← Back
Two family converted from one family
133-42 121 STREET
QUEENS · South Ozone Park · BIN 4254506
💬 Discuss this project
1925Year Built
2Stories
B3Building Class
R3-2Zoning
4,194 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,000 sf lot · 1.05 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingEquipmentCivilGeneral
Attic34p · 1 filing · 20 docs
Floor 234p · 1 filing · 20 docs
Floor 134p · 1 filing · 20 docs
Cellar42p · 1 filing · 20 docs
Site & exterior84p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/17/2022$820K—— → —$196/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CL ENGINEERING P.C.1108/01/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
METRO DESIGN CONSULTANTS INC2203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CROWN REMODELING INCGeneral Contractor307/08/2026
J&J DESIGNS INCGeneral Contractor303/21/2026
GAROFALO PLMBNG & HTG LTDPlumbing207/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CL ENGINEERING P.C.6781908/01/2023
TRIANGLE INSPECTION & TES7495308/01/2023
Building Lifecycle
All (32)Filed (11)Permit Issued (5)Signed Off (2)Violation (5)Inspection (9)
09/10/2025
Violation issued (ECB, closed)
Construction
09/10/2025
Violation issued (ECB, closed)
Zoning
09/15/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-S2
09/13/2023
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/01/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P9
08/01/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-A1
07/19/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
07/05/2023
Signed off — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-S1
04/12/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/27/2023
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
03/24/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/24/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
03/24/2023
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/21/2023
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
03/20/2023
Permit issued — Plumbing
Q00752643-S2-PL
03/03/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P8
03/01/2023
Permit issued — Plumbing
Q00752643-S2-PL
02/10/2023
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P6
01/19/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
11/11/2022
Permit issued — Earth Work
Q00752643-I1-GC-CX
10/27/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P4
10/20/2022
Violation issued (ECB, closed)
Construction
10/20/2022
Violation issued (ECB, closed)
Construction
10/20/2022
Violation issued (ECB, closed)
Construction
08/18/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P3
08/17/2022
Permit issued — Earth Work
Q00752643-I1-GC-CX
08/09/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P2
08/08/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-P1
08/01/2022
Permit issued — Construction Fence
Q00752643-S1-FN
07/27/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-S1
07/22/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-S2
07/06/2022
Filed — ALT-CO - New Building with Existing Elements to Remain
CONVERSION OF THE EXISTING TWO STORY ONE FAMILY BUILDING INTO A TWO STORY TWO FAMILY BUILDING AS SHOWN ON THE PLANS. PROPOSED HORIZONTAL ENLARGEMENT. INTERIOR RENOVATION AS PER PLAN. OBTAIN A NEW CERTIFICATE OF OCCUPANCY.
Q00752643-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offGAROFALO PLMBNG & HTG LTD03/20/2023
DOB NOWPlumbingSigned-offGAROFALO PLMBNG & HTG LTD03/01/2023
DOB NOWEarth WorkPermit IssuedJ&J DESIGNS INC11/11/2022
DOB NOWEarth WorkPermit IssuedCROWN REMODELING08/17/2022
DOB NOWConstruction FenceSigned-offCROWN REMODELING08/01/2022
1 project · most recent 08/01/2023
Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
08/01/2023Permit IssuedJ&J DESIGNS INCAir Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Fujitsu F06013CSJNAA 60,000 BTU · Condensing Unit ×4
Heating
Fujitsu FF115245TS92 M 112,000 BTU · Furnace ×2
FF75174CS80M 75,000 BTU · Furnace ×2
Ventilation
Hampton Bay 7114-01 50 CFM · Exhaust Fan ×10
Delta Breeze SMT150 150 CFM · Exhaust Fan ×4
1 project · most recent 08/01/2023
Gas Storm Water/Sanitary
FiledStatusContractorScope
08/01/2023Signed-offGAROFALO PLMBNG & HTG LTDGas, Storm, Water/Sanitary
3 projects · most recent 08/17/2023
General Wiring
FiledStatusContractorScope
08/17/2023CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
05/01/2023CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
08/18/2022CompletePOWER SURGE ELECTRIC, INCGeneral Wiring
1 project · most recent 08/01/2023
Steel Wood
FiledStatusContractorScope
08/01/2023Signed-offGAROFALO PLMBNG & HTG LTDSteel, Wood
1 project · most recent 08/01/2023
Fence
FiledStatusContractorScope
08/01/2023Signed-offGAROFALO PLMBNG & HTG LTDFence
▾Field Inspections (DOB CAP) — 9
DateTypeResultReport
09/13/2023Pass-Final CND-Occupancy InspectionPassView ↗
07/19/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/12/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/27/2023Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
03/24/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/24/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
03/24/2023Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/21/2023Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
01/19/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 150
DateRequirementInspectorRole
09/05/2023Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationCHRISTIAN LOZADAspecial
09/05/2023Structural Steel - DetailsCHRISTIAN LOZADAspecial
09/05/2023Subsurface Investigations (Borings/Test Pits)Rajasekhar Sakhamurispecial
09/05/2023Excavations - Sheeting, Shoring, and BracingCHRISTIAN LOZADAspecial
09/05/2023Heating SystemsCHRISTIAN LOZADAspecial
09/05/2023Structural Steel - High Strength BoltingCHRISTIAN LOZADAspecial
09/05/2023MasonryCHRISTIAN LOZADAspecial
09/05/2023Subgrade InspectionsCHRISTIAN LOZADAspecial
09/05/2023Mechanical SystemsCHRISTIAN LOZADAspecial
09/05/2023Fire-Resistant Penetrations and JointsCHRISTIAN LOZADAspecial
09/05/2023Concrete - Cast-In-PlaceCHRISTIAN LOZADAspecial
09/05/2023Structural Stability – Alterations of existing buildingsCHRISTIAN LOZADAspecial
09/05/2023Fire-Resistance Rated ConstructionCHRISTIAN LOZADAprogress
09/05/2023Energy Code Compliance InspectionsCHRISTIAN LOZADAprogress
09/05/2023FinalCHRISTIAN LOZADAprogress
09/05/2023Footing and FoundationCHRISTIAN LOZADAprogress
09/05/2023Structural Wood FrameCHRISTIAN LOZADAprogress
09/05/2023HVAC-R and service water heating equipmentCHRISTIAN LOZADAenergy_progress
09/05/2023Air barrier - visual inspectionCHRISTIAN LOZADAenergy_progress
09/05/2023Fenestration and door U-factor and product ratingsCHRISTIAN LOZADAenergy_progress
09/05/2023HVAC-R and service water heating system controlsCHRISTIAN LOZADAenergy_progress
09/05/2023MeteringCHRISTIAN LOZADAenergy_progress
09/05/2023Ventilation and air distribution systemCHRISTIAN LOZADAenergy_progress
09/05/2023Duct leakage testing, insulation and designCHRISTIAN LOZADAenergy_progress
09/05/2023Maintenance informationCHRISTIAN LOZADAenergy_progress
Latest 25 of 150.
▾Documents — 163 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/26/2026Q00752643-P4Request digital key ↗
08/26/2026Q00752643-P6Request digital key ↗
08/26/2026Q00752643-P8Request digital key ↗
Showing 3 of 11 on file for this type
▸Zoning, Tax Lot & Property Records7
▸DOB NOWZD1: DOB Zoning Diagram6
08/26/2026Q00752643-P6Open ↗
08/14/2026Q00752643-I1Open ↗
08/13/2026Q00752643-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026Q00752643-I1Open ↗
▸Seals & Professional Certifications105
▸DOB NOWProgress Inspector Seal & Signature69
09/01/2026Q00752643-P8Open ↗
09/01/2026Q00752643-P8Open ↗
08/28/2026Q00752643-S2Open ↗
Showing 3 of 69 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature25
09/01/2026Q00752643-P8Open ↗
09/01/2026Q00752643-P8Open ↗
08/28/2026Q00752643-S2Open ↗
Showing 3 of 25 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/26/2026Q00752643-P6Open ↗
08/26/2026Q00752643-P8Open ↗
08/26/2026Q00752643-P9Open ↗
Showing 3 of 11 on file for this type
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report10
08/26/2026Q00752643-P6Open ↗
08/26/2026Q00752643-P8Open ↗
08/26/2026Q00752643-P9Open ↗
Showing 3 of 10 on file for this type
▸Energy Compliance1
▸DOB NOWEN2: As Built Energy Analysis1
08/14/2026Q00752643-I1Open ↗
▸Inspections & Test Reports8
▸DOB NOWSOIL REPORT6
08/26/2026Q00752643-P6Open ↗
08/14/2026Q00752643-I1Open ↗
08/13/2026Q00752643-P4Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWTR4 Test Report and Plot Diagram1
08/14/2026Q00752643-I1Open ↗
▸DOB NOWTR4 Plot Diagram1
08/14/2026Q00752643-I1Open ↗
▸Other Documents21
▸DOB NOWProperty Ownership Certification7
08/26/2026Q00752643-P4Open ↗
08/26/2026Q00752643-P2Open ↗
08/26/2026Q00752643-P6Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWSite Survey: Initial6
08/26/2026Q00752643-P6Open ↗
08/14/2026Q00752643-I1Open ↗
08/13/2026Q00752643-P3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone6
08/26/2026Q00752643-P6Open ↗
08/14/2026Q00752643-I1Open ↗
08/13/2026Q00752643-P3Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWFinal Survey1
08/14/2026Q00752643-I1Open ↗
▸DOB NOWAdjoining Owners Notification1
08/14/2026Q00752643-I1Open ↗