← Back
Two stories - detached, small or mid-size
1335 EAST 102 STREET
BROOKLYN · Canarsie · BIN 3233948
💬 Discuss this project
1960Year Built
1Stories
A1Building Class
R3XZoning
1,221 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 4,167 sf lot · 0.29 FAR built · Flood zone X500
Locations of Work
ArchitectureStructuralGeneralOther
Filed — no permit issued15p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/05/2018$600K—Private party → Private party$491/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ANTHONY HATZIIOANNOU ARCHITECT PC110/06/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
SUMMIT CONSULTING & EXPEDITING203/21/2026
Building Lifecycle
All (14)Filed (1)Special Inspection (13)
10/06/2022
Filed — Alteration CO
B07994847-I1
08/31/2022
Special inspection requirement — Interior lighting power
08/31/2022
Special inspection requirement — Insulation placement and R values
08/31/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
08/31/2022
Special inspection requirement — Masonry
08/31/2022
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
08/31/2022
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
08/31/2022
Special inspection requirement — Concrete - Cast-In-Place
08/31/2022
Special inspection requirement — Energy Code Compliance Inspections
08/31/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
08/31/2022
Special inspection requirement — Fenestration air leakage
08/31/2022
Special inspection requirement — Fenestration areas
08/29/2022
Special inspection requirement — Lowest Floor Elevation
08/29/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
Nothing on file for this building.
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
08/31/2022Interior lighting power—energy_progress
08/31/2022Insulation placement and R values—energy_progress
08/31/2022Fire-Resistant Penetrations and Joints—special
08/31/2022Masonry—special
08/31/2022Subsurface Investigations (Borings/Test Pits)—special
08/31/2022Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
08/31/2022Concrete - Cast-In-Place—special
08/31/2022Energy Code Compliance Inspections—progress
08/31/2022Fenestration and door U-factor and product ratings—energy_progress
08/31/2022Fenestration air leakage—energy_progress
08/31/2022Fenestration areas—energy_progress
08/29/2022Lowest Floor Elevation—progress
08/29/2022Structural Stability – Alterations of existing buildings—special
▾Documents — 10 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/28/2026B07994847-I1Request digital key ↗
▸Zoning, Tax Lot & Property Records1
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026B07994847-I1Open ↗
▸Seals & Professional Certifications1
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/13/2026B07994847-I1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026B07994847-I1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/13/2026B07994847-I1Open ↗
▸Inspections & Test Reports1
▸DOB NOWSOIL REPORT1
08/13/2026B07994847-I1Open ↗
▸Other Documents4
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026B07994847-I1Open ↗
▸DOB NOWPlot Diagram1
08/13/2026B07994847-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/13/2026B07994847-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/13/2026B07994847-I1Open ↗