HPD04/29/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB04/08/2026FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. AT TIME OF INSPECTION AT EXPOSURE 1. BROKEN WINDOW PANE & DAMAGED & DETERIORATED BROWNSTONES WERE OBSERVED. REMEDY: REPAIR AND/OR REPLACE
ECB04/08/2026TEMPORARY CONSTRUCTION EQUIPMENT ON SITE; EXPIRED PERMIT. NOTED AT THETIME OF INSPECTION, I OBSERVED EXPIRED PERMIT FOR CONSTRUCTION FENCE. REMEDY: RENEW PERMIT.$6K due
HPD11/17/2025§27-2107 ADM CODE OWNER FAILED TO FILE A VALID REGISTRATION STATEMENT WITH THE DEPARTMENT AS REQUIRED BY ADM CODE §27-2097 AND IS THEREFORE SUBJECT TO CIVIL PENALTIES, PROHIBITED FROM CERTIFYING VIOLATIONS, AND DENIED THE RIGHT TO RECOVER POSSESSION OF PREMISES FOR NONPAYMENT OF RENT UNTIL A VALID REGISTRATION STATEMENT IS FILED.
ECB10/02/2025AT TIME OF INSPECTION OF VACANT RESIDENTIAL BUILDING WITH CONSTRUCTION FENCE IN PLACE WITH PERMIT M00452904 EXPIRED 6-24-25 CAUSING HAZARDOUS CONDITIONS.$6K due
HPD06/04/2025(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB03/04/2025FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. OBSERVED AT EXP 1 SOUTH ELEVATION HAZARDOUS DETERIORATING FACADE CONDITIONS COLLAPSING SECTION OF WINDOW LINTELS @ MANY LOCATIONS. DAMAGED BROWN STONES MISSING WINDOW SASH/AND PANE ALSO BROKEN WINDOW PANE REMEDY: REPAIR AND/OR REPLACE
DOB09/25/2024FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER.AT TIME OF INS PECTION IT WAS OBSERVED AT EXP1 SOUTH ELEV BROKEN AND SPALLING WINDOW LINTELS,DAMAGED MASONRY FACADE,DETERIORATED WINDOW SILLS AND BOARDED U P WINDOWS.REMEDY:REPAIR AND/OR REPLACE
DOB04/30/2024FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER.NOTE OBSERVED AT EXP1 SOUTH ELEVATION DETERIORATION OF FACADE IN HAZARDOUS CONDITION ON ALL FLOORS LOOSE MASONRY/DAMAGED BROWN STONES.REMEDY:REPAIR &/OR REPL
HPD04/01/2024(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB03/04/2024EMER WRK ORD:4 STRY STRUCT W/SUBSTANTIAL UNSAFE FACADE MATERI EXP4.FAC ADE IN SEVERELY DETERIORATED STATE W/NUMEROUS LOC CRACKED MASONRY BRKN &FALLEN WHICH SOME FELL PAST INSTALL SIDEWALK SHED. REMEDY: IMMED PROV IDE ADDI SAFE MEAS TO ELIMINATE OVERHEAD HAZARD STABILITY.IMMED HIRE NYSPE INSPECT STABILITY SUBMT FORENSICENG@BUILDINGS.NYC.GOV
DOB03/04/2024FAILURE TO MAINTAIN BUILDING IN CODE COMPLIANT MANNER. AT TIME OF INSPECTION BUILDING HAD SEVERAL HAZARDOUS CONDITIONS ON EXPOSURE 1 (SOUTH ELEVATION) SUCH AS SEVERLY DETERIORATED MASONRY, CRACKED SPALLED MASONRY,SOME AREAS BROKEN OFF & FALLEN.REMEDY: REPAIR AND OR REPLACE HAZARDOUS CONDITIONS THAT EXIST
DOB04/25/2023VIOLATION ISSUED-FAILURE TO FILE 2022 EXTERNAL LOW PRESSURE INSPECTION
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB07/19/2018FAILURE TO MAINTAIN LANDMARK BUILDING IN A SAFE CONDITION. THE FRONT FACADE AND REAR WALL ARE IN DISREPAIR WITH ORNAMENTAL STONE LINTELS, NICHES AND SILLS DETACHING FROM MASONRY BACK UP WALLS. THIS REPRESENTS A DANGER TO PUBLIC & ADJ BLDGS. OWNER HAS TO ENGAGE A PE & CONTRACTOR TO EVALUATE BLDG. OBTAIN PERMIT BY 8/31/18, SIGN OFF BY 12/14/18
DOB04/06/2018VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2016 INSPECTION REPORT
DOB02/24/2017VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2015 INSPECTION REPORT
DOB10/01/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2014 INSPECTION REPORT
DOB03/03/2015VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2013 INSPECTION REPORT
DOB02/11/2015FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB11/05/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/10/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB07/02/2014FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
HPD05/28/2006SECTION 27-2040 ADM CODE PROVIDE ADEQUATE LIGHTING AT OR NEAR THE OUTSIDE OF THE FRONT ENTRANCEWAY OF THE BUILDING AND KEEP SAME BURNING FROM SUNSET EVERY DAY TO SUNRISE ON THE DAY FOLLOWING 100 WATTS REQUIRED
DOB01/31/2005V-DOB VIOLATION - ACTIVE
HPD11/24/2001SECTION 27-2033 ADM CODE PROVIDE READY ACCESS TO BUILDINGS HEATING SYSTEM DOOR LOCKED AT CELLAR
HPD11/24/2001SECTION 27-2031 ADM CODE PROVIDE HOT WATER AT ALL HOT WATER FIXTURES IN THE ENTIRE APARTMENT LOCATED AT APT 5B, 4th STORY, 1st APARTMENT FROM WEST AT NORTH
DOB02/07/2000V-DOB VIOLATION - ACTIVE
HPD06/17/1998D26-10.01 ADM CODE REPLACE WITH NEW THE BROKEN OR DEFECTIVE SPRINKLER HEADS PAINTED PUBLIC HALL STAIRS ALL STYS.
HPD06/17/1998SECTION 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM 1 STY PUBLIC HALL & ON BOILER ROOM DOOR.
HPD06/17/1998D26-20.08,20.09 ADM CODE PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS 3RD STY REAR APT 4B. , SECTION '' ''
HPD06/17/1998D26-20.01 ADM CODE PROVIDE A PEEP HOLE IN ENTRANCE DOOR OF THE DWELLING UNIT SO LOCATED SO AS TO PERMIT A PERSON INSIDE THE DWELLING TO VIEW ANY PERSON OUTSIDE ENTRANCE DOOR 3 STY REAR APT.
HPD06/17/1998D26-10.01 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF SKYLIGHTS OF AIRSHAFTS ROOF AT CENTER WEST.
HPD06/12/1998SECTION 27-2005 ADM CODE PROPERLY REPAIR THE BROKEN OR DEFECTIVE LOCK AND DOOR KNOB AT ENTRANCE DOOR TO 4 STY NORTH APT 5B , SECTION '' ''
HPD06/12/1998SECTION 300 M/D LAW FILE PLANS AND APPLICATION AND LEGALIZE THE FOLLOWING ALTERATION OR RESTORE TO THE LEGAL CONDITION EXISTING PRIOR TO THE MAKING OF SAID ALTERATION DOOR AND PARTITION ERECTED BASEMENT STY PUBLIC HALL AT CENTER.
DOB02/10/1997V-DOB VIOLATION - ACTIVE
DOB08/29/1995V-DOB VIOLATION - ACTIVE
DOB09/01/1994V-DOB VIOLATION - ACTIVE
ECB03/21/2024AT TIME OF INSPECTION OBSERVED ABANDONED BUILDING INSTATE OF DISREPAIR CONDITIONS WITH DECORATIVE FACADE STONES AROUND WINDOWS LOOSE, SPALLING AND MISSING SECTION ON FRONT FACADE EXPO # 01. ALSO OBSERVED WINDOWNothing owed — awaiting certificate of correction
ECB07/27/2022PROHIBITED OUTDOOR ADVERTISING COMPANY SIGN ON SIDEWALK SHED OR CONSTRUCTION FENCE.IN REPSPONSE TO COMPLAINT & AT TIME OF INSPECTION OF EXISTING 5 STORY BUILDING OBSERVED AT EXP #1 JOBSITE FENCE WITH ADVERTISINNothing owed — awaiting certificate of correction
ECB11/25/2020FAILURE TO COMPLY WITH THE COMMISSIONERS ORDER TO FILE A CORRECTION WITH THE DEPARTMENT OF BUILDINGS: NOTED: UPON INSPECTION TEMPORARY CONSTRUCTION FENCE UNDER PERMIT 122747983 IS ERECTED IN FRONT OF VACANT BUINothing owed — awaiting certificate of correction
ECB05/10/2018MAINTAIN EXTERIOR BUILDING WALL FAILURE TO MAINTAIN BUILDING WALL OR APPURTENANCES. OBSERVED AT BUILDING FRONT SEVERELY ERODED FACADE AT ALL STORIES. RMDY: MAINTAIN EXTERIOR BUILDING WALL.Nothing owed — awaiting certificate of correction
ECB03/17/2015FAILURE TO COMPLY W/COMMISSIONER'S ORDER TO FILE A CERTIFICATE OF CORRECTION W/DOB FOR NOV#351085813 ISSUED ON 10/18/12 PURSUANT TO 28-204.4AND 1RCNY 102-01. RMDY: FILE A CERTIFICATION OF CORRECTION.Nothing owed — awaiting certificate of correction
ECB01/20/2015FAILURE TO MAINTAIN BLDG NOTED:FOUND,CRACKED & SPALLING OF CONCRETE ALONG FOUND FACADE OF A BROWN STONE BLDG @VARIOUS LOCNS.REPAIR DEFECT FORTHWITH.REM:MAINTAIN BLDG.Nothing owed — awaiting certificate of correction
ECB12/20/2014FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: AT FRONT FACADE (EXP 1) DEFECTIVE FACADE AT VARIOUS LOCATIONS THROUGHOUT,SPALLING BROWNSTONE,CRACKS,BULGING & MISSING SECTION OF BROWNSTONE.Nothing owed — awaiting certificate of correction
ECB10/29/2014FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER. NOTED: AT EXTERIOR STAIRWELL LEADING TO BASEMENT, THE FOLLOWING WAS OBSERVED : (1) APPROX3 FT DEEP, DUMPED GARBAGE CONTAINING SMELLY GARBAGE & A VERY HIGH PERCNothing owed — awaiting certificate of correction
ECB08/11/2014FAILURE TO MAINTAIN BLDG IN CODE COMPLAINT MANNER.NOTED:@ FRONT FACADE(EXP#1)DEFECTIVE DACADE @ VARIOUS LOCATIONS THROUGHOUT:SPALLING BROWNSTONE CRACKS BULGING MISSING SECTION OF BROWNSTONE PIECES OF BROWN STONNothing owed — awaiting certificate of correction
ECB06/11/2014FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:@ FRONT FACADE(EXP#1)DEFECTIVE FACADE @ VARIOUS LOCATIONS THROUGHOUT,SPALLING BROWNSTONE,CRACKS,BULGING,MISSING SECTION OF BROWNSTONE,PIECES OF BROWNSTONENothing owed — awaiting certificate of correction
ECB04/03/2014FAIL TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER.NOTE:@FRONT FACADE @VARIOUS LOCATIONS THRUOUT EXP #1 SPALLING BROWNSTONE,CRACKS,BULDING,MISSING SECTION OF BROWNSTONE,PIECES OF BROWNSTONE INDANGER OF FALLING TO SNothing owed — awaiting certificate of correction
ECB12/02/2013FAILURE TO MAINTAIN BLDG IN CODE COMPLIANT MANNER.NOTED:AT FRONT FACADE EXPOSURE #1 DEFETIVE.DEFECTIVE FACADE AT VARIOUS LOCATIONS THROUGH OUT FACADE.DEFETS NOTED SPALLING BROWNSTONE,CRACKS, BULGING MISSINGNothing owed — awaiting certificate of correction
City residence, one family · Owner of record: DMC GC PROPERTY, L.P. · 2,008 sf lot · 3.46 FAR built · Flood zone X