HPD03/17/2025§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AND CLEANABLE, POSITIVE LEAD-BASED PAINT IN AN APARTMENT WITH A CHILD UNDER SIX LOCATED AT APT 6H, 6th STORY, 1st APARTMENT FROM NORTH AT EAST
HPD04/11/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM NORTH AT EAST WALL DOOR IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/11/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st CLOSET FROM SOUTH AT WEST WALL DOOR IN THE PRIVATE HALLWAY LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/11/2024§ 27-2056.7, 27-2056.8, 27-2056.9 ADM CODE -CERTIFY COMPLIANCE WITH LEAD-BASED PAINT HAZARD CONTROL REQUIREMENTS DURING PERIOD OF UNIT VACANCY BY PERFORMING ACTIVITIES NECESSARY TO ABATE TESTED LEAD-BASED PAINT FROM REQUIRED WINDOW AND/OR DOOR FRICTION SURFACES FOR APARTMENT AND MAKE FLOORS SMOOTH AND CLEANABLE, POSITIVE LEAD-BASED PAINT IN AN APARTMENT WITH A CHILD UNDER SIX LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/11/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD-PAINT THAT IS XRF TESTED INCONCLUSIVE FOR LEAD CONTENT AT 0.5MG/CM2 AND IS PRESUMED LEAD PAINT AS SET FORTH IN (28 RCNY §11-07(b)) AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE-USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(b)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE FOYER LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
HPD04/11/2024§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FRAME FROM WEST AT NORTH WALL IN THE BATHROOM LOCATED AT APT 3F, 3rd STORY, 1st APARTMENT FROM EAST AT SOUTH
DOB04/29/2021FAILURE TO DISPLAY ENERGY EFFICIENCY SCORE AND ENERGY EFFICIENCY GRADE AS PER ADCODE SEC. 28-309.12.3
DOB11/08/2019VIOLATION ISSUED FOR FAILURE TO FILE ANNUAL BOILER 2017 INSPECTION REPORT
DOB08/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2019FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
HPD09/17/2018§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PAINT THAT TESTED POSITIVE FOR LEAD CONTENT AND THAT IS PEELING OR ON A DETERIORATED SUBSURFACE - USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) 1st DOOR FROM SOUTH AT WEST WALL IN THE FOYER LOCATED AT APT 4H, 4th STORY, 1st APARTMENT FROM NORTH AT EAST , SECTION AT EAST
HPD02/26/2009§ 27-2056.6 ADM CODE - CORRECT THE LEAD-BASED PAINT HAZARD - PRESUMED LEAD PAINT THAT IS PEELING OR ON A DETERIORATED SUBSURFACE USING WORK PRACTICES SET FORTH IN 28 RCNY §11-06(B)(2) CEILING, 1st DOOR FRAME FROM EAST AT SOUTH WALL, 1st RADIATOR FROM EAST AT SOUTH WALL, SOUTH WALL, WEST WALL IN THE 1st ROOM FROM EAST LOCATED AT APT A, 2nd APARTMENT FROM NORTH AT EAST
ECB05/16/2025FAILURE TO MAINTAIN BUILDING IN A CODE COMPLIANT MANNER. NOTED AT EXP #3 OF PROPERTY A SECTION OF RETAINING WALL APPROX 20'-0" LENGTH X 15'-0" HEIGHT AND RUNNING PARALLEL TO ENTRANCE ROADWAY TO GWB IS IN DISREPNothing owed — awaiting certificate of correction
ECB03/06/20251RCNY 103-09(E). FAILURE TO FILE A RETAINING WALL CONDITION ASSESSMENTREPORT BY THE DEADLINE AS REQUIRED BY 1RCNY 103-09(E)(2) AND (5). TO DATE, THE DEPARTMENT HAS NOT RECIEVED A RETAINING WALL CONDITION ASSESSNothing owed — awaiting certificate of correction
ECB04/30/2020SURFACE BLOW DOWN NOT PIPED-COIL RELIEF DISCHARGE NOT PIPED-NO BODY DRAIN ON SAFETY VALVE-FIRE GASKET AT FRONT NEEDS REPLACEMENT-PIPING NOT PROPERLY SUPPORTED-GUARDS MISSING FROM WATER LEVEL GLASS AT COND. TANKNothing owed — awaiting certificate of correction
ECB08/20/2011FAILURE TO MAINTAIN BLDG IN CODE-COMPLIANT MANNER. NOTED @ NORTH SIDE EXTENSION FIRE BALCONY MADE OF MASONRY HAS DEFECTIVE SUPPORT BEAMS W/MISSING CONCRETE FIREPROOFING @ TIME OF INSPECTION. REMEDY: MAKE SAFENothing owed — awaiting certificate of correction