ECB08/11/2026CLASS 2: 1. MAIN LINE BOX COVER CAN BE OPENED WHILE POWER IS ON, FAILING TO PROVIDE REQUIRED SECURED ACCESS. AS PER ASME A17.1 2.26. REMEDY: SECURE MAIN LINE BOX COVER TO PREVENT ACCESS UNDER POWER. 2. WATER AC$625 due
ECB08/11/2026UNAPPROVED/UNSAFE/UNSUITABLE ELECTRICAL EQUIPMENT, APPARATUS, MATERIALS, DEVICES, APPLIANCES OR WIRING IN USE. OBSERVED IN THE REAR CORRIDOR A HUNG ELECTRIC HEATER WITH A FLEX CORD PASSING THRU THE CEILING. IN
ECB08/11/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED HOLE PENETRATIONS THROUGHOUT BUILDING. PREVIOUS VIOLATING # 39156212X., REPAIR AND/REPLACE
ECB08/11/2026FAILURE TO MAINTAIN BUILDING IN CODE-COMPLIANT MANNER. OBSERVED GARBAGE BINS OBSTRUCTING EGRESS PASSAGEWAY. LOCATED THROUGHOUT BUILDING., REPAIR AND/OR REPLACE$1K due
ECB08/11/2026ELECTRICAL WORK WITHOUT A PERMIT. OBSERVED ON THE GROUND FL KITCHEN ELECTRIC OVEN / FOOD WARMER INSTALLED WITH DISCONNECT SW 3/4 PIPE COMING FROM KITCHEN PANEL. CHECKED BIS / DOB NOW NO PERMIT ON FILE ALL WORK
ECB08/11/2026FAILURE TO INSTALL GROUNDING ELECTRODE CONDUCTOR. OBSERVED IN THE MAIN ELECTRICAL RM NO INSTALLATION ON ELECTRODE GROUND ROD ALSO THE MAIN HOUSE WATER GROUND CLAMP IS RUSTED AND THE WATER METER IS NOT JUMPED. A
ECB08/11/2026FAILURE TO PROTECT CONDUCTOR(S) AGAINST OVERCURRENT. OBSERVED IN BOTH ELEVATOR MACHINE RMS THAT THE OVERCURRENT PROTECTION IS INCORRECT BOTH ARE FUSED AT 100 AMP #6 AWG SHALL BE FUSED AT THE PROPER OVERCURRENT
ECB08/11/2026CLASS 2: 1. DROP CEILING SECTION LEADING TO TOP EXIT (ESCAPE HATCH) NOT PROPERLY SECURED FROM TOP OF CAR. AS PER ASME A17.1 2.14. REMEDY: SECURE CEILING SECTION. 2. SEPARATION OF CAR DOORS AT BOTTOM WHILE CAR I$625 due
DOB06/12/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB02/22/2023FAILED TO FILE FISP CYCLE 9B TECHNICAL REPORT BY 2/21/2023
DOB07/31/2018FAILED TO FILE FISP CYCLE 8B TECHNICAL REPORT BY 02/21/2018
DOB05/29/2009V-DOB VIOLATION - ACTIVE
DOB05/29/2009V-DOB VIOLATION - ACTIVE
DOB01/30/2007V-DOB VIOLATION - ACTIVE
DOB10/23/2002V-DOB VIOLATION - ACTIVE
HPD05/10/1987§ 65 M/D LAW PROVIDE UNDER COMPLETED PERMIT, A PROPER ENCLOSURE FOR THE CENTRAL HEATING PLANT, CELLAR REAR EAST.
HPD01/13/1986D26-21.07 ADM CODE PROVIDE 3 EXTRA SPRINKLER HEADS AND SUITABLE WRENCH FOR EMERGENCY PURPOSES AT O.S.Y. VALVE OF SPRINKLER IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT AT 7 STY PUBLIC HALL.
HPD01/13/1986D26-21.07 ADM CODE PROVIDE A PIECE OF GARDEN HOSE 10 FEET IN LENGTH WITH FEMALE COUPLING AND A 10 QUART PAIL ON PREMISES TO TEST SPRINKLER SYSTEM.
HPD01/13/1986D26-21.07 ADM CODE SEAL IN OPEN POSITION THE O.S.Y. VALVE OF THE SPRINKLER SYSTEM IN ACCORDANCE WITH THE RULES AND REGULATIONS OF THIS DEPARTMENT AT 7 STY PUBLIC HALL.
HPD10/15/1984D26-16.01 ADM CODE REPAIR BY CLOSING SO AS TO BE GAS-TIGHT ALL OPENINGS IN THE DISUSED GAS PIPES AT CELLAR CEILINGS THROUGHOUT.
ECB06/25/2026FAILURE TO SUBMIT A CERTIFICATE OF CORRECTION OF VIOLATION #39110398J ISSUED ON 04-01-2024 FOR WORK WITHOUT A PERMIT.(NO PERMIT ON DOB RECORD ), COMPLY WITH COMMISSIONER'S ORDERHearing held — result not yet published
ECB04/01/2024WORK WITHOUT A PERMIT. NOTED ADDITIONAL FLOOR ADDED TO PREMISES. PREMISES ADDED ADDTIONAL FLOOR LABELED PH(PENT HOUSE). PH FLOOR IS ABOVE WHAT IS SUPPOSED TO BE THE 8TH AND TOP FLOOR TO MAKE PREMISES HAVE 9 FLONothing owed — awaiting certificate of correction
ECB04/01/2024OCCUPANCY CONTRARY TO DOB RECORDS. CO #37239 INDICATES PREMISES AS LEGAL 8 STORY BLDG W/CELLAR. NOTED: PREMISES HAS 9 FLOORS W/CELLAR. 9TH FLOOR OR FLOOR LABELED PH(PENT HOUSE) ARE OCCUPIED BY AT LEAST 1 OFFICENothing owed — awaiting certificate of correction
ECB11/03/2022FAILURE TO SUBMIT AN ACCEPTABLE REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL#803046.AGG1 PRIOR NOV#37021414N UNDER 2Nothing owed — awaiting certificate of correction
ECB07/23/2021FAILURE TO SUBMIT ACCEPTABLE REQUIRED CYCLE8B REPORT OF CRITICAL EXAM DOCUMENTING CONDITION OF EXTERIOR WALL&APPURTENANCES REQUIRED BY28-302.4 FOR CONTROL803046.AGG1:PRIOR NOV37013385N UNDER28-302.4 SUBMIT ACCENothing owed — awaiting certificate of correction
ECB02/04/2019FAILURE TO SUBMIT A REQUIRED CYCLE 8B REPORT OF CRITICAL EXAMINATION DOCUMENTING CONDITION OF EXTERIOR WALL AND APPURTENANCES REQUIRED BY 28-302.4 FOR CONTROL# 803046. REMEDY: SUBMIT REQUIRED TECHNICAL REPORT.Nothing owed — awaiting certificate of correction