← Back
Office with apartments (no commercial)
135-18 LIBERTY AVENUE
QUEENS · South Ozone Park · BIN 4204944
💬 Discuss this project
1931Year Built
2Stories
O8Building Class
R6BZoning
2,520 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Office with apartments (no commercial) · 2,159 sf lot · 1.17 FAR built · Flood zone X
Locations of Work
ElectricalMechanicalPlumbingEquipment
Roof1p · 1 filing · 3 docs
Floor 22p · 1 filing · 17 docs
Floor 1
Cellar1p · 1 filing · 17 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
NEW AMERICAN CONSTRUCTION INC407/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
12/19/2025$985K—LAW OFFICES OF DOLLY Z. HASSAN, PH.D., P.C. → 135-18 LIBERTY LLC$391/sf building
04/15/2019$800K—BRITA SPECIALTIES INC. → LAW OFFICES OF DOLLY Z. HASSAN, PH.D.,P.C.$317/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
DRAFT MASTER ENGINEERING PC312/19/2025
GREEN DESIGN107/03/2018
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ATLANTIC BUILDING SUPPLY INC.203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NEW AMERICAN CONSTRUCTION INCGeneral Contractor107/08/2026
G.M.A. PLUMBING & HEATINGPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
DRAFT MASTER ENGINEERING701312/19/2025
Building Lifecycle
All (34)Filed (4)Permit Issued (2)Signed Off (2)Violation (8)Inspection (3)Objection (2)Special Inspection (13)
03/30/2026
Signed off — Alteration
INSTALLATION NEW GAS NAVIEN CONDENSING GAS COMBINATION BOILER
Q00670130-I1
02/17/2026
Special inspection requirement — Maintenance information
ANTHONY GURBALL
02/17/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY GURBALL
02/17/2026
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY GURBALL
02/17/2026
Special inspection requirement — HVAC-R and service water heating equipment
ANTHONY GURBALL
02/17/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
ANTHONY GURBALL
02/17/2026
Special inspection requirement — HVAC-R and service water heating system controls
ANTHONY GURBALL
02/02/2026
Objection resolved — Addressed
01/13/2026
Objection raised — Scope
12/30/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
12/19/2025
Filed — Alteration
INSTALLATION NEW GAS NAVIEN CONDENSING GAS COMBINATION BOILER
Q00670130-P3
12/19/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ANTHONY GURBALL
12/19/2025
Special inspection requirement — Energy Code Compliance Inspections
ANTHONY GURBALL
12/19/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
ANTHONY GURBALL
12/19/2025
Special inspection requirement — Maintenance information
ANTHONY GURBALL
12/19/2025
Special inspection requirement — HVAC-R and service water heating system controls
ANTHONY GURBALL
12/19/2025
Special inspection requirement — HVAC-R and service water heating equipment
ANTHONY GURBALL
07/12/2023
Violation issued (ECB, closed)
Construction
04/25/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/20/2022
Filed — Alteration
INSTALLATION NEW GAS NAVIEN CONDENSING GAS COMBINATION BOILER
Q00670130-P1
05/12/2022
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/22/2022
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
04/01/2022
Permit issued — Plumbing
Q00670130-I1-PL
02/25/2022
Filed — Alteration
INSTALLATION NEW GAS NAVIEN CONDENSING GAS COMBINATION BOILER
Q00670130-I1
04/22/2019
Signed off — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE.
Q00058910-I1
07/05/2018
Permit issued — Sidewalk Shed
Q00058910-I1-SH
07/03/2018
Filed — Alteration
PROPOSED INSTALLATION OF HEAVY DUTY SIDEWALK SHED FOR REMEDIAL REPAIRS AS PER PLANS. NO CHANGE IN USE OCCUPANCY OR EGRESS UNDER THIS APPLICATION. LIVE LOAD 300 PER SQUARE FEET. SIDEWALK SHED SHALL COMPLY WITH CHAPTER # 33 OF THE 2014 CODE.
Q00058910-I1
07/03/2018
Special inspection requirement — Final
BRIAN T. O'CONNOR
01/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
03/26/2002
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/04/1998
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
02/10/1997
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
08/29/1995
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
06/28/1993
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offG.M.A. PLUMBING & HEATING04/01/2022
DOB NOWSidewalk ShedSigned-offNEW AMERICAN CONSTRUCTION07/05/2018
BISPLISSUEDDUNDEE PLBG & HTG INC03/22/2019
BIS—ISSUEDALI & SON IMPROVEMENT INC03/20/2019
3 projects · most recent 07/09/2019
General Wiring
FiledStatusContractorScope
07/09/2019CompleteV&B ELECTRICAL CONTNG INCGeneral Wiring
07/03/2018CompleteRICHARD NEU—
04/10/2018CompleteWILLDAN ELECTRICAL OF NY—
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
12/30/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
05/12/2022Pass-Final PL - Up to 3 Requested FloorsPassView ↗
04/22/2022Certified Gas-Gas-Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
02/17/2026Maintenance informationANTHONY GURBALLenergy_progress
02/17/2026Fire-Resistant Penetrations and JointsANTHONY GURBALLspecial
02/17/2026Energy Code Compliance InspectionsANTHONY GURBALLprogress
02/17/2026HVAC-R and service water heating equipmentANTHONY GURBALLenergy_progress
02/17/2026HVAC-R and service water piping design and insulationANTHONY GURBALLenergy_progress
02/17/2026HVAC-R and service water heating system controlsANTHONY GURBALLenergy_progress
12/19/2025Fire-Resistant Penetrations and JointsANTHONY GURBALLspecial
12/19/2025Energy Code Compliance InspectionsANTHONY GURBALLprogress
12/19/2025HVAC-R and service water piping design and insulationANTHONY GURBALLenergy_progress
12/19/2025Maintenance informationANTHONY GURBALLenergy_progress
12/19/2025HVAC-R and service water heating system controlsANTHONY GURBALLenergy_progress
12/19/2025HVAC-R and service water heating equipmentANTHONY GURBALLenergy_progress
07/03/2018FinalBRIAN T. O'CONNORprogress
▾Documents — 47 on file (BIS + DOB NOW)
▸Plans & Drawings4
▸DOB NOWPlans/Sketch4
08/28/2026Q00058910-I1Request digital key ↗
08/18/2026Q00670130-P1Request digital key ↗
08/18/2026Q00670130-I1Request digital key ↗
Showing 3 of 4 on file for this type
▸Applications & Permits5
▸BISPLAN / WORK APPROVAL APPLICATION2
06/14/2019421685297Open ↗
02/14/2019421685297Open ↗
▸BISWORK PERMIT APPLICATION2
03/27/2019421685297Open ↗
03/26/2019421685297Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
05/02/2019421685297Open ↗
▸Seals & Professional Certifications12
▸DOB NOWProgress Inspector Seal & Signature5
08/23/2026Q00670130-P3Open ↗
08/23/2026Q00670130-P3Open ↗
08/23/2026Q00058910-I1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature4
08/28/2026Q00058910-I1Open ↗
08/18/2026Q00670130-P1Open ↗
08/18/2026Q00670130-I1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
08/23/2026Q00670130-P3Open ↗
08/22/2026Q00670130-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
03/26/2019421685297Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE1
01/23/2019421685297Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
02/15/2019421685297Open ↗
▸BISTenant Protection Plan and Notes1
02/15/2019421685297Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/18/2026Q00670130-P3Open ↗
08/18/2026Q00670130-I1Open ↗
08/18/2026Q00670130-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/23/2018421685297Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
02/15/2019421685297Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
09/13/2019421685297Open ↗
▸DOB NOWEN2: As Built Energy Analysis1
08/13/2026Q00670130-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
09/24/2019421685297Open ↗
09/13/2019421685297Open ↗
▸BISSCHEDULE A - OCCUPANCY / USE1
02/14/2019421685297Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT3
09/13/2019421685297Open ↗
02/15/2019421685297Open ↗
11/23/2018421685297Open ↗
▸BISDEPT OF FINANCE VERIFICATION2
09/13/2019421685297Open ↗
02/15/2019421685297Open ↗
▸Filing & Intake Forms6
▸BISADDITIONAL INFORMATION4
09/13/2019421685297Open ↗
09/13/2019421685297Open ↗
06/14/2019421685297Open ↗
Showing 3 of 4 on file for this type
▸BISEFILING COVER SHEET1
12/03/2018421685297Open ↗
▸BISBOROUGH INTAKE FORM1
05/02/2019421685297Open ↗
▸Other Documents2
▸BISPLOT DIAGRAM2
02/15/2019421685297Open ↗
11/23/2018421685297Open ↗