← Back
Primarily 2 family with 1 store or office
133-19 41 ROAD
QUEENS · BIN 4114243
💬 Discuss this project
1950Year Built
2Stories
S2Building Class
R6Zoning
—Gross Floor Area
3Units
2 Open Violations ▸
Primarily 2 family with 1 store or office · 0.88 FAR built · Flood zone X
Locations of Work
Architecture
Floor 33p · 1 filing · 8 docs
Floor 2
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ALLEN SHINFELD, P.E. PLLC210/04/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
J R CONSULTING SERVICE403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
YOUN DESIGN CORPGeneral Contractor407/08/2026
XH&RC PLBG AND HTG INCPlumbing207/08/2026
LEVIS ELECTR'L CONTR. CORElectrical103/22/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ALLEN SHINFELD, P.E. PLLC1305210/04/2022
Building Lifecycle
All (19)Filed (2)Permit Issued (4)Signed Off (2)Violation (2)Inspection (2)Special Inspection (7)
05/27/2026
Signed off — Alteration
Interior Renovation of the 2nd Floor Dwelling Unit, Consisting of General Construction, Replacement of existing Plumbing Fixtures & Installation of New Plumbing Fixtures & Split Wall Units as per Plans. No change of Use, Occupancy or Egress
Q08008736-I1
05/27/2026
Signed off — Alteration
Replacement of Existing Plumbing Fixtures to existing water and sanitary roughing and installation of new Plumbing fixtures consisting of a 3-piece bathroom, Replacement of an Electrical Range at second floor dwelling unit
Q08014404-I1
05/12/2026
Violation issued (ECB, open)
Construction
05/12/2026
Violation issued (ECB, open)
Construction
11/05/2025
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
11/17/2023
Permit issued — Plumbing
Q08014404-I1-PL
04/22/2023
Permit issued — General Construction
Q08008736-I1-GC-CX
04/21/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/03/2022
Permit issued — Plumbing
Q08014404-I1-PL
11/01/2022
Permit issued — General Construction
Q08008736-I1-GC-CX
10/04/2022
Filed — Alteration
Interior Renovation of the 2nd Floor Dwelling Unit, Consisting of General Construction, Replacement of existing Plumbing Fixtures & Installation of New Plumbing Fixtures & Split Wall Units as per Plans. No change of Use, Occupancy or Egress
Q08008736-I1
10/04/2022
Filed — Alteration
Replacement of Existing Plumbing Fixtures to existing water and sanitary roughing and installation of new Plumbing fixtures consisting of a 3-piece bathroom, Replacement of an Electrical Range at second floor dwelling unit
Q08014404-I1
10/03/2022
Special inspection requirement — HVAC-R and service water heating equipment
ALLEN SHINFELD
10/03/2022
Special inspection requirement — Interior lighting power
ALLEN SHINFELD
10/03/2022
Special inspection requirement — HVAC-R and service water heating system controls
ALLEN SHINFELD
10/03/2022
Special inspection requirement — Maintenance information
ALLEN SHINFELD
10/03/2022
Special inspection requirement — HVAC-R and service water piping design and insulation
ALLEN SHINFELD
10/03/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALLEN SHINFELD
10/03/2022
Special inspection requirement — Energy Code Compliance Inspections
ALLEN SHINFELD
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC11/17/2023
DOB NOWGeneral ConstructionSigned-offYOUN DESIGN CORP04/22/2023
DOB NOWPlumbingSigned-offXH&RC PLBG AND HTG INC11/03/2022
DOB NOWGeneral ConstructionSigned-offYOUN DESIGN CORP11/01/2022
BISOTISSUEDSHINY CONSTRUCTION INC04/25/2000
1 project · most recent 10/04/2022
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/04/2022Signed-offYOUN DESIGN CORPHeating and Air Conditioning Systems
Heat / Cool
Mitsubishi Electric MXZ-2C20NAHZ3-U1 18,000 BTU · Heat Pump Outdoor ×1
MXZ-3C24NAHZ3-U1 22,000 BTU · Heat Pump Outdoor ×1
1 project · most recent 10/04/2022
Water/Sanitary
FiledStatusContractorScope
10/04/2022Signed-offXH&RC PLBG AND HTG INCWater/Sanitary
1 project · most recent 01/25/2023
General Wiring
FiledStatusContractorScope
01/25/2023Permit IssuedLEVIS ELECTR'L CONTR. CORGeneral Wiring
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
11/05/2025Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
04/21/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 7
DateRequirementInspectorRole
10/03/2022HVAC-R and service water heating equipmentALLEN SHINFELDenergy_progress
10/03/2022Interior lighting powerALLEN SHINFELDenergy_progress
10/03/2022HVAC-R and service water heating system controlsALLEN SHINFELDenergy_progress
10/03/2022Maintenance informationALLEN SHINFELDenergy_progress
10/03/2022HVAC-R and service water piping design and insulationALLEN SHINFELDenergy_progress
10/03/2022Fire-Resistant Penetrations and JointsALLEN SHINFELDspecial
10/03/2022Energy Code Compliance InspectionsALLEN SHINFELDprogress
▾Documents — 13 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/25/2026Q08014404-I1Request digital key ↗
08/25/2026Q08008736-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature6
08/31/2026Q08014404-I1Open ↗
08/22/2026Q08008736-I1Open ↗
08/22/2026Q08008736-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026Q08014404-I1Open ↗
08/13/2026Q08008736-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/31/2026Q08014404-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026Q08014404-I1Open ↗
08/13/2026Q08008736-I1Open ↗