← Back
Two stories - detached, small or mid-size
132-12 133 AVENUE
QUEENS · South Ozone Park · BIN 4610751
💬 Discuss this project
1925Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,597 sfGross Floor Area
1Units
5 Open Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · 4,000 sf lot · 0.4 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
ANVEER PROPERTIES703/22/2026
OAMS ARCHITECTURAL DESIGN P403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
OAMS ARCHITECTURAL DESIGN P.L.L.C.411/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
OAMS ARCHITECTURAL DESIGN803/21/2026
Building Lifecycle
All (42)Filed (4)Violation (2)Objection (24)Special Inspection (12)
01/15/2026
Violation issued (ECB, open)
Construction
12/16/2024
Objection resolved — Addressed
12/16/2024
Objection resolved — Addressed
11/27/2024
Objection resolved — Addressed
11/25/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
New curb cut installation. No change in use, egress, occupancy or bulk.
Q01121033-S1
11/20/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
11/20/2024
Objection resolved — Addressed
11/18/2024
Objection resolved — Addressed
10/18/2024
Objection raised — Inspections
10/18/2024
Objection raised — Scope
10/18/2024
Objection raised — Zoning
10/18/2024
Objection raised — Zoning
10/18/2024
Objection raised — Structural
10/18/2024
Objection raised — Inspections
10/16/2024
Objection raised — Zoning
10/16/2024
Objection raised — Scope
10/16/2024
Objection raised — Structural
10/16/2024
Objection raised — Structural
10/16/2024
Objection raised — Structural
10/11/2024
Objection raised — Other
10/11/2024
Objection resolved — Addressed
10/09/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
New curb cut installation. No change in use, egress, occupancy or bulk.
Q01121033-S2
10/07/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
New curb cut installation. No change in use, egress, occupancy or bulk.
Q01121033-S3
10/07/2024
Filed — ALT-CO - New Building with Existing Elements to Remain
New curb cut installation. No change in use, egress, occupancy or bulk.
Q01121033-I1
10/02/2024
Special inspection requirement — Masonry
10/02/2024
Special inspection requirement — Concrete - Cast-In-Place
10/02/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/02/2024
Special inspection requirement — Structural Steel - Details
10/02/2024
Special inspection requirement — Subgrade Inspections
10/02/2024
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
10/02/2024
Special inspection requirement — Final
10/02/2024
Special inspection requirement — Footing and Foundation
10/02/2024
Special inspection requirement — Fire-Resistance Rated Construction
10/02/2024
Special inspection requirement — Structural Wood Frame
10/02/2024
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
10/02/2024
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
08/05/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Nothing on file for this building.
1 project · most recent 11/25/2024
Storm
FiledStatusContractorScope
11/25/2024——Storm
1 project · most recent 11/25/2024
Masonry Wood
FiledStatusContractorScope
11/25/2024——Masonry, Wood
1 project · most recent 11/25/2024
Fence
FiledStatusContractorScope
11/25/2024——Fence
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
10/02/2024Masonry—special
10/02/2024Concrete - Cast-In-Place—special
10/02/2024Fire-Resistant Penetrations and Joints—special
10/02/2024Structural Steel - Details—special
10/02/2024Subgrade Inspections—special
10/02/2024Subsurface Conditions – Fill Placement & In-Place Density—special
10/02/2024Final—progress
10/02/2024Footing and Foundation—progress
10/02/2024Fire-Resistance Rated Construction—progress
10/02/2024Structural Wood Frame—progress
10/02/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
10/02/2024Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities—special
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/21/2026Q01121033-S1Request digital key ↗
08/15/2026Q01121033-S2Request digital key ↗
08/15/2026Q01121033-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications4
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/21/2026Q01121033-I1Open ↗
08/21/2026Q01121033-S3Open ↗
08/21/2026Q01121033-S2Open ↗
Showing 3 of 4 on file for this type
▸Other Documents2
▸DOB NOWProperty Ownership Certification1
08/15/2026Q01121033-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/15/2026Q01121033-I1Open ↗