HPD02/01/2011SECTION 27-2005 ADMIN. CODE: REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER KEY OPERATED LOCK AT ENTRANCE DOOR TO BUILDING AT PUBLIC HALL, 1st STORY
HPD02/01/2011SECTION 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 2NDFL, 2nd STORY
ECB01/14/2026BC 3308.5 INADEQUATE VERTICAL NETTING/CABLE SYSTEM ON SEVERAL FLOORS @ EXPO1 & 3. LOOSE VERTICAL DEBRIS NETTING NOT ADEQUATELY SECURED, NOT PREVENTING DEBRIS FROM FALLING OFF SITE. ZERO CABLE NOT ADEQUATELY TENNothing owed — awaiting certificate of correction
ECB12/20/2025AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. 3RD FLOOR LEVEL SLAB NEEDLE BEAM INSTALLED AT EXPOSE 3 WORK DOES NOT CONFIRM AS PER PLAN. MISSING SHORING POSTS AND LOCATIONS. CREATED UNSAFE CONDITIONS FOR USE NNothing owed — awaiting certificate of correction
ECB12/20/2025FAILURE TO PROVIDE ADEQUATE SITE SAFETY PLAN. AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. UPON REQUEST FOR REVIEW SSP DOES NOT PROVIDE NEEDLE BEAM AT EXPOSURE 2. STOP ALL USE OF NEEDLE BEAM WITH SCAFFOLD. PNothing owed — awaiting certificate of correction
ECB12/20/2025AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. I OBSERVED UNSAFE STORAGE AREA PROVIDE ON STREET DOES NOT MAINTAIN. CREATED AN UNSAFE CONDITION FOR PEDESTRIAN PASSING THE JOB SITE UNDER SIDEWALK SHED. COMPLY WINothing owed — awaiting certificate of correction
ECB12/20/2025AT TIME OF INSPECTION OBSERVED ACTIVE JOB SITE. UPON REQUEST FOR APPROVED SCAFFOLD PLAN, SST CARD FOR COMPETENT PERSON UNABLE TO PROVIDE. PROVIDE ALL DOCUMENT ON SITE AS REQUIRE. COMPLY WITH CODE. PROVIDE REQUIHearing held — result not yet published$2K proposed
ECB12/20/2025FAILURE TO MAINTAIN SUPPORTED PIPE SCAFFOLD. AT TIME OF INSPECTION OBSERVED SUPPORTED POPE SCAFFOLD INSTALLED AT ALL EXPOSE UP TO ROOF LEVEL WITH NOT MAINTAIN AS REQUIRED. SCAFFOLD MISSING NETTING, UNSAFE PLATFNothing owed — awaiting certificate of correction
ECB12/20/2025FAILURE TO PROVIDE ADEQUATE SAFETY MEASURE FOR ALL PERSONS. NEEDLE BEAM INSTALLED ON STAIRS LOBBY VERY CLOSED TO STEPS CREATED A TRIPPED HAZARD CONDITIONS. STOP USE OF EGRESS AT 3RD TO 4 FLOOR LEVEL. PROVIDE SANothing owed — awaiting certificate of correction
ECB07/19/2025OBSERVER JERSEY BARRIERS INSTALLED AT EXP# 1 NOT AS PER MANUFACTURE SPECIFICATION. JERSEY BARRIERS SEVERAL NOT INTERLOCKED AND NOT FILLED WITH SAND/WATER WHICH POSING A POTENTIAL HAZARD BY ALLOWING UNINTENDNothing owed — awaiting certificate of correction
ECB07/19/20257 STORIES NB INACTIVE JOBSITE, WITH A BUILDING FOOTPRINT (SQ. FT.) 10413, WALK JOBSITE PERIMETERS, KNOCK & CALLED OUT, I OBSERVED NO COMPETENT WATCH PERSONNEL AS PER BC 3303.7.7.6 A WATCHPERSON REQUIREMENTS OFNothing owed — awaiting certificate of correction
ECB03/18/20253304.4.5 PLACING OF SOIL OR FOUNDATION WORK EQUIPMENT AND EXCAVATED MATERIAL. OBSERVED HEAVY MACHINE EXCAVATOR OPERATING ON TOP OF A MOUND OF UNCOMPACTED EXCAVATED SOIL WITHOUT DESIGNS W/ CALCULATION LOADS FORNothing owed — awaiting certificate of correction
ECB08/31/2010WORK DOES NOT CONFORM TO APPROVED CONSTRUCTION DOCUMENTS AND/OR APPROVED AMENDMENTS FOR THIS PROCERT JOB DWG 2/4/09 NOTED AT CELLAR PLAN PROPOSES 2HR FIRED RATED ENCLOSURE W/ FPSC DOORS AT BOILER ROOM FOUND WALNothing owed — awaiting certificate of correction