← Back
Two family brick
1316 PLIMPTON AVENUE
BRONX · BIN 2003355
💬 Discuss this project
1930Year Built
2Stories
B1Building Class
R7-1Zoning
2,226 sfGross Floor Area
2Units
0 Open Violations
Two family brick · Owner of record: 1316 PLIMPTON LLC · 2,125 sf lot · 1.05 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbingFire Protection
Floor 211p · 1 filing · 20 docs
Floor 111p · 1 filing · 20 docs
Cellar14p · 1 filing · 20 docs
1 job · most recent 08/18/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
08/18/2026Signed-offOWNERS GC NY LLCHeating and Air Conditioning Systems
Heat / Cool
Daikin 2MXM18AVJU9 19,000 BTU · Condensing Unit ×12
RXF12BVJU9 13,500 BTU · Condensing Unit ×6
1 job · most recent 08/18/2026
Sprinkler System
FiledStatusContractorScope
08/18/2026Signed-offTARGET PIPING NY LLCSprinkler System
1 job · most recent 08/18/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/18/2026Signed-offA M B MECHANICAL INCGas, Storm, Water/Sanitary
2 jobs · most recent 09/04/2025
General Wiring
FiledStatusContractorScope
09/04/2025CompletePOWER DIRECT ELECTRIC INCGeneral Wiring
05/12/2025CompletePOWER DIRECT ELECTRIC INC—
1 job · most recent 08/18/2026
Steel Concrete
FiledStatusContractorScope
08/18/2026Signed-offOWNERS GC NY LLCSteel, Concrete
Building Lifecycle
All (99)Filed (12)Permit Issued (6)Signed Off (3)Violation (3)Inspection (13)Objection (32)Special Inspection (30)
08/18/2026
Filed — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-A2
04/30/2026
Violation issued (HPD, closed)
A
03/20/2026
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
03/20/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
03/20/2026
Special inspection requirement — Interior lighting power
Shahrish Shuvo
03/20/2026
Special inspection requirement — Fenestration areas
Shahrish Shuvo
03/20/2026
Special inspection requirement — Protection of exposed foundation insulation
Shahrish Shuvo
03/20/2026
Special inspection requirement — Air barrier - visual inspection
Shahrish Shuvo
03/20/2026
Special inspection requirement — Energy Code Compliance Inspections
Shahrish Shuvo
03/20/2026
Special inspection requirement — Fenestration air leakage
Shahrish Shuvo
03/20/2026
Special inspection requirement — Metering
Shahrish Shuvo
03/20/2026
Special inspection requirement — Permanent certificate
Shahrish Shuvo
03/20/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
03/20/2026
Special inspection requirement — Maintenance information
Shahrish Shuvo
03/20/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Shahrish Shuvo
03/20/2026
Special inspection requirement — Fire-Resistance Rated Construction
Shahrish Shuvo
03/18/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/18/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
03/12/2026
Filed — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-A1
03/09/2026
Special inspection requirement — Protection of exposed foundation insulation
Shahrish Shuvo
03/09/2026
Special inspection requirement — Fenestration areas
Shahrish Shuvo
03/09/2026
Special inspection requirement — Energy Code Compliance Inspections
Shahrish Shuvo
03/09/2026
Special inspection requirement — Fire-Resistance Rated Construction
Shahrish Shuvo
03/09/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
Shahrish Shuvo
03/09/2026
Special inspection requirement — Permanent certificate
Shahrish Shuvo
03/09/2026
Special inspection requirement — Air barrier - visual inspection
Shahrish Shuvo
03/09/2026
Special inspection requirement — Interior lighting power
Shahrish Shuvo
03/09/2026
Special inspection requirement — Maintenance information
Shahrish Shuvo
03/09/2026
Special inspection requirement — Metering
Shahrish Shuvo
03/09/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
Shahrish Shuvo
03/09/2026
Special inspection requirement — Fenestration air leakage
Shahrish Shuvo
03/09/2026
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
02/05/2026
Signed off — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-S3
02/03/2026
Permit issued — Structural
X01182332-S3-ST
12/21/2025
Objection resolved — Addressed
12/12/2025
Objection raised — Admin
12/05/2025
Filed — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-S3
12/04/2025
Special inspection requirement — Final
Shahrish Shuvo
12/04/2025
Special inspection requirement — Structural Steel - Details
Shahrish Shuvo
12/04/2025
Special inspection requirement — Structural Cold-Formed Steel
Shahrish Shuvo
12/04/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
Shahrish Shuvo
12/01/2025
Signed off — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-S2
11/17/2025
Signed off — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-S1
10/27/2025
Inspection — Pass-Final SP - Up to 3 Requested Floors
Pass
View inspection ↗
10/16/2025
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
10/03/2025
Objection resolved — Addressed
10/03/2025
Objection resolved — Addressed
10/03/2025
Objection resolved — Addressed
10/03/2025
Objection resolved — Addressed
09/24/2025
Objection raised — Admin
09/24/2025
Objection raised — Fire_Protection
09/24/2025
Objection raised — Fire_Protection
09/24/2025
Objection raised — Fire_Protection
09/22/2025
Objection resolved — Addressed
09/22/2025
Objection resolved — Addressed
09/12/2025
Filed — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-P9
09/11/2025
Objection raised — Admin
09/11/2025
Objection raised — Admin
09/10/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
09/09/2025
Filed — Alteration CO
PLUMBING & SPRINKLER SPECIFICATIONS FILED IN CONJUNCTION WITH GC APPLICATION X01182332-I1
X01182332-P8
Latest 60 of 99 events.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
AY CONSULTING3109/13/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/06/2025$850K—Private party → 1316 PLIMPTON LLC$382/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LEANDRO NILS DICKSON ARCHITECT, LLC508/18/2026
AG ENGINEERING PLLC112/05/2025
BORIS BALKHIYEV, PE609/12/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1603/21/2026
REDCUT EXPEDITING303/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
OWNERS GC NY LLCGeneral Contractor507/08/2026
TARGET PIPING NY LLCFire Protection107/08/2026
B&B MECH PLBG & HTG LLCPlumbing107/08/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SHAHRISH SHUVO ENGINEERIN8524508/18/2026
AG ENGINEERING PLLC8899709/12/2025
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offOWNERS GC NY LLC02/03/2026
DOB NOWMechanical SystemsSigned-offOWNERS GC NY LLC06/11/2025
DOB NOWSprinklersSigned-offTARGET PIPING NY LLC06/05/2025
DOB NOWGeneral ConstructionPermit IssuedOWNERS GC NY LLC06/02/2025
DOB NOWSprinklersSigned-offPRIME PIPING & HEATING IN05/20/2025
DOB NOWPlumbingSigned-offTARGET PIPING NY LLC05/19/2025
▾Field Inspections (DOB CAP) — 13
DateTypeResultReport
03/20/2026Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
03/18/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
03/18/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
10/27/2025Pass-Final SP - Up to 3 Requested FloorsPassView ↗
10/16/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/10/2025Pass-Final CND-Occupancy InspectionPassView ↗
09/03/2025Fail-Final SP - Up to 9 Requested FloorsFailView ↗
08/26/2025Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
08/15/2025Pass-Final CND-Occupancy InspectionPassView ↗
06/17/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
06/17/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/23/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/23/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 75
DateRequirementInspectorRole
03/20/2026Fenestration and door U-factor and product ratingsShahrish Shuvoenergy_progress
03/20/2026MeteringShahrish Shuvoenergy_progress
03/20/2026Interior lighting powerShahrish Shuvoenergy_progress
03/20/2026Permanent certificateShahrish Shuvoenergy_progress
03/20/2026Fenestration areasShahrish Shuvoenergy_progress
03/20/2026Fire-Resistant Penetrations and JointsShahrish Shuvospecial
03/20/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
03/20/2026Fire-Resistance Rated ConstructionShahrish Shuvoprogress
03/20/2026Energy Code Compliance InspectionsShahrish Shuvoprogress
03/20/2026Air barrier - visual inspectionShahrish Shuvoenergy_progress
03/20/2026Fenestration air leakageShahrish Shuvoenergy_progress
03/20/2026Protection of exposed foundation insulationShahrish Shuvoenergy_progress
03/20/2026Maintenance informationShahrish Shuvoenergy_progress
03/09/2026Structural Stability – Alterations of existing buildingsShahrish Shuvospecial
03/09/2026Permanent certificateShahrish Shuvoenergy_progress
03/09/2026Fenestration areasShahrish Shuvoenergy_progress
03/09/2026Fenestration air leakageShahrish Shuvoenergy_progress
03/09/2026Interior lighting powerShahrish Shuvoenergy_progress
03/09/2026MeteringShahrish Shuvoenergy_progress
03/09/2026Fenestration and door U-factor and product ratingsShahrish Shuvoenergy_progress
03/09/2026Protection of exposed foundation insulationShahrish Shuvoenergy_progress
03/09/2026Fire-Resistance Rated ConstructionShahrish Shuvoprogress
03/09/2026Energy Code Compliance InspectionsShahrish Shuvoprogress
03/09/2026Fire-Resistant Penetrations and JointsShahrish Shuvospecial
03/09/2026Air barrier - visual inspectionShahrish Shuvoenergy_progress
Latest 25 of 75.
▾Documents — 72 on file (BIS + DOB NOW)
▸Plans & Drawings12
▸DOB NOWPlans/Sketch12
08/18/2026X01182332-P4Request digital key ↗
08/18/2026X01182332-P1Request digital key ↗
08/18/2026X01182332-S2Request digital key ↗
Showing 3 of 12 on file for this type
▸Seals & Professional Certifications34
▸DOB NOWProgress Inspector Seal & Signature13
09/02/2026X01182332-P9Open ↗
08/29/2026X01182332-A1Open ↗
08/29/2026X01182332-A1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature12
08/18/2026X01182332-P1Open ↗
08/18/2026X01182332-S2Open ↗
08/18/2026X01182332-S1Open ↗
Showing 3 of 12 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature9
09/02/2026X01182332-P9Open ↗
08/29/2026X01182332-A1Open ↗
08/29/2026X01182332-P1Open ↗
Showing 3 of 9 on file for this type
▸Safety & Tenant Protection8
▸DOB NOWStreet Tree Checklist5
08/18/2026X01182332-A2Open ↗
08/13/2026X01182332-P1Open ↗
08/13/2026X01182332-A1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWStreet Tree Sign Off1
08/13/2026X01182332-I1Open ↗
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/13/2026X01182332-I1Open ↗
▸DOB NOWStreet Trees Site Plan1
08/13/2026X01182332-I1Open ↗
▸Environmental & Asbestos12
▸DOB NOWDEP ACP-5: Asbestos Assessment Report12
08/18/2026X01182332-P1Open ↗
08/18/2026X01182332-S2Open ↗
08/18/2026X01182332-S1Open ↗
Showing 3 of 12 on file for this type
▸Other Documents6
▸DOB NOWProperty Ownership Certification5
08/18/2026X01182332-P1Open ↗
08/18/2026X01182332-I1Open ↗
08/18/2026X01182332-A2Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWFinal Survey1
08/13/2026X01182332-I1Open ↗