Over six families without stores
132 6 AVENUE
BROOKLYN · BIN 3019225
💬 Discuss this project
1876Year Built
4Stories
C1Building Class
R6BZoning
5,157 sfGross Floor Area
7Units
Rent Stabilized2 Open Violations ▸FDNY Report ↗
Over six families without stores · Owner of record: 132 6TH OWNER LLC · 1,800 sf lot · 2.87 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
Roof11p · 1 filing · 20 docs
Floor 4Under Construction8p · 2 filings · 20 docs
Floor 3Under Construction5p · 1 filing · 3 docs
Floor 2Under Construction5p · 1 filing · 3 docs
Floor 1Under Construction5p · 1 filing · 3 docs
Cellar7p · 1 filing · 20 docs
Basement1p · 1 filing · 20 docs
Sub-BasementUnder Construction5p · 1 filing · 3 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
DNA1209/13/2026
J G CONSTRUCTION SRVCS608/29/2026
VARIES303/22/2026
132 6TH OWNER LLC103/22/2026
92 LEXINGTON ROYAL103/22/2026
132 6TH AVENUE HOLDINGS1003/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/16/2025$5.0M—132 6TH AVENUE HOLDINGS LLC → 132 6TH OWNER LLC$960/sf building
12/04/2018$3.0M—Private party → 132 6TH AVENUE HOLDINGS LLC$582/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TAREK M. ZEID, PE, PLLC104/20/2026
COLBERG ARCHITECTURE204/16/2026
FLORINELA MURESAN403/18/2026
ASHRAF CORP203/17/2026
TVG LLC109/13/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JAM CONSULTANTS, INC.803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
J & G CONSTRUCTION SVCSGeneral Contractor306/27/2026
PRIME BUILDERS NY LLCGeneral Contractor308/22/2026
LENS ELECTRIC, INCElectrical203/22/2026
T&D NY CONSTRUCTION CORPGeneral Contractor203/21/2026
GO GREENER PLUMBING LLCFire Protection107/08/2026
GO GREENER PLUMBING LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CONCRETE SOLUTIONS LAB CO5344704/20/2026
Building Lifecycle
All (136)Filed (10)Permit Issued (9)Signed Off (3)Violation (13)Inspection (7)Objection (80)Special Inspection (14)
07/23/2026
Permit issued — Mechanical Systems
B01250902-S1-MS
07/23/2026
Permit issued — Structural
B01250902-S3-ST
07/09/2026
Signed off — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. LIVE LOAD 300PSF.
B01367105-I1
07/09/2026
Signed off — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01367106-I1
06/23/2026
Permit issued — Sidewalk Shed
B01367105-I1-SH
06/16/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/16/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
06/03/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MINA HANNA
06/03/2026
Special inspection requirement — Final
MINA HANNA
06/03/2026
Special inspection requirement — Fire-Resistance Rated Construction
MINA HANNA
04/30/2026
Violation issued (HPD, open)
A
04/29/2026
Objection raised — Admin
04/29/2026
Objection resolved — Resolved
04/29/2026
Objection raised — Admin
04/29/2026
Objection resolved — Resolved
04/20/2026
Filed — Alteration
PROPOSED ROOFTOP DUNNAGE & BASEMENT LINTEL. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B01250902-S3
04/16/2026
Filed — Alteration
PROPOSED ROOFTOP DUNNAGE & BASEMENT LINTEL. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B01250902-P1
04/16/2026
Special inspection requirement — Masonry
MINA HANNA
04/10/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MINA HANNA
03/26/2026
Special inspection requirement — Post-installed Anchors
MINA HANNA
03/20/2026
Permit issued — Supported Scaffold
B01367106-I1-SF
03/18/2026
Filed — Alteration
PROPOSED ROOFTOP DUNNAGE & BASEMENT LINTEL. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B01250902-P2
03/18/2026
Permit issued — Sidewalk Shed
B01367105-I1-SH
03/17/2026
Filed — Alteration
INSTALLATION OF TEMPORARY HEAVY DUTY SIDEWALK SHED AS PER PLANS. NO CHANGE IN USE, EGRESS OR OCCUPANCY. SIDEWALK SHED SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. LIVE LOAD 300PSF.
B01367105-I1
03/17/2026
Filed — Alteration
PROPOSED INSTALLATION OF TEMPORARY PIPE SCAFFOLD AS PER PLANS. WORK SHALL COMPLY WITH CHAPTER #33 OF 2022 THE NYC BUILDING CODE. NO CHANGE IN USE, OCCUPANCY, OR EGRESS UNDER THIS APPLICATION.
B01367106-I1
03/13/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/04/2026
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
02/13/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
02/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
MINA HANNA
02/04/2026
Special inspection requirement — Fire-Resistance Rated Construction
MINA HANNA
02/04/2026
Special inspection requirement — Final
MINA HANNA
01/28/2026
Permit issued — Sprinklers
B01250941-I1-EW-SP
01/28/2026
Permit issued — Plumbing
B01250902-S2-PL
12/30/2025
Special inspection requirement — Structural Steel - High Strength Bolting
MINA HANNA
12/30/2025
Special inspection requirement — Structural Steel - Welding
MINA HANNA
12/05/2025
Permit issued — General Construction
B01250902-I1-GC
12/02/2025
Special inspection requirement — Final
MINA HANNA
11/19/2025
Violation issued (HPD, open)
I
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/20/2025
Objection resolved — Addressed
10/17/2025
Objection resolved — Addressed
10/17/2025
Objection resolved — Addressed
10/16/2025
Objection resolved — Addressed
10/15/2025
Objection raised — Mechanical
10/15/2025
Objection raised — Mechanical
10/15/2025
Objection raised — Mechanical
10/15/2025
Objection raised — Mechanical
10/15/2025
Objection raised — Cost
10/15/2025
Objection resolved — Addressed
10/15/2025
Objection resolved — Addressed
10/09/2025
Objection raised — Scope
10/09/2025
Objection raised — Structural
10/09/2025
Objection raised — Scope
10/09/2025
Objection raised — Structural
10/08/2025
Filed — Alteration
Modifications to existing Sprinkler system per plans filed.
B01250941-I1
10/08/2025
Filed — Alteration
PROPOSED ROOFTOP DUNNAGE & BASEMENT LINTEL. NO CHANGE OF USE, EGRESS OR OCCUPANCY.
B01250902-S1
10/06/2025
Objection resolved — Addressed
Latest 60 of 136 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWMechanical SystemsSigned-offPRIME BUILDERS NY LLC07/23/2026
DOB NOWStructuralSigned-offPRIME BUILDERS NY LLC07/23/2026
DOB NOWSidewalk ShedSigned-offJ & G CONSTRUCTION SVCS06/23/2026
DOB NOWSupported ScaffoldSigned-offJ & G CONSTRUCTION SVCS03/20/2026
DOB NOWSidewalk ShedSigned-offJ & G CONSTRUCTION SVCS03/18/2026
DOB NOWSprinklersPermit IssuedGO GREENER PLUMBING LLC01/28/2026
DOB NOWPlumbingSigned-offGO GREENER PLUMBING LLC01/28/2026
DOB NOWGeneral ConstructionSigned-offPRIME BUILDERS NY LLC12/05/2025
DOB NOWConstruction FenceSigned-offB G NATIONAL PLG & HTG IN09/16/2019
BISPLISSUEDSTARLITE PLBG & HTG CORP12/16/2020
BIS—ISSUEDT&D NY CONSTRUCTION CORP06/30/2020
BISPLISSUEDSTARLITE PLBG & HTG CORP12/19/2019
1 project · most recent 04/20/2026
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
04/20/2026Signed-offPRIME BUILDERS NY LLCAir Conditioning Systems
Cooling
Lg ZRNU073MAAA 7,500 BTU · Vrf Indoor ×4
ZRUM036GSS0 36,000 BTU · Vrf Outdoor ×4
ZRNU093SJSA 9,600 BTU · Vrf Indoor ×2
ZRNU123MAAA 12,300 BTU · Vrf Indoor ×2
ZRNU53SJSA 5,500 BTU · Vrf Indoor ×2
ZRNU123NAAA 12,000 BTU · Vrf Indoor ×1
ZRUM048GSS0 48,000 BTU · Vrf Outdoor ×1
1 project · most recent 10/08/2025
FiledStatusContractorScope
10/08/2025Permit IssuedGO GREENER PLUMBING LLC14 heads
1 project · most recent 04/20/2026
Water/Sanitary
FiledStatusContractorScope
04/20/2026Signed-offGO GREENER PLUMBING LLCWater/Sanitary
4 projects · most recent 03/10/2026
General Wiring
FiledStatusContractorScope
03/10/2026CompleteRICHARD NEU—
12/17/2025Permit IssuedOMD ELECTRICAL CORPGeneral Wiring
07/26/2020CompleteLENS ELECTRIC, INCGeneral Wiring
11/26/2019CompleteLENS ELECTRIC, INC—
1 project · most recent 04/20/2026
Masonry
FiledStatusContractorScope
04/20/2026Signed-offPRIME BUILDERS NY LLCMasonry
1 project · most recent 03/17/2026
Scaffold
FiledStatusContractorScope
03/17/2026Signed-offJ & G CONSTRUCTION SVCSScaffold
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
06/16/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/16/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
06/16/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/10/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/13/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/04/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
03/04/2026Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
02/13/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
06/10/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 14
DateRequirementInspectorRole
06/03/2026Fire-Resistant Penetrations and JointsMINA HANNAspecial
06/03/2026FinalMINA HANNAprogress
06/03/2026Fire-Resistance Rated ConstructionMINA HANNAprogress
04/16/2026MasonryMINA HANNAspecial
03/26/2026Fire-Resistant Penetrations and JointsMINA HANNAspecial
03/26/2026Post-installed AnchorsMINA HANNAspecial
02/04/2026Fire-Resistant Penetrations and JointsMINA HANNAspecial
02/04/2026Fire-Resistance Rated ConstructionMINA HANNAprogress
02/04/2026FinalMINA HANNAprogress
12/30/2025Structural Steel - High Strength BoltingMINA HANNAspecial
12/30/2025Structural Steel - WeldingMINA HANNAspecial
12/02/2025FinalMINA HANNAprogress
07/03/2025FinalMINA HANNAprogress
07/03/2025Mechanical SystemsMINA HANNAspecial
▾Documents — 114 on file (BIS + DOB NOW)
▸Plans & Drawings10
▸DOB NOWPlans/Sketch9
09/03/2026B01367106-I1Request digital key ↗
08/17/2026B01367105-I1Request digital key ↗
08/17/2026B01250902-I1Request digital key ↗
Showing 3 of 9 on file for this type
▸DOB NOWPlans/Sketch - Construction Fence1
09/02/2026B00228061-I1Request digital key ↗
▸Applications & Permits16
▸DOB NOWLPC Approval/Permit6
08/17/2026B01250902-S3Open ↗
08/17/2026B01250902-I1Open ↗
08/13/2026B01250902-S2Open ↗
Showing 3 of 6 on file for this type
▸BISPLAN / WORK APPROVAL APPLICATION5
11/18/2020321385899Open ↗
12/16/2019321924325Open ↗
02/07/2019321924325Open ↗
Showing 3 of 5 on file for this type
▸BISWORK PERMIT APPLICATION4
12/26/2019321385899Open ↗
12/26/2019321385899Open ↗
12/26/2019321385899Open ↗
Showing 3 of 4 on file for this type
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
11/08/2020321385899Open ↗
▸Zoning, Tax Lot & Property Records2
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
03/26/2021321385899Open ↗
▸BISZONING DIAGRAM1
03/01/2019321385899Open ↗
▸Seals & Professional Certifications24
▸DOB NOWDPL-1: Design Professional Seal & Signature10
09/03/2026B01367106-I1Open ↗
08/17/2026B01367105-I1Open ↗
08/17/2026B01250902-P2Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026B01250902-I1Open ↗
08/29/2026B01250902-S1Open ↗
08/28/2026B01250902-S2Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026B01250902-I1Open ↗
09/01/2026B01250902-I1Open ↗
08/29/2026B01250902-S1Open ↗
Showing 3 of 6 on file for this type
▸Trade Schedules & Equipment7
▸BISSCHEDULE B - PLUMBING2
11/18/2020321385899Open ↗
03/01/2019321385899Open ↗
▸BISFA - FDNY APPROVAL : FD-FAA2
03/26/2021321385899Open ↗
03/16/2021321924325Open ↗
▸BISEQUIPMENT USE APPLICATION/PERMIT1
03/26/2021321385899Open ↗
▸BISEQUIPMENT USE PERMITS1
03/26/2021321385899Open ↗
▸BISDETECTOR:SMOKE-CERT. OF INSTALLATION1
01/25/2021321385899Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
03/01/2019321385899Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
03/01/2019321385899Open ↗
▸Environmental & Asbestos8
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/17/2026B01250902-P2Open ↗
08/17/2026B01250902-P1Open ↗
08/17/2026B01250902-S3Open ↗
Showing 3 of 7 on file for this type
▸BISDEP ASBESTOS PROJECT COMPLETION FORM1
09/20/2019321385899Open ↗
▸Energy Compliance4
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
01/25/2021321385899Open ↗
01/25/2021321385899Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
09/20/2019321385899Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
03/26/2021321385899Open ↗
▸Inspections & Test Reports10
▸BISTECHNICAL REPORT: RESPONSIBILITY9
03/26/2021321385899Open ↗
03/26/2021321385899Open ↗
01/25/2021321385899Open ↗
Showing 3 of 9 on file for this type
▸BISHYDRO FLOW TEST LETTER1
03/01/2019321385899Open ↗
▸Approvals, Objections & Sign-offs12
▸BISLETTERS - SUPPORTING DOCUMENTATION5
04/07/2021321385899Open ↗
03/01/2019321385899Open ↗
03/01/2019321385899Open ↗
Showing 3 of 5 on file for this type
▸BISSCHEDULE A - OCCUPANCY / USE2
03/01/2019321385899Open ↗
03/01/2019321385899Open ↗
▸DOB NOWLandmark Approval2
08/13/2026B01250902-S3Open ↗
08/13/2026B01250902-I1Open ↗
▸BISLANDMARKS APPROVAL1
08/27/2019321385899Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
03/16/2021321924325Open ↗
▸BISLANDMARKS SIGNOFF1
05/27/2021321385899Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT3
03/16/2021321924325Open ↗
03/01/2019321385899Open ↗
02/07/2019321924325Open ↗
▸BISAcord 25 (Acord Certificate of Liability Insurance)1
09/20/2019321385899Open ↗
▸BISPROJECT-SPECIFIC GL INSURANCE1
09/20/2019321385899Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
03/26/2021321385899Open ↗
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION7
03/15/2021321385899Open ↗
01/04/2021321385899Open ↗
01/04/2021321385899Open ↗
Showing 3 of 7 on file for this type
▸BISEFILING COVER SHEET3
02/07/2019321924325Open ↗
01/23/2019321385899Open ↗
01/23/2019321385899Open ↗
▸Other Documents3
▸DOB NOWProof of Historic Building2
08/13/2026B01250902-P1Open ↗
08/13/2026B01250902-I1Open ↗
▸BISPLOT DIAGRAM1
03/01/2019321385899Open ↗