← Back
Two family converted from one family
133-20 126 STREET
QUEENS · South Ozone Park · BIN 4256060
💬 Discuss this project
1920Year Built
2Stories
B3Building Class
R3-2Zoning
1,344 sfGross Floor Area
2Units
Rent Stabilized3 Open Violations ▸FDNY Report ↗
Two family converted from one family · 4,000 sf lot · 0.34 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
CARENAGEMACABANA303/22/2026
CARIB HOLDING LLC103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/26/2022$1.1M—CARIB HOLDINGS LLC → Private party$807/sf building
10/22/2020$600K—SHAH NY BUILDER INC → CARIB HOLDINGS LLC$446/sf building
08/27/2019$460K—Private party → SHAH NY BUILDER INC$342/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ASKON ARCHITECTS, P.C.410/15/2021
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
BVC CONSULTING INCGeneral Contractor603/21/2026
CARENAGEMACABANA LLCGeneral Contractor303/21/2026
ACTIVE PLBG & HTG CORPPlumbing107/08/2026
Building Lifecycle
All (75)Filed (4)Permit Issued (4)Signed Off (3)Violation (50)Inspection (3)Objection (2)Special Inspection (9)
11/25/2025
Violation issued (HPD, open)
I
12/05/2024
Violation issued (HPD, open)
I
11/29/2023
Violation issued (HPD, open)
I
09/26/2022
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/16/2022
Signed off — Alteration
FILING FOR PLUMBING WORK
Q00522146-I1
08/16/2022
Signed off — Alteration
Q00482751-I1
08/16/2022
Signed off — Alteration
FILING FOR CONSTRUCTION FENCE
Q00612567-I1
06/08/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/10/2022
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/17/2022
Violation issued (HPD, closed)
I
10/21/2021
Permit issued — Construction Fence
Q00612567-I1-FN
10/21/2021
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/15/2021
Filed — Alteration
FILING FOR CONSTRUCTION FENCE
Q00612567-I1
10/14/2021
Special inspection requirement — Final
HANSA PERSAUD
10/07/2021
Permit issued — Plumbing
Q00522146-I1-PL
09/28/2021
Violation issued (ECB, closed)
Construction
09/28/2021
Violation issued (ECB, closed)
Construction
09/28/2021
Violation issued (ECB, closed)
Unknown
09/28/2021
Violation issued (ECB, closed)
Unknown
09/21/2021
Objection resolved — Addressed
08/21/2021
Objection raised — Scope
08/20/2021
Filed — Alteration
FILING FOR PLUMBING WORK
Q00522146-P1
08/20/2021
Permit issued — General Construction
Q00482751-I1-GC
07/22/2021
Permit issued — General Construction
Q00482751-I1-GC
06/24/2021
Filed — Alteration
FILING FOR PLUMBING WORK
Q00522146-I1
04/22/2021
Violation issued (HPD, closed)
I
03/20/2021
Filed — Alteration
Q00482751-I1
03/20/2021
Special inspection requirement — Fenestration areas
Akeeb Shekoni
03/20/2021
Special inspection requirement — Air barrier - visual inspection
Akeeb Shekoni
03/20/2021
Special inspection requirement — Fenestration and door U-factor and product ratings
Akeeb Shekoni
03/20/2021
Special inspection requirement — Insulation placement and R values
Akeeb Shekoni
03/20/2021
Special inspection requirement — Interior lighting power
Akeeb Shekoni
03/20/2021
Special inspection requirement — Fenestration air leakage
Akeeb Shekoni
03/08/2021
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
Daniel Boss
03/08/2021
Special inspection requirement — Final
HANSA PERSAUD
11/08/2019
Violation issued (HPD, closed)
I
07/11/2019
Violation issued (ECB, closed)
Construction
11/01/2018
Violation issued (HPD, closed)
I
06/19/2017
Violation issued (HPD, closed)
B
06/19/2017
Violation issued (HPD, closed)
B
06/19/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
C
04/07/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
B
04/07/2017
Violation issued (HPD, closed)
C
04/07/2017
Violation issued (HPD, closed)
C
01/19/2017
Violation issued (HPD, closed)
B
01/19/2017
Violation issued (HPD, closed)
B
01/19/2017
Violation issued (HPD, closed)
C
01/19/2017
Violation issued (HPD, closed)
C
01/19/2017
Violation issued (HPD, closed)
C
01/19/2017
Violation issued (HPD, closed)
C
12/19/2016
Violation issued (HPD, closed)
I
12/16/2016
Violation issued (HPD, closed)
B
12/16/2016
Violation issued (HPD, closed)
C
12/16/2016
Violation issued (HPD, closed)
B
Latest 60 of 75 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FenceSigned-offBVC CONTRACTING LLC10/21/2021
DOB NOWPlumbingSigned-offACTIVE PLBG & HTG CORP10/07/2021
DOB NOWGeneral ConstructionSigned-offBVC CONTRACTING LLC08/20/2021
DOB NOWGeneral ConstructionSigned-offCARENAGEMACABANA LLC07/22/2021
BISOTISSUEDJRS CONSTRUCTION & EXPEDITING02/11/2013
BISPLISSUEDATTACK PLUMBING INC02/11/2013
1 project · most recent 01/18/2021
FiledStatusContractorScope
01/18/2021CompleteELECTRICAL SOLUTIONS LLC3 meters, 3 new_meters
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
09/26/2022Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
05/10/2022Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
10/21/2021Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
10/14/2021FinalHANSA PERSAUDprogress
03/20/2021Fenestration areasAkeeb Shekonienergy_progress
03/20/2021Air barrier - visual inspectionAkeeb Shekonienergy_progress
03/20/2021Fenestration and door U-factor and product ratingsAkeeb Shekonienergy_progress
03/20/2021Insulation placement and R valuesAkeeb Shekonienergy_progress
03/20/2021Interior lighting powerAkeeb Shekonienergy_progress
03/20/2021Fenestration air leakageAkeeb Shekonienergy_progress
03/08/2021Subsurface Investigations (Borings/Test Pits)Daniel Bossspecial
03/08/2021FinalHANSA PERSAUDprogress
▾Documents — 53 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/27/2026Q00482751-I1Request digital key ↗
08/27/2026Q00522146-P1Request digital key ↗
08/27/2026Q00522146-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION2
01/06/2014420807826Open ↗
02/13/2013420807826Open ↗
▸BISWORK PERMIT APPLICATION2
02/13/2013420807826Open ↗
02/13/2013420807826Open ↗
▸BISIntent to Revoke Approval/Permit1
02/28/2014420807826Open ↗
▸BISNon-Directive 14 Construction Sign Off Including Sign Applications1
04/23/2014420807826Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISRESTRICTION: RESTRICTIVE DECLARATION1
02/28/2014420807826Open ↗
▸DOB NOWRestrictive Declaration/Easement 11
08/27/2026Q00522146-P1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00482751-I1Open ↗
▸Seals & Professional Certifications13
▸DOB NOWProgress Inspector Seal & Signature4
08/31/2026Q00612567-I1Open ↗
08/28/2026Q00482751-I1Open ↗
08/28/2026Q00482751-I1Open ↗
Showing 3 of 4 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION3
04/23/2014420807826Open ↗
02/13/2013420807826Open ↗
02/13/2013420807826Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/27/2026Q00482751-I1Open ↗
08/27/2026Q00522146-P1Open ↗
08/13/2026Q00612567-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
02/13/2013420807826Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
02/13/2013420807826Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
08/28/2026Q00482751-I1Open ↗
▸Trade Schedules & Equipment8
▸BISSELF-CERT PLUMBING NOTICE6
04/29/2014420807826Open ↗
04/03/2014420807826Open ↗
04/03/2014420807826Open ↗
Showing 3 of 6 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
01/06/2014420807826Open ↗
▸BISSCHEDULE B - PLUMBING1
02/13/2013420807826Open ↗
▸Safety & Tenant Protection1
▸BISSTREET TREE CHECKLIST1
02/13/2013420807826Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/27/2026Q00482751-I1Open ↗
08/27/2026Q00522146-P1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
02/13/2013420807826Open ↗
02/13/2013420807826Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
04/23/2014420807826Open ↗
▸Inspections & Test Reports3
▸DOB NOWTR4 Test Report and Plot Diagram1
08/13/2026Q00482751-I1Open ↗
▸DOB NOWSOIL REPORT1
08/13/2026Q00482751-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/13/2026Q00482751-I1Open ↗
▸Approvals, Objections & Sign-offs4
▸BISLETTERS - SUPPORTING DOCUMENTATION2
04/29/2014420807826Open ↗
04/23/2014420807826Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
02/13/2013420807826Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
04/23/2014420807826Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
04/23/2014420807826Open ↗
02/13/2013420807826Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
01/06/2014420807826Open ↗
▸BISEFILING COVER SHEET1
02/13/2013420807826Open ↗
▸Other Documents2
▸DOB NOWPlot Diagram1
08/13/2026Q00482751-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00482751-I1Open ↗