← Back
Three families
1324 FTELEY AVENUE
BRONX · Soundview-Bruckner-Bronx River · BIN 2027632
💬 Discuss this project
1920Year Built
2Stories
C0Building Class
R6Zoning
3,570 sfGross Floor Area
3Units
Rent Stabilized18 Open Violations ▸
Three families · 2,450 sf lot · 1.46 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 21p · 1 filing · 15 docs
Floor 11p · 1 filing · 15 docs
Sub-Basement1p · 1 filing · 15 docs
Site & exterior1p · 1 filing · 15 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
JX FLAME SOLUTION INC301/09/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
VIBEN BUILDING603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
QMB PLUMBING & HEATING INCPlumbing607/08/2026
Building Lifecycle
All (27)Filed (3)Permit Issued (1)Violation (19)Special Inspection (4)
04/30/2026
Violation issued (HPD, open)
A
11/18/2025
Violation issued (HPD, open)
I
06/05/2025
Violation issued (HPD, open)
A
11/25/2024
Violation issued (HPD, open)
I
04/02/2024
Violation issued (HPD, open)
A
11/16/2023
Violation issued (HPD, open)
I
03/17/2023
Violation issued (HPD, open)
A
11/04/2022
Violation issued (HPD, open)
I
02/17/2022
Violation issued (HPD, open)
A
02/17/2022
Violation issued (HPD, open)
I
01/09/2022
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AT BASEMENT 1ST AND 2ND FLOOR.
X00337644-P2
01/09/2022
Special inspection requirement — HVAC and service water heating equipment
JIE ZHU
01/09/2022
Special inspection requirement — HVAC and service water heating system controls
JIE ZHU
01/03/2022
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AT BASEMENT 1ST AND 2ND FLOOR.
X00337644-P1
01/03/2022
Special inspection requirement — HVAC and service water heating equipment
JIE ZHU
01/03/2022
Special inspection requirement — HVAC and service water heating system controls
JIE ZHU
04/02/2021
Violation issued (HPD, open)
I
04/02/2021
Violation issued (HPD, open)
A
02/23/2021
Permit issued — Plumbing
X00337644-I1-PL
01/28/2021
Filed — Alteration
INSTALL NEW PLUMBING FIXTURES AT BASEMENT 1ST AND 2ND FLOOR.
X00337644-I1
10/28/2019
Violation issued (HPD, open)
I
10/11/2018
Violation issued (HPD, open)
I
11/13/2017
Violation issued (HPD, open)
I
10/28/2016
Violation issued (HPD, open)
I
10/05/2015
Violation issued (HPD, open)
I
02/04/2015
Violation issued (HPD, open)
I
06/02/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offQMB PLUMBING & HEATING INC02/23/2021
BISOTISSUEDJABBIE INDUSTRIES INCORP*01/10/2022
BISOTISSUEDJABBIE INDUSTRIES INCORP*01/29/2021
1 project · most recent 01/09/2022
Gas Water/Sanitary
FiledStatusContractorScope
01/09/2022Signed-offQMB PLUMBING & HEATING INGas, Water/Sanitary
1 project · most recent 03/05/2021
General Wiring
FiledStatusContractorScope
03/05/2021CompleteKJK ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 4
DateRequirementInspectorRole
01/09/2022HVAC and service water heating equipment JIE ZHUenergy_progress
01/09/2022HVAC and service water heating system controls JIE ZHUenergy_progress
01/03/2022HVAC and service water heating equipment JIE ZHUenergy_progress
01/03/2022HVAC and service water heating system controls JIE ZHUenergy_progress
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch - Plumbing3
08/24/2026X00337644-P1Request digital key ↗
08/24/2026X00337644-P2Request digital key ↗
08/24/2026X00337644-I1Request digital key ↗
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
10/05/2021240267028Open ↗
03/25/2020240267028Open ↗
01/13/2020240267028Open ↗
▸BISWORK PERMIT APPLICATION1
01/29/2021240267028Open ↗
▸Seals & Professional Certifications8
▸DOB NOWProgress Inspector Seal & Signature4
09/02/2026X00337644-P1Open ↗
09/02/2026X00337644-P1Open ↗
08/23/2026X00337644-P2Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/13/2026X00337644-P2Open ↗
08/13/2026X00337644-P1Open ↗
08/13/2026X00337644-I1Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
01/13/2020240267028Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/13/2026X00337644-I1Open ↗
08/13/2026X00337644-P1Open ↗
08/13/2026X00337644-P2Open ↗
▸BISASBESTOS: COMPLETION OR CLOSEOUT (ACP20/21/5)1
01/29/2021240267028Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
01/29/2021240267028Open ↗
05/06/2020240267028Open ↗
01/13/2020240267028Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
01/29/2021240267028Open ↗
05/06/2020240267028Open ↗
01/13/2020240267028Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/29/2020240267028Open ↗
01/13/2020240267028Open ↗
▸Filing & Intake Forms4
▸BISADDITIONAL INFORMATION3
10/29/2021240267028Open ↗
05/06/2020240267028Open ↗
04/29/2020240267028Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
01/13/2020240267028Open ↗