← Back
Over six families without stores
1314 RIVERSIDE DRIVE
MANHATTAN · BIN 1064325
💬 Discuss this project
1926Year Built
6Stories
C1Building Class
R7-2Zoning
41,310 sfGross Floor Area
64Units
LL97 CoveredRent Stabilized25 Open Violations 24 unresolved · 1 paperwork only ▸
Over six families without stores · Owner of record: HP CSP GF1 HOUSING DEVELOPMENT FUND COMP ANY, INC. · 14,375 sf lot · 2.87 FAR built · Flood zone X
Locations of Work
Plumbing
Permit Issued — active, not yet Signed-off
CellarUnder Construction25p · 1 filing · 12 docs
Sub-Basement1 filing · 4 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW AMERICAN CONSTRUCTION INC707/08/2026
J G CONSTRUCTION SRVCS407/08/2026
JASCO707/08/2026
HP CSP GF1 HOUSING DEVELOPMENT FUND COMP ANY, INC.103/22/2026
BELLA VISTA REALTY CO403/22/2026
1312-1322 RIVERSIDE DRIVE LLC803/22/2026
BELLA VISTA RELATY CO INC103/22/2026
SHELL CONSTRUCTION103/22/2026
BELLA VISTA REALTY COR203/22/2026
CLASSIE REALTY & MGMT103/22/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/11/2020$10.2M—— → —$246/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARCHITECTURAL SOLUTIONS501/09/2025
SYED ENGINEERING, P.C.309/09/2020
GREEN DESIGN210/09/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ATLANTIC BUILDING SUPPLY INC.403/21/2026
ADVANCED BUILDERS SERVICES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
GJ PLUMBING LLCPlumbing807/08/2026
C & J CONST AND PAINTINGGeneral Contractor307/08/2026
NATIONWIDE MECHANICAL INCPlumbing203/22/2026
JASCO, INCGeneral Contractor207/08/2026
NEW AMERICAN CONSTRUCTION INCGeneral Contractor207/08/2026
J & G CONSTRUCTION SVCSGeneral Contractor107/08/2026
FRANK FODERAElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ARCHITECTURAL SOLUTIONS3959501/09/2025
Building Lifecycle
All (107)Filed (10)Permit Issued (15)Signed Off (4)Violation (60)Inspection (13)Special Inspection (5)
07/01/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/30/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
05/20/2026
Violation issued (HPD, open)
B
02/27/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
01/23/2026
Inspection — No Access-Final PL - Up to 3 Requested Floors
No Access
View inspection ↗
01/21/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
01/16/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/26/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/17/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
09/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/17/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/15/2025
Violation issued (HPD, closed)
A
09/15/2025
Violation issued (HPD, closed)
C
09/02/2025
Permit issued — Plumbing
M08035175-I1-PL
08/26/2025
Violation issued (HPD, closed)
B
08/26/2025
Violation issued (HPD, closed)
B
08/20/2025
Violation issued (HPD, closed)
B
08/20/2025
Violation issued (HPD, closed)
B
08/20/2025
Violation issued (HPD, closed)
B
08/20/2025
Violation issued (HPD, closed)
C
08/06/2025
Violation issued (HPD, closed)
A
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, open)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, closed)
B
08/06/2025
Violation issued (HPD, open)
B
08/06/2025
Violation issued (HPD, closed)
C
08/06/2025
Violation issued (HPD, closed)
A
04/11/2025
Violation issued (HPD, closed)
B
04/11/2025
Violation issued (HPD, closed)
C
04/11/2025
Violation issued (HPD, closed)
C
04/11/2025
Violation issued (HPD, closed)
C
04/11/2025
Violation issued (HPD, closed)
C
04/11/2025
Violation issued (HPD, closed)
B
04/11/2025
Violation issued (HPD, closed)
C
04/11/2025
Violation issued (HPD, closed)
C
03/27/2025
Violation issued (ECB, closed)
Construction
03/26/2025
Violation issued (HPD, closed)
C
02/14/2025
Violation issued (HPD, closed)
C
02/14/2025
Violation issued (HPD, closed)
C
02/01/2025
Violation issued (HPD, closed)
C
02/01/2025
Violation issued (HPD, closed)
B
01/30/2025
Violation issued (HPD, closed)
B
01/30/2025
Violation issued (HPD, closed)
C
01/30/2025
Violation issued (HPD, closed)
B
01/13/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
Jorge Lee
01/13/2025
Special inspection requirement — Tenant Protection Plan Compliance
Jorge Lee
01/13/2025
Special inspection requirement — Energy Code Compliance Inspections
Jorge Lee
01/09/2025
Filed — Alteration
REINSTALLATION OF ALL GAS METERS FROM APARTMENTS TO FIRST FLOOR METER ROOM RE-PIPING ALL RISERS THRU EXISTING INTERIOR WALLS TO THE COOKING STOVE SECTION OF THE KITECHN IN ALL THE APARTMENTS.
M08035175-P2
01/03/2025
Violation issued (HPD, closed)
B
01/03/2025
Violation issued (HPD, closed)
B
01/03/2025
Violation issued (HPD, closed)
C
01/03/2025
Violation issued (HPD, closed)
A
01/03/2025
Violation issued (HPD, closed)
C
01/03/2025
Violation issued (HPD, closed)
A
Latest 60 of 107 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP09/02/2025
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP06/27/2024
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP06/25/2024
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP07/06/2023
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP06/30/2023
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP11/29/2022
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP07/12/2022
DOB NOWPlumbingPermit IssuedTVS MECHANICAL CORP11/10/2021
DOB NOWGeneral ConstructionPermit IssuedC & J CONST AND PAINTING06/15/2021
DOB NOWGeneral ConstructionPermit IssuedC & J CONST AND PAINTING04/19/2021
DOB NOWSidewalk ShedPermit IssuedJ & G CONSTRUCTION SVCS09/09/2020
DOB NOWSupported ScaffoldSigned-offJASCO, INC10/15/2019
DOB NOWSidewalk ShedSigned-offJASCO, INC10/15/2019
DOB NOWSupported ScaffoldSigned-offNEW AMERICAN CONSTRUCTION10/15/2019
DOB NOWSidewalk ShedSigned-offNEW AMERICAN CONSTRUCTION10/10/2019
BISOTISSUEDDK BUILDERS INC10/06/2020
BISOTISSUEDDK BUILDERS INC06/30/2020
BISOTISSUEDRK CONTRACTING INC06/16/2020
BISFBISSUEDAMBASSADOR FUEL & OIL CORPORATIO08/19/2002
BISFBISSUEDSTUYVESANT OIL BURNER CORP.12/08/1997
1 project · most recent 01/09/2025
Gas
FiledStatusContractorScope
01/09/2025Permit IssuedTVS MECHANICAL CORPGas
3 projects · most recent 10/06/2021
General Wiring
FiledStatusContractorScope
10/06/2021Permit IssuedAL ELECTRICAL GROUP INCGeneral Wiring
08/14/2020Permit IssuedRICHARD NEU—
10/14/2019CompleteRICHARD NEU—
1 project · most recent 09/09/2020
Sidewalk Shed
FiledStatusContractorScope
09/09/2020Permit IssuedJ & G CONSTRUCTION SVCSSidewalk Shed
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
07/01/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/30/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/27/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
01/23/2026No Access-Final PL - Up to 3 Requested FloorsNo AccessView ↗
01/21/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
01/16/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
12/26/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/17/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
09/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/17/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/01/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
12/03/2021Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
11/18/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
01/13/2025Fire-Resistant Penetrations and JointsJorge Leespecial
01/13/2025Tenant Protection Plan ComplianceJorge Leespecial
01/13/2025Energy Code Compliance InspectionsJorge Leeprogress
10/08/2019FinalBRIAN T. O'CONNORprogress
10/08/2019FinalBRIAN T. O'CONNORprogress
▾Documents — 96 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch4
09/03/2026M00614475-I1Request digital key ↗
08/25/2026M08035175-P1Request digital key ↗
08/25/2026M08035175-P2Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Sidewalk Shed3
09/05/2026M00242727-I1Request digital key ↗
09/05/2026M00243613-I1Request digital key ↗
09/04/2026M00395381-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Supported Scaffold2
09/05/2026M00242733-I1Request digital key ↗
09/05/2026M00243619-I1Request digital key ↗
▸DOB NOWPlans/Sketch - General Construction1
09/04/2026M00466994-I1Request digital key ↗
▸Applications & Permits9
▸BISPLAN / WORK APPROVAL APPLICATION5
01/30/2023140956142Open ↗
01/30/2023123912383Open ↗
10/01/2020140956142Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
10/06/2020140956142Open ↗
07/01/2020123912383Open ↗
06/17/2020123912383Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications23
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/05/2026M00243619-I1Open ↗
09/04/2026M00466994-I1Open ↗
08/25/2026M08035175-P2Open ↗
Showing 3 of 10 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT3
10/01/2020140956142Open ↗
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
▸DOB NOWProgress Inspector Seal & Signature3
08/27/2026M00242727-I1Open ↗
08/26/2026M00242733-I1Open ↗
08/24/2026M08035175-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/24/2026M08035175-I1Open ↗
08/24/2026M08035175-I1Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
10/01/2020140956142Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
06/17/2020123912383Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/01/2020140956142Open ↗
▸Safety & Tenant Protection8
▸DOB NOWTenant Protection Plan5
08/13/2026M00242727-I1Open ↗
08/13/2026M00243613-I1Open ↗
08/13/2026M00243619-I1Open ↗
Showing 3 of 5 on file for this type
▸BISTenant Protection Plan and Notes3
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
10/01/2020140956142Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
09/04/2026M00466994-I1Open ↗
08/25/2026M08035175-P1Open ↗
08/25/2026M08035175-P2Open ↗
Showing 3 of 5 on file for this type
▸BISASBESTOS: CERTIFICATION (DEP ACP5)3
10/01/2020140956142Open ↗
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
▸Energy Compliance10
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
▸BISAIR SEALING AND INSULATION - VISUAL2
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸BISENERGY CODE COMPLIANCE INSPECTIONS2
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)2
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
10/01/2020140956142Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
10/01/2020140956142Open ↗
▸Inspections & Test Reports9
▸BISSTRUCTURAL STABILITY - ALTERATIONS OF EXISTING BUILDINGS2
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸BISFIRE-RESISTANT PENETRATIONS AND JOINTS (FIRESTOP)2
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸BISMASONRY2
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸BISCONCRETE - CAST-IN-PLACE1
01/27/2023123912383Open ↗
▸BISTECHNICAL REPORT: PILE DRIVING1
06/08/2020123912383Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
10/01/2020140956142Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
07/01/2020123912383Open ↗
06/04/2020123912383Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
01/30/2023140956142Open ↗
01/27/2023123912383Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT3
10/01/2020140956142Open ↗
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW32
01/27/2023140956142Open ↗
01/27/2023123912383Open ↗
▸Filing & Intake Forms9
▸BISBOROUGH INTAKE FORM5
07/01/2020123912383Open ↗
06/17/2020123912383Open ↗
06/12/2020123912383Open ↗
Showing 3 of 5 on file for this type
▸BISADDITIONAL INFORMATION2
06/17/2020123912383Open ↗
06/08/2020123912383Open ↗
▸BISEFILING COVER SHEET1
05/15/2020123912383Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/01/2020140956142Open ↗
▸Other Documents1
▸DOB NOWDHCR Document1
08/13/2026M00614475-I1Open ↗