← Back
Two family brick
133 WEST 69 STREET
MANHATTAN · Upper West Side-Lincoln Square · BIN 1029637
💬 Discuss this project
1892Year Built
4Stories
B1Building Class
R8BZoning
5,615 sfGross Floor Area
2Units
0 Open Violations
Two family brick · 1,908 sf lot · 2.94 FAR built · Flood zone X
Locations of Work
No floor-level scope or drawing coverage on file for this building.
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NICOLE MIGEON ARCHITECT, PLLC410/04/2021
BAILEYS ENGINEERING PC210/15/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
GANCI LOGOZZO803/21/2026
AE DESIGN SOLUTION403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TBRO'S RENOVATION INCGeneral Contractor607/08/2026
EVEREST SCAFFOLDING INCGeneral Contractor403/21/2026
GREGORY PAPANTONIOUElectrical103/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CROSSCHECK INSPECTION SER544210/01/2021
Building Lifecycle
All (32)Filed (6)Permit Issued (6)Signed Off (4)Violation (2)Objection (2)Special Inspection (12)
12/13/2021
Signed off — Alteration
Structural filing for replacement of steel stair at rear, no change to use , occupancy or egress.
M00503604-S1
12/08/2021
Signed off — Alteration
Structural filing for replacement of steel stair at rear, no change to use , occupancy or egress.
M00503604-I1
10/04/2021
Filed — Alteration
Structural filing for replacement of steel stair at rear, no change to use , occupancy or egress.
M00503604-P1
10/04/2021
Special inspection requirement — Concrete - Cast-In-Place
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Subgrade Inspections
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Structural Steel - Welding
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Structural Steel - High Strength Bolting
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Structural Steel - Details
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Subsurface Conditions – Fill Placement & In-Place Density
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Post-installed Anchors
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Structural Stability – Alterations of existing buildings
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Final
EUGENE BIFULCO
10/04/2021
Special inspection requirement — Final
Nicole Migeon
10/01/2021
Filed — Alteration
Structural filing for replacement of steel stair at rear, no change to use , occupancy or egress.
M00503604-P2
09/30/2021
Special inspection requirement — Final
Nicole Migeon
09/28/2021
Permit issued — Structural
M00503604-S1-ST
09/28/2021
Permit issued — General Construction
M00503604-I1-GC
07/08/2021
Permit issued — General Construction
M00503604-I1-GC
07/08/2021
Permit issued — Structural
M00503604-S1-ST
06/07/2021
Filed — Alteration
Structural filing for replacement of steel stair at rear, no change to use , occupancy or egress.
M00503604-S1
05/04/2021
Objection raised — Scope
05/04/2021
Objection resolved — Addressed
05/03/2021
Filed — Alteration
Structural filing for replacement of steel stair at rear, no change to use , occupancy or egress.
M00503604-I1
07/25/2019
Signed off — Alteration
M00086483-I1
07/25/2019
Signed off — Alteration
M00086482-I1
10/15/2018
Filed — Alteration
M00086483-I1
10/15/2018
Permit issued — Sidewalk Shed
M00086482-I1-SH
10/15/2018
Permit issued — Supported Scaffold
M00086483-I1-SF
10/12/2018
Filed — Alteration
M00086482-I1
10/09/2018
Special inspection requirement — Final
PAUL BAILEY
02/13/2004
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/19/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWStructuralSigned-offTBRO'S RENOVATION INC09/28/2021
DOB NOWGeneral ConstructionSigned-offTBRO'S RENOVATION INC09/28/2021
DOB NOWGeneral ConstructionSigned-offTBRO'S RENOVATION INC07/08/2021
DOB NOWStructuralSigned-offTBRO'S RENOVATION INC07/08/2021
DOB NOWSidewalk ShedSigned-offEVEREST SCAFFOLDING INC10/15/2018
DOB NOWSupported ScaffoldSigned-offEVEREST SCAFFOLDING INC10/15/2018
BIS—ISSUEDTRIESTE CONSTRUCTION CORP05/09/2001
BISOTISSUEDTRIESTE CONSTRUCTION CORP04/18/2001
BISPLISSUEDSEVIEW PLUMBING INC.03/06/2001
BISBLISSUEDEAST COAST MECHANICAL LLC03/01/2001
BISOTISSUEDTRIESTE CONSTRUCTION CORP02/28/2001
1 project · most recent 10/12/2018
FiledStatusContractorScope
10/12/2018CompleteBOROWIDE ELECT'L CONTR'S—
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
10/04/2021Concrete - Cast-In-PlaceEUGENE BIFULCOspecial
10/04/2021Subgrade InspectionsEUGENE BIFULCOspecial
10/04/2021Structural Steel - WeldingEUGENE BIFULCOspecial
10/04/2021Structural Steel - High Strength BoltingEUGENE BIFULCOspecial
10/04/2021Structural Steel - DetailsEUGENE BIFULCOspecial
10/04/2021Subsurface Conditions – Fill Placement & In-Place DensityEUGENE BIFULCOspecial
10/04/2021Post-installed AnchorsEUGENE BIFULCOspecial
10/04/2021Structural Stability – Alterations of existing buildingsEUGENE BIFULCOspecial
10/04/2021FinalEUGENE BIFULCOprogress
10/04/2021FinalNicole Migeonprogress
09/30/2021FinalNicole Migeonprogress
10/09/2018FinalPAUL BAILEYprogress
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings6
▸DOB NOWPlans/Sketch6
09/06/2026M00086482-I1Request digital key ↗
09/06/2026M00086483-I1Request digital key ↗
09/03/2026M00503604-S1Request digital key ↗
Showing 3 of 6 on file for this type
▸Applications & Permits4
▸DOB NOWLPC Approval/Permit4
08/13/2026M00503604-P2Open ↗
08/13/2026M00503604-P1Open ↗
08/13/2026M00503604-I1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications18
▸DOB NOWSpecial Inspector Seal & Signature8
09/01/2026M00503604-S1Open ↗
09/01/2026M00503604-S1Open ↗
09/01/2026M00503604-S1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature6
08/13/2026M00503604-P1Open ↗
08/13/2026M00503604-I1Open ↗
08/13/2026M00503604-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026M00503604-I1Open ↗
09/01/2026M00503604-S1Open ↗
08/27/2026M00086482-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos5
▸DOB NOWDEP ACP-5: Asbestos Assessment Report5
08/13/2026M00503604-P2Open ↗
08/13/2026M00503604-P1Open ↗
08/13/2026M00086483-I1Open ↗
Showing 3 of 5 on file for this type