← Back
Two family frame
135-28 126 STREET
QUEENS · South Ozone Park · BIN 4453760
💬 Discuss this project
1996Year Built
2Stories
B2Building Class
R3-2Zoning
2,350 sfGross Floor Area
2Units
8 Open Violations 7 unresolved · 1 paperwork only ▸FDNY Report ↗
Two family frame · 4,000 sf lot · 0.59 FAR built · Flood zone X
Locations of Work
Electrical
Permit Issued — active, not yet Signed-off
RoofUnder Construction1p · 2 filings · 14 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC101/19/2026
GREEN RIVER ENVIRONMENTAL ENGINEERI207/29/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACA ASSOCIATES103/21/2026
NY State Solar LLC403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
NYSS LLCGeneral Contractor303/21/2026
TRINITY SOLAR LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
BITOPI CONSULTANTS LLC7036101/19/2026
GREEN RIVER ENVIRONMENTAL7841207/29/2025
Building Lifecycle
All (26)Filed (3)Permit Issued (2)Signed Off (1)Violation (10)Special Inspection (10)
01/27/2026
Permit issued — Solar
Q01347836-I1-SL
01/19/2026
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01347836-I1
07/30/2025
Signed off — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01195439-I1
07/30/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
07/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
07/30/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
07/30/2025
Special inspection requirement — Final
ROBERT MASONE
07/30/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
07/29/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01195439-P1
07/29/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
07/29/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
07/29/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
07/29/2025
Special inspection requirement — Final
ROBERT MASONE
07/29/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
03/17/2025
Permit issued — Solar
Q01195439-I1-SL
03/14/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS.
Q01195439-I1
12/08/2015
Violation issued (ECB, open)
Construction
04/09/2014
Violation issued (HPD, open)
C
04/09/2014
Violation issued (HPD, open)
A
04/09/2014
Violation issued (HPD, open)
B
04/09/2014
Violation issued (HPD, open)
A
04/09/2014
Violation issued (HPD, open)
B
04/09/2014
Violation issued (HPD, open)
A
04/09/2014
Violation issued (HPD, open)
B
08/05/1999
Violation issued (ECB, closed)
Quality of Life
08/05/1999
Violation issued (ECB, closed)
Quality of Life
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedTRINITY SOLAR LLC01/27/2026
DOB NOWSolarSigned-offNYSS LLC03/17/2025
BIS—ISSUEDMASTER CONTRACTORS INC11/01/1996
2 projects · most recent 01/15/2026
FiledStatusContractorScope
01/15/2026CancelledREDLINE ELECTRIC INC—
03/14/2025CompleteNY SOLAR ELECTRICAL LLC—
1 project · most recent 01/19/2026
FiledStatusContractorScope
01/19/2026Permit IssuedTRINITY SOLAR LLC20 panels, 8.2 kw, 1,530 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 10
DateRequirementInspectorRole
07/30/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
07/30/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
07/30/2025Energy Code Compliance InspectionsROBERT MASONEprogress
07/30/2025FinalROBERT MASONEprogress
07/30/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
07/29/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
07/29/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
07/29/2025Energy Code Compliance InspectionsROBERT MASONEprogress
07/29/2025FinalROBERT MASONEprogress
07/29/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
▾Documents — 14 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/20/2026Q01195439-I1Request digital key ↗
08/20/2026Q01195439-P1Request digital key ↗
08/17/2026Q01347836-I1Request digital key ↗
▸Seals & Professional Certifications9
▸DOB NOWProgress Inspector Seal & Signature4
08/30/2026Q01195439-I1Open ↗
08/30/2026Q01195439-I1Open ↗
08/28/2026Q01195439-P1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/20/2026Q01195439-P1Open ↗
08/20/2026Q01195439-I1Open ↗
08/17/2026Q01347836-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/30/2026Q01195439-I1Open ↗
08/28/2026Q01195439-P1Open ↗
▸Environmental & Asbestos1
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/17/2026Q01347836-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01195439-I1Open ↗