← Back
One story - permanent living quarter
132-40 57 ROAD
QUEENS · BIN 4139114
💬 Discuss this project
1960Year Built
1Stories
A2Building Class
R4-1Zoning
1,296 sfGross Floor Area
1Units
One story - permanent living quarter · 3,000 sf lot · 0.43 FAR built · Flood zone X
Locations of Work
Architecture
Roof1p · 1 filing · 6 docs
Floor 11p · 1 filing · 6 docs
Nothing on file for this building.
Building Lifecycle
All (11)Filed (1)Permit Issued (1)Signed Off (1)Objection (4)Special Inspection (4)
08/08/2025
Signed off — Alteration
Filing application for Lintel Replacement and Masonry Spot Pointing as per plans file herewith. There is no change of use, egress, or occupancy under this application.
Q01017792-I1
05/08/2025
Permit issued — General Construction
Q01017792-I1-GC
10/24/2024
Objection resolved — Addressed
07/11/2024
Objection resolved — Addressed
07/09/2024
Objection raised — Other
07/09/2024
Objection raised — Cost
06/25/2024
Filed — Alteration
Filing application for Lintel Replacement and Masonry Spot Pointing as per plans file herewith. There is no change of use, egress, or occupancy under this application.
Q01017792-I1
06/24/2024
Special inspection requirement — Tenant Protection Plan Compliance
EUGENE BIFULCO
03/12/2024
Special inspection requirement — Masonry
EUGENE BIFULCO
03/12/2024
Special inspection requirement — Structural Stability – Alterations of existing buildings
EUGENE BIFULCO
03/12/2024
Special inspection requirement — Final
EUGENE BIFULCO
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/18/2020$895K—Private party → Private party$691/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ENGINEERED BUILDING INSPECTIONS, P.106/25/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BOCCIA INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CROSSCHECK INSPECTION SER544206/25/2024
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offWACLAW ZAREBA05/08/2025
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
06/24/2024Tenant Protection Plan ComplianceEUGENE BIFULCOspecial
03/12/2024MasonryEUGENE BIFULCOspecial
03/12/2024Structural Stability – Alterations of existing buildingsEUGENE BIFULCOspecial
03/12/2024FinalEUGENE BIFULCOprogress
▾Documents — 6 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/22/2026Q01017792-I1Request digital key ↗
▸Seals & Professional Certifications4
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026Q01017792-I1Open ↗
08/26/2026Q01017792-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026Q01017792-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
08/26/2026Q01017792-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026Q01017792-I1Open ↗