ECB12/06/2025FAILURE TO COMPLY WITH A LAW, RULE, OR COMMISSIONER'S ORDER INVOLVING CONSTRUCTION SAFETY OPERATIONS. AT TIME OF REINSPECTION, OWNER FAILED TO COMPLY WITH EMERGENCY ORDER ISSUED UNDER VIOLATION #25-02922, WHICH$25K due
ECB12/06/2025WORK WITHOUT PERMIT. AT REAR OF PREMISES I OBSERVED WORKED PERFORMING UNKNOWN FACADE WORK WAS BEING DONE REPAIRING A GAPING HOLE AND CRACKS AT REAR OF BUILDING. THERE ARE NO PERMITS ON FILE FOR THIS WORK., OBTA$12K due
ECB12/06/2025FAILURE TO COMPLY WITH COMMISSIONERS ORDERS. AT TIME OF REINSPECTION THE VACATE THAT WAS ISSUED ON 11/29/25 WAS NO T BEING FOLLOWED WITH OCCUPANCY OBSERVED AT APTS #1 AND #2 WHILE ILLEGAL CONSTRUCTION WORK WAS$12K due
DOB12/04/2025EMERGENCY WORK ORDER.EXP4 LOAD BEARNG WALL APPRX 20LINEAR FT WAS BULGNG OUT ALNG 2NDFL LVL@EXISTNG CHIMNEY FLUTE&EXTENDED ON EACH SIDE PER 20FT LENGTH ALNG EXPOSD WALL VERT CRCKS@CHIMNEY FLUTE BTWN IMMEDIATELY COMPLY COMMISSIONER'S ORDER 350229 (110125FEU30201PN)DATED 12/1/2025
ECB12/01/2025FAILURE TO MAINTAIN THE BUILDING IN A CODE-COMPLIANT MANNER: THE EXPOSURE 4 FACADE IS IN A STATE OF DISREPAIR. THERE IS AN EXPOSED HOLE IN THE WALL, MULTIPLE BRICKS HAVE BEEN REMOVED, AND THE WALL IS LEANING OU$2K due
DOB12/01/2025REQUESTING AN ENGINEERING REPORT DUE TO A SECTION OF THE FA ADE AT EXPOSURE 4 THAT COULD POTENTIALLY COLLAPSE ONTO THE ADJACENT PROPERTY. AN ENGINEERING ASSESSMENT IS REQUIRED TO EVALUATE THE CONDITION AND DETERMINE THE NECESSARY REPAIRS TO ADDRESS THE DAMAGE SUSTAINED.
DOB12/01/2025EMERGENCY WORK ORDER.EXP4 LOAD BEARNG WALL APPRX 20LINEAR FT WAS BULNG OUT ALNG 2NDFLL LVL@EXISTNG CHINEY FLUTE&EXTNDED ON EACH SIDE PER 20FT LENGTH ALNG EXPOSD WALL VERT CRCKS@CHIMNEY FLUTE BTWN IMMEDIATELY COMPLY COMMISSIONER ORDER 350229 (110125FEU30201PN) DATED 12/1/2025
DOB12/01/2025FAILURE TO MAINTAIN.EXP4 LOAD BEARNG WALL APPRX 20LINEAR FEET WAS BULGD OUT ALNG 2NDFL LVL@EXISTNG CHIMNEY FLUTE&EXTENDED ON EACH SIDE PER 20FT LENGTH ALNG EXPOSD WALL.VERT CRCKS@CHIMNEY FLUTE.OWNR TO RTAIN NYSPE TO EVAL ENT BLDG & FIE DWGS W/DOB.PERM RPAIR BLDG UNDR STRTNG BY 2/9/26&CMPLTD/SGN OFF BY 3/31/26
HPD08/06/2019§ 27-2005, 27-2007, 27-2041.1 HMC: REPLACE OR REPAIR THE SELF-CLOSING DOORS THAT IS MISSING OR DEFECTIVE .. IN THE ENTRANCE LOCATED AT APT 5, 3rd STORY, 1st APARTMENT FROM WEST AT NORTH
HPD01/10/2019§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR CEILING IN THE BATHROOM LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM WEST AT NORTH
HPD08/30/2018§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM WINDOW TO FIRE ESCAPE OR PROVIDE APPROVED TYPE GATE .. IN THE 4th ROOM FROM NORTH LOCATED AT APT 10, 4th STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD08/28/2018§ 27-2005 ADM CODE & 309 M/D LAW ABATE THE NUISANCE CONSISTING OF MORTISE LOCK ON DOOR TO ROOM WITH FIRE ESCAPE WINDOW IN THE 5th ROOM FROM NORTH LOCATED AT APT 4, 2nd STORY, 2nd APARTMENT FROM EAST AT SOUTH
HPD06/06/2017§ 27-2005, 2007 ADM CODE FIRE EGRESS DEFECTIVE. REMOVE OBSTRUCTING BARS OR UNLAWFUL GATES FROM AT LEAST 1 WINDOW OR PROVIDE APPROVED TYPE GATE .. IN THE ENTIRE APARTMENT LOCATED AT APT 1, 1st STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD08/16/1990§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CEMENT PLASTER CEILING CELLAR THRU OUT