← Back
Two stories - detached, small or mid-size
133-03 SUTTER AVENUE
QUEENS · BIN 4255080
💬 Discuss this project
1920Year Built
2.5Stories
A1Building Class
R3-2Zoning
1,184 sfGross Floor Area
1Units
0 Open ViolationsFDNY Report ↗
Two stories - detached, small or mid-size · 1,988 sf lot · 0.6 FAR built · Flood zone X
Locations of Work
Mechanical
Floor 21 filing · 20 docs
Floor 11 filing · 20 docs
Cellar1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
06/07/2018$238K—NYC LEGACY PARTNERS LLC → Private party$201/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ARNOLD MONTAG ARCHITECT AM/PM DESI509/08/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AM PM DESIGN CONSULTING P C203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MP CONSTRUCTION D INCGeneral Contractor303/21/2026
HORBRIDGE PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
AFM INSPECTIONS & ENGINEE4675205/27/2022
ARNOLD MONTAG ARCHITECT,4599205/27/2022
Building Lifecycle
All (56)Filed (5)Permit Issued (2)Violation (3)Inspection (6)Objection (18)Special Inspection (22)
01/06/2023
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
09/08/2022
Filed — Alteration
Proposed plumbing work to existing one family two story with cellar residence.
Q00533887-P4
06/15/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/06/2022
Inspection — Fail-Final PL - Up to 3 Requested Floors
Fail
View inspection ↗
06/03/2022
Special inspection requirement — Interior lighting power
Arnold Montag
06/03/2022
Special inspection requirement — Ventilation and air distribution system
Arnold Montag
06/03/2022
Special inspection requirement — HVAC-R and service water heating system controls
Arnold Montag
06/03/2022
Special inspection requirement — Maintenance information
Arnold Montag
06/03/2022
Special inspection requirement — Fenestration areas
Arnold Montag
06/03/2022
Special inspection requirement — Mechanical Systems
Arnold Montag
06/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
Arnold Montag
06/03/2022
Special inspection requirement — Heating Systems
Anthony Marmo
06/03/2022
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
06/03/2022
Special inspection requirement — Fire-Resistance Rated Construction
Arnold Montag
06/03/2022
Special inspection requirement — Final
Arnold Montag
06/03/2022
Special inspection requirement — Fenestration air leakage
Arnold Montag
06/03/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
Arnold Montag
06/03/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
Arnold Montag
06/03/2022
Special inspection requirement — Air barrier - visual inspection
Arnold Montag
06/03/2022
Special inspection requirement — HVAC-R and service water heating equipment
Arnold Montag
06/03/2022
Special inspection requirement — Insulation placement and R values
Arnold Montag
06/03/2022
Special inspection requirement — Permanent certificate
Arnold Montag
05/31/2022
Objection resolved — Addressed
05/31/2022
Objection resolved — Addressed
05/30/2022
Objection raised — Accessibility
05/27/2022
Filed — Alteration
Proposed plumbing work to existing one family two story with cellar residence.
Q00533887-P1
05/25/2022
Objection raised — Energy
05/25/2022
Objection resolved — Addressed
05/25/2022
Objection raised — Other
05/25/2022
Objection raised — Other
05/25/2022
Objection resolved — Addressed
05/24/2022
Filed — Alteration
Proposed plumbing work to existing one family two story with cellar residence.
Q00533887-P3
03/16/2022
Special inspection requirement — Maintenance information
Arnold Montag
03/16/2022
Special inspection requirement — HVAC-R and service water heating system controls
Arnold Montag
03/16/2022
Special inspection requirement — HVAC-R and service water heating equipment
Arnold Montag
03/16/2022
Special inspection requirement — Energy Code Compliance Inspections
Arnold Montag
01/20/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/20/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
01/20/2022
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/28/2021
Permit issued — Plumbing
Q00533887-S1-PL
09/15/2021
Permit issued — Mechanical Systems
Q00533887-I1-GC-CX
08/11/2021
Filed — Alteration
Proposed plumbing work to existing one family two story with cellar residence.
Q00533887-S1
08/04/2021
Violation issued (ECB, closed)
Construction
07/08/2021
Objection raised — Other
07/08/2021
Objection resolved — Addressed
07/08/2021
Objection raised — Energy
07/08/2021
Objection resolved — Addressed
07/08/2021
Objection raised — Admin
07/08/2021
Objection resolved — Addressed
07/08/2021
Objection raised — Structural
07/08/2021
Objection resolved — Addressed
07/08/2021
Objection raised — Scope
07/08/2021
Objection resolved — Addressed
07/07/2021
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/23/2021
Filed — Alteration
Proposed plumbing work to existing one family two story with cellar residence.
Q00533887-I1
04/08/2021
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offHORBRIDGE PLUMBING & HEAT09/28/2021
DOB NOWMechanical SystemsPermit IssuedMP CONSTRUCTION D INC09/15/2021
1 project · most recent 09/08/2022
Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
09/08/2022Permit IssuedMP CONSTRUCTION D INCVentilation Systems
Ventilation
Greenheck Sp-B80 75 CFM · Exhaust Fan ×6
SP-A190 150 CFM · Kitchen Exhaust ×2
1 project · most recent 09/08/2022
Gas Water/Sanitary
FiledStatusContractorScope
09/08/2022Signed-offHORBRIDGE PLUMBING & HEATGas, Water/Sanitary
1 project · most recent 08/31/2021
General Wiring
FiledStatusContractorScope
08/31/2021CompleteTRINCITY ELECTRIC, INCGeneral Wiring
▾Field Inspections (DOB CAP) — 6
DateTypeResultReport
01/06/2023Fail-Final General Construction Non-Directive 14FailView ↗
06/15/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/06/2022Fail-Final PL - Up to 3 Requested FloorsFailView ↗
01/20/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/20/2022Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
01/20/2022Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 22
DateRequirementInspectorRole
06/03/2022Interior lighting powerArnold Montagenergy_progress
06/03/2022Ventilation and air distribution systemArnold Montagenergy_progress
06/03/2022HVAC-R and service water heating system controlsArnold Montagenergy_progress
06/03/2022Maintenance informationArnold Montagenergy_progress
06/03/2022Fenestration areasArnold Montagenergy_progress
06/03/2022Mechanical SystemsArnold Montagspecial
06/03/2022Fire-Resistant Penetrations and JointsArnold Montagspecial
06/03/2022Heating SystemsAnthony Marmospecial
06/03/2022Energy Code Compliance InspectionsArnold Montagprogress
06/03/2022Fire-Resistance Rated ConstructionArnold Montagprogress
06/03/2022FinalArnold Montagprogress
06/03/2022Fenestration air leakageArnold Montagenergy_progress
06/03/2022Fenestration and door U-factor and product ratingsArnold Montagenergy_progress
06/03/2022HVAC-R and service water piping design and insulationArnold Montagenergy_progress
06/03/2022Air barrier - visual inspectionArnold Montagenergy_progress
06/03/2022HVAC-R and service water heating equipmentArnold Montagenergy_progress
06/03/2022Insulation placement and R valuesArnold Montagenergy_progress
06/03/2022Permanent certificateArnold Montagenergy_progress
03/16/2022Maintenance informationArnold Montagenergy_progress
03/16/2022HVAC-R and service water heating system controlsArnold Montagenergy_progress
03/16/2022HVAC-R and service water heating equipmentArnold Montagenergy_progress
03/16/2022Energy Code Compliance InspectionsArnold Montagprogress
▾Documents — 31 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/25/2026Q00533887-S1Request digital key ↗
08/25/2026Q00533887-P3Request digital key ↗
08/25/2026Q00533887-P4Request digital key ↗
Showing 3 of 5 on file for this type
▸Seals & Professional Certifications21
▸DOB NOWProgress Inspector Seal & Signature13
09/02/2026Q00533887-I1Open ↗
09/02/2026Q00533887-I1Open ↗
09/02/2026Q00533887-I1Open ↗
Showing 3 of 13 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/25/2026Q00533887-S1Open ↗
08/25/2026Q00533887-I1Open ↗
08/25/2026Q00533887-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026Q00533887-I1Open ↗
09/02/2026Q00533887-I1Open ↗
09/02/2026Q00533887-I1Open ↗
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/25/2026Q00533887-S1Open ↗
08/25/2026Q00533887-P3Open ↗
08/25/2026Q00533887-P4Open ↗
Showing 3 of 5 on file for this type