANGprogress
10/13/2021Fenestration and door U-factor and product ratingsDEZHANG FANGenergy_progress
10/13/2021Fenestration air leakageDEZHANG FANGenergy_progress
10/13/2021Insulation placement and R valuesDEZHANG FANGenergy_progress
10/13/2021Interior lighting powerDEZHANG FANGenergy_progress
10/13/2021Fenestration areasDEZHANG FANGenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/25/2026X00608232-P1Request digital key ↗
08/25/2026X00608232-I1Request digital key ↗
08/25/2026X00608232-P2Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026X00608232-I1Open ↗
08/25/2026X00608232-P2Open ↗
08/25/2026X00608232-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
08/26/2026X00608232-P1Open ↗
08/26/2026X00608232-P1Open ↗
08/23/2026X00608232-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026X00608232-P1Open ↗
08/23/2026X00608232-P2Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form2
08/25/2026X00608232-I1Open ↗
08/24/2026X00607850-I1Open ↗
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026X00608232-I1Open ↗