← Back
Two family brick
1330 EAST 36 STREET
BROOKLYN · Flatlands · BIN 3210583
💬 Discuss this project
1925Year Built
2Stories
B1Building Class
R4Zoning
2,480 sfGross Floor Area
2Units
Two family brick · 2,492 sf lot · 1 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbing
Floor 221p · 1 filing · 20 docs
Floor 118p · 1 filing · 20 docs
Cellar17p · 1 filing · 20 docs
Site & exterior6p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/03/2025$1.1M—— → —$464/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LU ENGINEERING SERVICE PC403/18/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
H Z BUILDING NY603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
MEGA GENERAL CONSTR NYCGeneral Contractor104/09/2026
MEGA GENERAL CONSTRUCTIONGeneral Contractor104/09/2026
TRI STATE PLBG & HTG INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
LU ENGINEERING SERVICE PC6575403/18/2026
Building Lifecycle
All (53)Filed (4)Permit Issued (3)Signed Off (2)Inspection (10)Objection (4)Special Inspection (30)
07/14/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/18/2026
Signed off — Alteration
PROPOSED INTERIOR RENOVATION WORK WITH REPAIRING PARTITION, FLOORING, CEILING ON CEL, 1ST AND 2ND FLOOR. MS WORK FOR INSTALL SPLIT AC UNITS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01257231-I1
05/13/2026
Signed off — Alteration
PROPOSED INTERIOR RENOVATION WORK WITH REPAIRING PARTITION, FLOORING, CEILING ON CEL, 1ST AND 2ND FLOOR. MS WORK FOR INSTALL SPLIT AC UNITS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01257231-S1
05/06/2026
Inspection — Fail-Final General Construction Non-Directive 14
Fail
View inspection ↗
04/01/2026
Special inspection requirement — Mechanical Systems
DONGSHENG LU
04/01/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DONGSHENG LU
04/01/2026
Special inspection requirement — Final
Fran Huang
04/01/2026
Special inspection requirement — Energy Code Compliance Inspections
DONGSHENG LU
04/01/2026
Special inspection requirement — Fire-Resistance Rated Construction
DONGSHENG LU
04/01/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
DONGSHENG LU
04/01/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
DONGSHENG LU
04/01/2026
Special inspection requirement — Air barrier - visual inspection
DONGSHENG LU
04/01/2026
Special inspection requirement — Fenestration air leakage
DONGSHENG LU
04/01/2026
Special inspection requirement — HVAC-R and service water heating system controls
DONGSHENG LU
04/01/2026
Special inspection requirement — Fenestration areas
DONGSHENG LU
04/01/2026
Special inspection requirement — Interior lighting power
DONGSHENG LU
04/01/2026
Special inspection requirement — HVAC-R and service water heating equipment
DONGSHENG LU
04/01/2026
Special inspection requirement — Insulation placement and R values
DONGSHENG LU
03/27/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/18/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION WORK WITH REPAIRING PARTITION, FLOORING, CEILING ON CEL, 1ST AND 2ND FLOOR. MS WORK FOR INSTALL SPLIT AC UNITS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01257231-P2
03/18/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
03/16/2026
Special inspection requirement — Insulation placement and R values
DONGSHENG LU
03/16/2026
Special inspection requirement — Final
Fran Huang
03/16/2026
Special inspection requirement — Fire-Resistance Rated Construction
DONGSHENG LU
03/16/2026
Special inspection requirement — HVAC-R and service water heating equipment
DONGSHENG LU
03/16/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
DONGSHENG LU
03/16/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
DONGSHENG LU
03/16/2026
Special inspection requirement — Air barrier - visual inspection
DONGSHENG LU
03/16/2026
Special inspection requirement — HVAC-R and service water heating system controls
DONGSHENG LU
03/16/2026
Special inspection requirement — Fenestration areas
DONGSHENG LU
03/16/2026
Special inspection requirement — Interior lighting power
DONGSHENG LU
03/16/2026
Special inspection requirement — Fenestration air leakage
DONGSHENG LU
03/16/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
DONGSHENG LU
03/16/2026
Special inspection requirement — Mechanical Systems
DONGSHENG LU
03/16/2026
Special inspection requirement — Energy Code Compliance Inspections
DONGSHENG LU
02/20/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
02/03/2026
Special inspection requirement — Energy Code Compliance Inspections
DONGSHENG LU
02/03/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
DONGSHENG LU
01/22/2026
Filed — Alteration
PROPOSED INTERIOR RENOVATION WORK WITH REPAIRING PARTITION, FLOORING, CEILING ON CEL, 1ST AND 2ND FLOOR. MS WORK FOR INSTALL SPLIT AC UNITS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01257231-P1
01/20/2026
Permit issued — General Construction
B01257231-I1-GC-CX
01/15/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
11/14/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/18/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
08/20/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
08/18/2025
Permit issued — Mechanical Systems
B01257231-I1-GC-CX
08/15/2025
Permit issued — Plumbing
B01257231-S1-PL
08/05/2025
Objection resolved — Addressed
08/05/2025
Objection resolved — Addressed
08/04/2025
Objection raised — Cost
08/04/2025
Objection raised — Cost
07/24/2025
Filed — Alteration
PROPOSED INTERIOR RENOVATION WORK WITH REPAIRING PARTITION, FLOORING, CEILING ON CEL, 1ST AND 2ND FLOOR. MS WORK FOR INSTALL SPLIT AC UNITS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01257231-I1
07/24/2025
Filed — Alteration
PROPOSED INTERIOR RENOVATION WORK WITH REPAIRING PARTITION, FLOORING, CEILING ON CEL, 1ST AND 2ND FLOOR. MS WORK FOR INSTALL SPLIT AC UNITS. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B01257231-S1
08/30/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionSigned-offMEGA GENERAL CONSTR NYC01/20/2026
DOB NOWMechanical SystemsSigned-offMEGA GENERAL CONSTRUCTION08/18/2025
DOB NOWPlumbingSigned-offDW PLUMBING INC08/15/2025
1 project · most recent 03/18/2026
Gas Water/Sanitary
FiledStatusContractorScope
03/18/2026Signed-offDW PLUMBING INCGas, Water/Sanitary
1 project · most recent 07/15/2025
General Wiring
FiledStatusContractorScope
07/15/2025CompleteJ Y ELECTRIC INCGeneral Wiring
▾Field Inspections (DOB CAP) — 10
DateTypeResultReport
07/14/2026Pass-Final CND-Occupancy InspectionPassView ↗
05/06/2026Fail-Final General Construction Non-Directive 14FailView ↗
03/27/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/18/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
02/20/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/15/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
11/14/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/18/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
08/20/2025Pass-Final CND-Occupancy InspectionPassView ↗
08/30/2024Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
04/01/2026Mechanical SystemsDONGSHENG LUspecial
04/01/2026Fire-Resistant Penetrations and JointsDONGSHENG LUspecial
04/01/2026FinalFran Huangprogress
04/01/2026Energy Code Compliance InspectionsDONGSHENG LUprogress
04/01/2026Fire-Resistance Rated ConstructionDONGSHENG LUprogress
04/01/2026Fenestration and door U-factor and product ratingsDONGSHENG LUenergy_progress
04/01/2026HVAC-R and service water piping design and insulationDONGSHENG LUenergy_progress
04/01/2026Air barrier - visual inspectionDONGSHENG LUenergy_progress
04/01/2026Fenestration air leakageDONGSHENG LUenergy_progress
04/01/2026HVAC-R and service water heating system controlsDONGSHENG LUenergy_progress
04/01/2026Fenestration areasDONGSHENG LUenergy_progress
04/01/2026Interior lighting powerDONGSHENG LUenergy_progress
04/01/2026HVAC-R and service water heating equipmentDONGSHENG LUenergy_progress
04/01/2026Insulation placement and R valuesDONGSHENG LUenergy_progress
03/16/2026Insulation placement and R valuesDONGSHENG LUenergy_progress
03/16/2026FinalFran Huangprogress
03/16/2026Fire-Resistance Rated ConstructionDONGSHENG LUprogress
03/16/2026HVAC-R and service water heating equipmentDONGSHENG LUenergy_progress
03/16/2026HVAC-R and service water piping design and insulationDONGSHENG LUenergy_progress
03/16/2026Fenestration and door U-factor and product ratingsDONGSHENG LUenergy_progress
03/16/2026Air barrier - visual inspectionDONGSHENG LUenergy_progress
03/16/2026HVAC-R and service water heating system controlsDONGSHENG LUenergy_progress
03/16/2026Fenestration areasDONGSHENG LUenergy_progress
03/16/2026Interior lighting powerDONGSHENG LUenergy_progress
03/16/2026Fenestration air leakageDONGSHENG LUenergy_progress
Latest 25 of 38.
▾Documents — 54 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/17/2026B01257231-P1Request digital key ↗
08/17/2026B01257231-S1Request digital key ↗
08/17/2026B01257231-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Zoning, Tax Lot & Property Records4
▸DOB NOWRestrictive Declaration/Easement 14
08/17/2026B01257231-S1Open ↗
08/17/2026B01257231-I1Open ↗
08/13/2026B01257231-P1Open ↗
Showing 3 of 4 on file for this type
▸Seals & Professional Certifications42
▸DOB NOWProgress Inspector Seal & Signature32
09/23/2026B01257231-I1Open ↗
09/23/2026B01257231-I1Open ↗
09/23/2026B01257231-I1Open ↗
Showing 3 of 32 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/23/2026B01257231-I1Open ↗
09/23/2026B01257231-I1Open ↗
08/27/2026B01257231-S1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/17/2026B01257231-S1Open ↗
08/17/2026B01257231-I1Open ↗
08/13/2026B01257231-P2Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/17/2026B01257231-I1Open ↗
08/17/2026B01257231-S1Open ↗
08/13/2026B01257231-P2Open ↗
Showing 3 of 4 on file for this type