← Back
Two stories - detached, small or mid-size
135-16 134 PLACE
QUEENS · South Ozone Park · BIN 4257497
💬 Discuss this project
1901Year Built
2Stories
A1Building Class
R3-2Zoning
3,037 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 6,520 sf lot · 0.47 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbingFire Protection
Permit Issued — active, not yet Signed-off
Roof1p · 2 filings · 6 docs
Floor 2Under Construction9p · 1 filing · 20 docs
Floor 1Under Construction9p · 1 filing · 20 docs
CellarUnder Construction11p · 3 filings · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
04/12/2019$945K—Private party → Private party$311/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
KENNY LEE ARCHITECT409/24/2025
JOSE A VELASQUEZ, PE107/20/2023
M.INT'L ENGINEERING PLLC303/02/2021
GREEN DESIGN107/10/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JOSE A VELASQUEZ PE203/21/2026
YBL NY603/21/2026
KORMAN DESIGN & BUILD803/21/2026
BRIAN T OCONNOR203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOSHUA CONSTRUCTION CORPGeneral Contractor207/08/2026
BT'S PLUMBING AND HEATINGPlumbing108/04/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
INTERNATIONAL GEOTEHCNICA1795209/24/2025
TRIANGLE INSPECTION & TES7495109/24/2025
M. INT'L ENGINEERING PLLC3129303/02/2021
Building Lifecycle
All (68)Filed (9)Permit Issued (3)Inspection (3)Objection (27)Special Inspection (26)
08/19/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
08/11/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
08/03/2026
Permit issued — Plumbing
Q01277587-S1-PL
07/20/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
06/23/2026
Permit issued — General Construction
Q01277587-I1-GC
06/15/2026
Permit issued — Construction Fence
Q01277587-S3-FN
12/29/2025
Objection resolved — Addressed
12/29/2025
Objection resolved — Addressed
12/23/2025
Objection raised — Admin
12/23/2025
Objection resolved — Addressed
12/09/2025
Objection resolved — Addressed
11/11/2025
Objection raised — Cost
11/11/2025
Objection resolved — Addressed
11/11/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/29/2025
Objection resolved — Addressed
10/24/2025
Objection raised — Scope
10/24/2025
Objection raised — Plumbing
10/24/2025
Objection raised — Plumbing
10/24/2025
Objection raised — Scope
10/22/2025
Objection resolved — Addressed
10/22/2025
Special inspection requirement — Permanent certificate
MICHAEL KARANTINIDIS, P.E.
10/22/2025
Special inspection requirement — Metering
MICHAEL KARANTINIDIS, P.E.
10/22/2025
Special inspection requirement — Maintenance information
MICHAEL KARANTINIDIS, P.E.
10/15/2025
Objection raised — Zoning
10/15/2025
Objection raised — Energy
10/15/2025
Objection raised — Scope
09/24/2025
Filed — Alteration CO
INSTALLATION OF GAS EQUIPMENT & APPLIANCES AND PLUMBING FIXTURES TO OBTAIN CO OF 2 DWELLING UNIT HOUSE
Q01277587-S3
09/24/2025
Filed — Alteration CO
INSTALLATION OF GAS EQUIPMENT & APPLIANCES AND PLUMBING FIXTURES TO OBTAIN CO OF 2 DWELLING UNIT HOUSE
Q01277587-S1
09/24/2025
Filed — Alteration CO
INSTALLATION OF GAS EQUIPMENT & APPLIANCES AND PLUMBING FIXTURES TO OBTAIN CO OF 2 DWELLING UNIT HOUSE
Q01277587-I1
09/24/2025
Filed — Alteration CO
INSTALLATION OF GAS EQUIPMENT & APPLIANCES AND PLUMBING FIXTURES TO OBTAIN CO OF 2 DWELLING UNIT HOUSE
Q01277587-S2
09/19/2025
Special inspection requirement — Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention Facilities
Rajasekhar Sakhamuri
09/19/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Air barrier - visual inspection
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Fenestration air leakage
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — HVAC-R and service water heating system controls
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Concrete - Cast-In-Place
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Masonry
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Interior lighting power
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Energy Code Compliance Inspections
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — HVAC-R and service water heating equipment
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Fenestration areas
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Electric vehicle service equipment requirements
MICHAEL KARANTINIDIS, P.E.
09/16/2025
Special inspection requirement — Insulation placement and R values
MICHAEL KARANTINIDIS, P.E.
08/01/2023
Objection raised — Scope
07/20/2023
Filed — Alteration CO
CONVERTING FROM A ONE FAMILY TO A TWO FAMILY DWELLING. INSTALLING IN THE CELLAR A THREE FIXTURE BATHROOM, LAUNDRY AREA AND MINOR PARTITIONS.
Q08037739-I1
03/01/2023
Special inspection requirement — Fire-Resistance Rated Construction
03/01/2023
Special inspection requirement — Energy Code Compliance Inspections
12/05/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
11/10/2022
Special inspection requirement — Interior lighting power
11/10/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/11/2021
Objection raised — Admin
03/11/2021
Objection resolved — Addressed
03/11/2021
Objection raised — Structural
03/11/2021
Objection resolved — Addressed
Latest 60 of 68 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedBT'S PLUMBING AND HEATING08/03/2026
DOB NOWGeneral ConstructionPermit IssuedJOSHUA CONSTRUCTION CORP06/23/2026
DOB NOWConstruction FencePermit IssuedJOSHUA CONSTRUCTION CORP06/15/2026
BIS—ISSUEDA-1 STATE INC04/23/2018
BISPLISSUEDM & M PIPING AND HEATING01/08/2018
BIS—ISSUEDA-1 STATE INC10/31/2017
BISOTISSUEDN/A08/03/1998
BISOTISSUEDN/A01/31/1997
1 project · most recent 03/02/2021
FiledStatusContractorScope
03/02/2021———
1 project · most recent 09/24/2025
Gas Storm Water/Sanitary
FiledStatusContractorScope
09/24/2025Permit IssuedBT'S PLUMBING AND HEATINGGas, Storm, Water/Sanitary
2 projects · most recent 06/10/2026
General Wiring
FiledStatusContractorScope
06/10/2026Permit IssuedSUPREME ELECTRIC CORPGeneral Wiring
01/26/2018CompleteRAMDEEN'S ELEC. CONTR.CORGeneral Wiring
1 project · most recent 09/24/2025
Fence
FiledStatusContractorScope
09/24/2025Permit IssuedBT'S PLUMBING AND HEATINGFence
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
08/19/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
08/11/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/20/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 26
DateRequirementInspectorRole
10/22/2025Permanent certificateMICHAEL KARANTINIDIS, P.E.energy_progress
10/22/2025MeteringMICHAEL KARANTINIDIS, P.E.energy_progress
10/22/2025Maintenance informationMICHAEL KARANTINIDIS, P.E.energy_progress
09/19/2025Soil Percolation Test - Private On-Site Storm Water Drainage Disposal Systems, and Detention FacilitiesRajasekhar Sakhamurispecial
09/19/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationMICHAEL KARANTINIDIS, P.E.special
09/16/2025Air barrier - visual inspectionMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Fenestration air leakageMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025HVAC-R and service water heating system controlsMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Concrete - Cast-In-PlaceMICHAEL KARANTINIDIS, P.E.special
09/16/2025Fire-Resistant Penetrations and JointsMICHAEL KARANTINIDIS, P.E.special
09/16/2025MasonryMICHAEL KARANTINIDIS, P.E.special
09/16/2025Energy Code Compliance InspectionsMICHAEL KARANTINIDIS, P.E.progress
09/16/2025Interior lighting powerMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Fire-Resistant Penetrations and JointsMICHAEL KARANTINIDIS, P.E.special
09/16/2025Energy Code Compliance InspectionsMICHAEL KARANTINIDIS, P.E.progress
09/16/2025HVAC-R and service water heating equipmentMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025HVAC-R and service water piping design and insulationMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Fenestration areasMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Fenestration and door U-factor and product ratingsMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Electric vehicle service equipment requirementsMICHAEL KARANTINIDIS, P.E.energy_progress
09/16/2025Insulation placement and R valuesMICHAEL KARANTINIDIS, P.E.energy_progress
03/01/2023Fire-Resistance Rated Construction—progress
03/01/2023Energy Code Compliance Inspections—progress
12/05/2022Structural Stability – Alterations of existing buildings—special
11/10/2022Interior lighting power—energy_progress
Latest 25 of 26.
▾Documents — 129 on file (BIS + DOB NOW)
▸Plans & Drawings8
▸DOB NOWPlans/Sketch4
08/18/2026Q01277587-I1Request digital key ↗
08/18/2026Q01277587-S3Request digital key ↗
08/18/2026Q01277587-S1Request digital key ↗
Showing 3 of 4 on file for this type
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/27/2026Q00415937-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Plumbing1
08/27/2026Q00415935-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Place of Assembly1
08/28/2026Q00357785-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Sprinkler1
08/15/2026Q00415939-I1Request digital key ↗
▸Applications & Permits19
▸BISPLAN / WORK APPROVAL APPLICATION14
03/11/2022421794605Open ↗
10/19/2021421794605Open ↗
11/05/2020421794605Open ↗
Showing 3 of 14 on file for this type
▸BISWORK PERMIT APPLICATION3
04/26/2018421522855Open ↗
01/09/2018421522855Open ↗
10/26/2017421522855Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
01/18/2018421522855Open ↗
▸BISPLAN - WORK & PERMITS - SUPPPORTING DOCUMENTATION1
03/26/2018410089693Open ↗
▸Zoning, Tax Lot & Property Records4
▸BISZONING DIAGRAM2
01/12/2022421794605Open ↗
08/17/2017421522855Open ↗
▸BISADDRESS: NEW HOUSE NUMBER APPROVED1
01/10/2019421522855Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q08037739-I1Open ↗
▸Seals & Professional Certifications38
▸DOB NOWProgress Inspector Seal & Signature15
09/01/2026Q01277587-S1Open ↗
09/01/2026Q01277587-S1Open ↗
09/01/2026Q01277587-S1Open ↗
Showing 3 of 15 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature9
08/28/2026Q00357785-I1Open ↗
08/27/2026Q00415939-I1Open ↗
08/27/2026Q00415937-I1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature6
09/01/2026Q01277587-S1Open ↗
09/01/2026Q01277587-S1Open ↗
09/01/2026Q01277587-S1Open ↗
Showing 3 of 6 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
08/29/2019421794605Open ↗
08/29/2019421794605Open ↗
07/03/2017421522855Open ↗
Showing 3 of 4 on file for this type
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/12/2019440556453Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
05/08/2019440546241Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
07/12/2019440556453Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/12/2019440556453Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
07/03/2017421522855Open ↗
▸Safety & Tenant Protection3
▸BISSTREET TREE CHECKLIST2
08/29/2019421794605Open ↗
07/03/2017421522855Open ↗
▸DOB NOWStreet Tree Checklist1
08/13/2026Q01277587-I1Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report8
08/27/2026Q00415937-I1Open ↗
08/27/2026Q00415935-I1Open ↗
08/15/2026Q00415939-I1Open ↗
Showing 3 of 8 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
04/01/2008410089693Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/03/2017421522855Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
01/12/2022421794605Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
07/03/2017421522855Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/10/2019421522855Open ↗
▸Inspections & Test Reports8
▸BISTECHNICAL REPORT: RESPONSIBILITY5
01/12/2022421794605Open ↗
01/12/2022421794605Open ↗
07/12/2019440556453Open ↗
Showing 3 of 5 on file for this type
▸BISINSPECTION REPORT - SUPPORTING DOCUMENTATION1
01/10/2019421522855Open ↗
▸BISSOIL REPORT1
01/12/2022421794605Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
01/12/2022421794605Open ↗
▸Approvals, Objections & Sign-offs10
▸BISSCHEDULE A - OCCUPANCY / USE6
10/19/2021421794605Open ↗
08/29/2019421794605Open ↗
08/10/2017421522855Open ↗
Showing 3 of 6 on file for this type
▸BISADMINISTRATIVE OBJECTIONS2
07/03/2017421522855Open ↗
04/01/2008410089693Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
02/01/2019421522855Open ↗
01/10/2019421522855Open ↗
▸Cost, Insurance & Ownership6
▸BISCOST AFFIDAVIT5
08/29/2019421794605Open ↗
07/12/2019440556453Open ↗
05/10/2019440546241Open ↗
Showing 3 of 5 on file for this type
▸BISDEPT OF FINANCE VERIFICATION1
01/10/2019421522855Open ↗
▸Filing & Intake Forms12
▸BISBOROUGH INTAKE FORM4
05/19/2020440546241Open ↗
01/10/2019421522855Open ↗
03/26/2018410089693Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET3
08/29/2019421794605Open ↗
07/03/2017421522855Open ↗
04/01/2008410089693Open ↗
▸BISADDITIONAL INFORMATION3
01/12/2022421794605Open ↗
01/10/2019421522855Open ↗
02/28/2018421522855Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET2
07/12/2019440556453Open ↗
05/08/2019440546241Open ↗
▸Other Documents7
▸BISPLOT DIAGRAM4
01/12/2022421794605Open ↗
08/29/2019421794605Open ↗
01/10/2019421522855Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWProperty Ownership Certification2
08/13/2026Q08037739-I1Open ↗
08/13/2026Q01277587-I1Open ↗
▸DOB NOWFinal Survey1
08/13/2026Q08037739-I1Open ↗