← Back
Walk-up apt, over six families with stores
1310 FLATBUSH AVENUE
BROOKLYN · BIN 3327323
💬 Discuss this project
1931Year Built
3Stories
C7Building Class
R7AZoning
7,800 sfGross Floor Area
10Units
Rent Stabilized99 Open Violations 90 unresolved · 9 paperwork only ▸FDNY Report ↗
Walk-up apt, over six families with stores · Owner of record: FLATBUSH PROPERTY 1310 OPERATOR LLC · 2,420 sf lot · 3.22 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Permit Issued — active, not yet Signed-off
RoofUnder Construction9p · 1 filing · 20 docs
BulkheadUnder Construction1p · 1 filing · 20 docs
Floor 3Under Construction26p · 1 filing · 20 docs
Floor 2Under Construction26p · 1 filing · 20 docs
Floor 1
1 job · most recent 05/04/2026
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
05/04/2026Permit IssuedRODEAL INCAir Conditioning Systems, Heating Systems
Cooling
Mitsubishi Electric MUZ-GL 15NA-U1 2,200 BTU · Condensing Unit ×4
Heating
Mitsubishi Electric MSZ-GL15NA-U1 3,000 BTU · Fan Coil Indoor ×9
1 job · most recent 05/04/2026
Gas Water/Sanitary
FiledStatusContractorScope
05/04/2026Permit IssuedRITE WAY HEATING CORPGas, Water/Sanitary
1 job · most recent 06/18/2026
General Wiring
FiledStatusContractorScope
06/18/2026Permit IssuedA.L. ELECTRICAL CORP.General Wiring
Building Lifecycle
All (123)Filed (5)Permit Issued (4)Violation (60)Inspection (2)Objection (22)Special Inspection (30)
07/13/2026
Permit issued — General Construction
B01229606-I1-GC
06/16/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/11/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
05/11/2026
Special inspection requirement — Permanent certificate
William Alicea
05/11/2026
Special inspection requirement — HVAC-R and service water heating system controls
William Alicea
05/11/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
William Alicea
05/11/2026
Special inspection requirement — Maintenance information
William Alicea
05/11/2026
Special inspection requirement — HVAC-R and service water heating equipment
William Alicea
05/11/2026
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
05/04/2026
Filed — Alteration
HEREWITH TO PROPOSE NEW MECHANICAL SYSTEMS HEATING & COOLING SYSTEM, INCONJUNCTION WITH DOB JOB # B01229606-I1
B01229606-P2
05/04/2026
Violation issued (HPD, open)
A
04/17/2026
Objection resolved — Resolved
04/06/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/31/2026
Objection raised — Scope
03/26/2026
Special inspection requirement — Permanent certificate
William Alicea
03/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
03/26/2026
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
03/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
William Alicea
03/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
William Alicea
03/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
William Alicea
03/26/2026
Special inspection requirement — Maintenance information
William Alicea
03/23/2026
Permit issued — Plumbing
B01229606-S1-PL
03/20/2026
Permit issued — Mechanical Systems
B01229606-S2-MS
03/19/2026
Filed — Alteration
HEREWITH TO PROPOSE NEW MECHANICAL SYSTEMS HEATING & COOLING SYSTEM, INCONJUNCTION WITH DOB JOB # B01229606-I1
B01229606-P1
02/27/2026
Special inspection requirement — Fire-Resistance Rated Construction
William Alicea
02/27/2026
Special inspection requirement — Final
William Alicea
02/27/2026
Special inspection requirement — Energy Code Compliance Inspections
William Alicea
02/27/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
William Alicea
02/27/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
William Alicea
02/27/2026
Special inspection requirement — Fenestration air leakage
William Alicea
02/27/2026
Special inspection requirement — Fenestration areas
William Alicea
02/27/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
William Alicea
02/27/2026
Special inspection requirement — Lighting in dwelling units
William Alicea
02/27/2026
Special inspection requirement — Interior lighting power
William Alicea
02/27/2026
Special inspection requirement — Air barrier - visual inspection
William Alicea
11/18/2025
Violation issued (HPD, open)
I
11/10/2025
Permit issued — General Construction
B01229606-I1-GC
10/28/2025
Filed — Alteration
HEREWITH TO PROPOSE NEW MECHANICAL SYSTEMS HEATING & COOLING SYSTEM, INCONJUNCTION WITH DOB JOB # B01229606-I1
B01229606-S2
10/08/2025
Special inspection requirement — HVAC-R and service water heating equipment
William Alicea
10/08/2025
Special inspection requirement — Maintenance information
William Alicea
10/08/2025
Special inspection requirement — Permanent certificate
William Alicea
10/08/2025
Special inspection requirement — Heating Systems
William Alicea
10/08/2025
Special inspection requirement — HVAC-R and service water heating system controls
William Alicea
09/11/2025
Objection resolved — Addressed
08/29/2025
Objection resolved — Addressed
07/18/2025
Objection raised — Scope
07/18/2025
Objection raised — Scope
07/17/2025
Filed — Alteration
HEREWITH TO PROPOSE NEW MECHANICAL SYSTEMS HEATING & COOLING SYSTEM, INCONJUNCTION WITH DOB JOB # B01229606-I1
B01229606-S1
07/15/2025
Objection resolved — Addressed
07/07/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
07/03/2025
Objection resolved — Addressed
06/23/2025
Objection raised — Plumbing
06/23/2025
Objection raised — Scope
06/23/2025
Objection raised — Scope
06/23/2025
Objection raised — Cost
Latest 60 of 123 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
RODEAL709/13/2026
1310-1312 FLATBUSH AVENUE603/22/2026
OWNER OF 2649 BEDFORD AVE203/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/08/2025$2.2M—— → —$282/sf building
06/20/2018$3.5M—— → —$442/sf building
02/03/2015$2.3M—BEDFORD AVENUE HOLDING LLC → 1310-1312 FLATBUSH AVE LLC$295/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
WORLD DESIGN ARCHITECTURE,PLLC505/04/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
NYC BUILDING SOLUTIONS303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
RODEAL INCGeneral Contractor307/14/2026
RITE WAY HEATING CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
WORLD DESIGN ARCHITECTURE9323505/04/2026
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedRODEAL INC07/13/2026
DOB NOWPlumbingPermit IssuedLS PLUMBING CORP03/23/2026
DOB NOWMechanical SystemsPermit IssuedRODEAL INC03/20/2026
DOB NOWGeneral ConstructionPermit IssuedRODEAL INC11/10/2025
BISBLISSUEDBAYSIDE FUEL OIL CORP.12/24/1991
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
06/16/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/06/2026Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 45
DateRequirementInspectorRole
05/11/2026Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
05/11/2026Permanent certificateWilliam Aliceaenergy_progress
05/11/2026HVAC-R and service water heating system controlsWilliam Aliceaenergy_progress
05/11/2026HVAC-R and service water piping design and insulationWilliam Aliceaenergy_progress
05/11/2026Maintenance informationWilliam Aliceaenergy_progress
05/11/2026HVAC-R and service water heating equipmentWilliam Aliceaenergy_progress
05/11/2026Energy Code Compliance InspectionsWilliam Aliceaprogress
03/26/2026Permanent certificateWilliam Aliceaenergy_progress
03/26/2026Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
03/26/2026Energy Code Compliance InspectionsWilliam Aliceaprogress
03/26/2026HVAC-R and service water piping design and insulationWilliam Aliceaenergy_progress
03/26/2026HVAC-R and service water heating equipmentWilliam Aliceaenergy_progress
03/26/2026HVAC-R and service water heating system controlsWilliam Aliceaenergy_progress
03/26/2026Maintenance informationWilliam Aliceaenergy_progress
02/27/2026Fire-Resistance Rated ConstructionWilliam Aliceaprogress
02/27/2026FinalWilliam Aliceaprogress
02/27/2026Energy Code Compliance InspectionsWilliam Aliceaprogress
02/27/2026Fire-Resistant Penetrations and JointsWilliam Aliceaspecial
02/27/2026Fenestration and door U-factor and product ratingsWilliam Aliceaenergy_progress
02/27/2026Fenestration air leakageWilliam Aliceaenergy_progress
02/27/2026Fenestration areasWilliam Aliceaenergy_progress
02/27/2026Structural Stability – Alterations of existing buildingsWilliam Aliceaspecial
02/27/2026Lighting in dwelling unitsWilliam Aliceaenergy_progress
02/27/2026Interior lighting powerWilliam Aliceaenergy_progress
02/27/2026Air barrier - visual inspectionWilliam Aliceaenergy_progress
Latest 25 of 45.
▾Documents — 28 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026B01229606-I1Request digital key ↗
08/17/2026B01229606-S1Request digital key ↗
08/17/2026B01229606-S2Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications20
▸DOB NOWProgress Inspector Seal & Signature10
09/23/2026B01229606-S2Open ↗
09/23/2026B01229606-S2Open ↗
08/31/2026B01229606-P2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/17/2026B01229606-I1Open ↗
08/17/2026B01229606-P2Open ↗
08/13/2026B01229606-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature5
09/23/2026B01229606-S2Open ↗
08/31/2026B01229606-P2Open ↗
08/28/2026B01229606-I1Open ↗
Showing 3 of 5 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/17/2026B01229606-I1Open ↗
08/13/2026B01229606-P1Open ↗
08/13/2026B01229606-S2Open ↗
▸DOB NOWDEP ACP-20/ACP-21: Asbestos Project Conditional Completion Form/Asbestos Project Completion Form1
08/13/2026B01229606-S1Open ↗