← Back
Two family brick
1344 EAST 16 STREET
BROOKLYN · Midwood · BIN 3180925
💬 Discuss this project
1940Year Built
2Stories
B1Building Class
R5BZoning
1,592 sfGross Floor Area
2Units
Two family brick · 1,498 sf lot · 1.06 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalPlumbing
Floor 14p · 1 filing · 19 docs
Sub-Basement1 filing · 19 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KL INNOVATIVE DESIGN INC209/06/2019
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
BASIC GROUPS403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PIPESTYLISTS, INCPlumbing407/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
KL INNOVATIVE DESIGN INC7225209/06/2019
Building Lifecycle
All (14)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (10)
09/26/2019
Signed off — Alteration
REMOVE AND INSTALL NEW BOILER, HOT WATER HEATER ON 1ST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00198491-I1
09/23/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
HO YIN LAW
09/23/2019
Special inspection requirement — Energy Code Compliance Inspections
HO YIN LAW
09/23/2019
Special inspection requirement — HVAC and service water heating system controls
HO YIN LAW
09/23/2019
Special inspection requirement — HVAC insulation and sealing
HO YIN LAW
09/23/2019
Special inspection requirement — HVAC and service water heating equipment
HO YIN LAW
09/06/2019
Filed — Alteration
REMOVE AND INSTALL NEW BOILER, HOT WATER HEATER ON 1ST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00198491-P1
09/06/2019
Special inspection requirement — Fire-Resistant Penetrations and Joints
HO YIN LAW
09/06/2019
Special inspection requirement — Energy Code Compliance Inspections
HO YIN LAW
09/06/2019
Special inspection requirement — HVAC and service water heating equipment
HO YIN LAW
09/06/2019
Special inspection requirement — HVAC and service water heating system controls
HO YIN LAW
09/06/2019
Special inspection requirement — HVAC insulation and sealing
HO YIN LAW
07/24/2019
Permit issued — Plumbing
B00198491-I1-PL
07/23/2019
Filed — Alteration
REMOVE AND INSTALL NEW BOILER, HOT WATER HEATER ON 1ST FLOOR. NO CHANGE IN USE, EGRESS OR OCCUPANCY
B00198491-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offT & T PLUMBING INC07/24/2019
Nothing on file for this building.
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
09/23/2019Fire-Resistant Penetrations and JointsHO YIN LAWspecial
09/23/2019Energy Code Compliance InspectionsHO YIN LAWprogress
09/23/2019HVAC and service water heating system controls HO YIN LAWenergy_progress
09/23/2019HVAC insulation and sealing HO YIN LAWenergy_progress
09/23/2019HVAC and service water heating equipment HO YIN LAWenergy_progress
09/06/2019Fire-Resistant Penetrations and JointsHO YIN LAWspecial
09/06/2019Energy Code Compliance InspectionsHO YIN LAWprogress
09/06/2019HVAC and service water heating equipment HO YIN LAWenergy_progress
09/06/2019HVAC and service water heating system controls HO YIN LAWenergy_progress
09/06/2019HVAC insulation and sealing HO YIN LAWenergy_progress
▾Documents — 19 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00198491-I1Request digital key ↗
08/15/2026B00198491-P1Request digital key ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature8
08/29/2026B00198491-P1Open ↗
08/29/2026B00198491-P1Open ↗
08/29/2026B00198491-P1Open ↗
Showing 3 of 8 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00198491-I1Open ↗
08/13/2026B00198491-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/29/2026B00198491-P1Open ↗
08/28/2026B00198491-I1Open ↗
▸Safety & Tenant Protection2
▸DOB NOWTenant Protection Plan2
08/13/2026B00198491-I1Open ↗
08/13/2026B00198491-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00198491-I1Open ↗
08/13/2026B00198491-P1Open ↗
▸Energy Compliance1
▸DOB NOWPreliminary Commissioning Report Certification1
08/13/2026B00198491-I1Open ↗