← Back
Two family frame
1352 WEST 6 STREET
BROOKLYN · Bensonhurst · BIN 3173320
💬 Discuss this project
1925Year Built
2Stories
B2Building Class
R5BZoning
2,360 sfGross Floor Area
2Units
Two family frame · 2,483 sf lot · 0.95 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 24p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Cellar5p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/24/2019$1.4M—— → —$576/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SAFWAYATLANTIC208/21/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
A PLUS DESIGN INC.403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
CATMAN PLUMBING INCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A PLUS DESIGN INC6615208/21/2020
Building Lifecycle
All (16)Filed (2)Permit Issued (1)Signed Off (1)Special Inspection (12)
09/16/2020
Signed off — Alteration
B00284408-I1
08/26/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
PENG LIU
08/26/2020
Special inspection requirement — Energy Code Compliance Inspections
PENG LIU
08/26/2020
Special inspection requirement — HVAC and service water heating equipment
PENG LIU
08/26/2020
Special inspection requirement — HVAC insulation and sealing
PENG LIU
08/26/2020
Special inspection requirement — Maintenance information
PENG LIU
08/26/2020
Special inspection requirement — HVAC and service water heating system controls
PENG LIU
08/21/2020
Filed — Alteration
B00284408-P1
02/19/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
PENG LIU
02/19/2020
Special inspection requirement — Energy Code Compliance Inspections
PENG LIU
02/19/2020
Special inspection requirement — HVAC and service water heating equipment
PENG LIU
02/19/2020
Special inspection requirement — HVAC and service water heating system controls
PENG LIU
02/19/2020
Special inspection requirement — Maintenance information
PENG LIU
02/19/2020
Special inspection requirement — HVAC insulation and sealing
PENG LIU
01/03/2020
Permit issued — Plumbing
B00284408-I1-PL
12/26/2019
Filed — Alteration
B00284408-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCATMAN PLUMBING INC01/03/2020
1 project · most recent 12/17/2019
General Wiring
FiledStatusContractorScope
12/17/2019CompleteJ Y ELECTRIC INCGeneral Wiring
▾Special Inspection Requirements (DOB NOW) — 12
DateRequirementInspectorRole
08/26/2020Fire-Resistant Penetrations and JointsPENG LIUspecial
08/26/2020Energy Code Compliance InspectionsPENG LIUprogress
08/26/2020HVAC and service water heating equipment PENG LIUenergy_progress
08/26/2020HVAC insulation and sealing PENG LIUenergy_progress
08/26/2020Maintenance informationPENG LIUenergy_progress
08/26/2020HVAC and service water heating system controls PENG LIUenergy_progress
02/19/2020Fire-Resistant Penetrations and JointsPENG LIUspecial
02/19/2020Energy Code Compliance InspectionsPENG LIUprogress
02/19/2020HVAC and service water heating equipment PENG LIUenergy_progress
02/19/2020HVAC and service water heating system controls PENG LIUenergy_progress
02/19/2020Maintenance informationPENG LIUenergy_progress
02/19/2020HVAC insulation and sealing PENG LIUenergy_progress
▾Documents — 35 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing2
09/02/2026B00284408-I1Request digital key ↗
08/15/2026B00284408-P1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
12/13/2019321973860Open ↗
▸BISWORK PERMIT APPLICATION1
12/13/2019321973860Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWRestrictive Declaration/Easement 12
08/13/2026B00284408-I1Open ↗
08/13/2026B00284408-P1Open ↗
▸Seals & Professional Certifications17
▸DOB NOWProgress Inspector Seal & Signature10
08/26/2026B00284408-P1Open ↗
08/26/2026B00284408-P1Open ↗
08/26/2026B00284408-P1Open ↗
Showing 3 of 10 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026B00284408-I1Open ↗
08/13/2026B00284408-P1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/26/2026B00284408-P1Open ↗
08/26/2026B00284408-I1Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
12/13/2019321973860Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
12/13/2019321973860Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
12/13/2019321973860Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026B00284408-I1Open ↗
08/13/2026B00284408-P1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
12/13/2019321973860Open ↗
▸Energy Compliance3
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
09/23/2020321973860Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
09/23/2020321973860Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS1
12/13/2019321973860Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
09/23/2020321973860Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
09/23/2020321973860Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT1
12/13/2019321973860Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
09/23/2020321973860Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
01/22/2021321973860Open ↗
▸BISEFILING COVER SHEET1
12/13/2019321973860Open ↗