← Back
BuildNYC
Two stories - detached, small or mid-size
136-05 KEW GARDENS ROAD
QUEENS · Kew Gardens · BIN 4206288
💬 Discuss this project
1920Year Built
2Stories
A1Building Class
R6Zoning
1,288 sfGross Floor Area
1Units
19 Active Violations ▸FDNY Report ↗
Two stories - detached, small or mid-size · Owner of record: 136 Kew NY · 2,850 sf lot · 0.45 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalFire ProtectionGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Site & exterior2p · 1 filing · 11 docs
Filed — no permit issuedProposed a 7-story Residential Building49p · 1 filing · 10 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/28/2024$998K—QUEENS KEW INC. → 136 KEW NY LLC$775/sf building
05/12/2022$820K—Private party → QUEENS KEW INC$637/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
A&B World Consulting212/29/2025
Tan Architect203/28/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Enkay Design Consulting203/21/2026
YBL NY403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Dyker SolutionsScaffold104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
A&B World Consulting5704111/18/2024
Building Lifecycle
08/21/2026
Observed a closed jobsite with an installed construction fence along the property line to protect the public from proposed demolition of a 2-story…
ECB violation · open
07/15/2026
Permit expired, never signed off — Construction Fence
The city's record still shows this permit as issued, with no sign-off on its filing
Q01123906-S1-FN
03/09/2026
Permit issued — Construction Fence
Q01123906-S1-FN
02/04/2026
Objection resolved — Addressed
02/03/2026
Objection resolved — Addressed
67 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedDyker Solutions03/09/2026
1 project · most recent 03/28/2025
Storm Water/Sanitary
FiledStatusContractorScope
03/28/2025——Storm, Water/Sanitary
1 project · most recent 12/29/2025
Fence
FiledStatusContractorScope
12/29/2025Permit IssuedDyker SolutionsFence
▾Special Inspection Requirements (DOB NOW) — 34
DateRequirementInspectorRole
03/28/2025Air barrier — testing —energy_progress
03/28/2025Lighting controls—energy_progress
03/28/2025Electrical motors and elevators—energy_progress
03/28/2025Subsurface Investigations (Borings/Test Pits)—special
03/28/2025Metering—energy_progress
10/08/2024Structural Stability – Alterations of existing BuildingsAlexander Bomsteinspecial
10/08/2024DemolitionAlexander Bomsteinspecial
10/03/2024Fenestration air leakage—energy_progress
04/01/2024Lighting in dwelling units—energy_progress
04/01/2024Exterior lighting power—energy_progress
04/01/2024Fenestration and door U-factor and product ratings—energy_progress
04/01/2024Maintenance information—energy_progress
04/01/2024Protection of exposed foundation insulation—energy_progress
04/01/2024Fenestration areas—energy_progress
04/01/2024Fire-Resistant Penetrations and Joints—special
04/01/2024Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
04/01/2024Energy Code Compliance Inspections—progress
04/01/2024Fire-Resistance Rated Construction—progress
04/01/2024Insulation placement and R values—energy_progress
04/01/2024Interior lighting power—energy_progress
04/01/2024Air barrier - visual inspection—energy_progress
11/04/2022Fire-Resistant Penetrations and Joints—special
11/04/2022Energy Code Compliance Inspections—progress
11/04/2022Fire-Resistance Rated Construction—progress
11/04/2022Fenestration air leakage—energy_progress
Latest 25 of 34.
36 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account