HPD05/07/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB11/13/2024FAILURE TO CERTIFY CORRECTION ON IMMEDIATELY HAZARDOUS (CLASS 1) ECB VIOLATION
DOB09/09/2024RE: PARTIAL VACATE ORDER DUE TO UNSAFE CONDITIONS INCLUDING DETSPALLI NDERSIDE OF THE GROUND FLOOR SLAB @ MULTIPLE LOCATIONSREMEDY,IMMED.COR D VACATE ENTIRE PARKING GARAGE
DOB09/09/2024PARTIAL VACATE ORDER DUE TO UNSAFE CONDITIONS INCLUDING DETERIORATED SPALLING AT THE UNDERSIDE OF THE GROUND FLOOR SLAB @ MULTIPLE LOCATIONS. THESE CONDITIONS HAVE MADE THE ENTIRE PARKING GARAGE STRUCTURE UNABLE TO BE OCCUPIED. REMEDY, IMMEDIATELY CORDON OFF AND VACATE ENTIRE PARKING GARAGE
ECB09/04/202428-323.8 AND RCNY 103-13(5). FAILURE TO SECURE PUBLIC SAFETY AND/OR MAKE THE BUILDING STRUCTURE AND APPURTENANCES CONFORM TO THE PROVISIONS OF THE ADMINISTRATIVE CODE AFTER UNSAFE NOTIFICATION FILED BY QPSI UNS$2K due
DOB09/04/2024EMERGENCY WORK ORDER DUE DEFECTIVE PARKING STRUCTURE.NOTE:AT THE TIME OF INSPECTION OBSERVED SPALLING AND CRACKED CONCRETE SLAB/BEAMS AT MULTIPLE LOCATION. REMEDY:IMMEDIATELY PROVIDE SAFETY MEASURE TO SECURE/PROTECT THE PUBLIC AND REMOVE ALL LOOSE MATERIALS
HPD06/10/2024§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE INTERCOM SYSTEM AT BUILDING VESTIBULE TO RETURN BUZZER AT NORTH WALL IN THE PRIVATE HALLWAY LOCATED AT APT 3E, 3rd STORY, 3rd APARTMENT FROM WEST AT NORTH
DOB05/31/2018FAILED TO FILE FISP CYCLE 8A TECHNICAL REPORT BY 02/21/2017
DOB11/02/2015FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/02/2015FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
DOB05/30/2014VIO ISSUED TO ELEVATOR - FAIL TO CORRECT DEFECTS ON 2012 CAT 1 INSP/TST
DOB11/13/2012V-DOB VIOLATION - ACTIVE
DOB11/13/2012V-DOB VIOLATION - ACTIVE
DOB11/13/2012V-DOB VIOLATION - ACTIVE
DOB05/03/2012FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
DOB01/01/2012FAILURE TO FILE BENCHMARKING REPORT OF ENERGY USE AS PER AD. CODE SEC. 28-309.4
HPD12/04/2009§ 27-2033 ADM CODE POST NOTICE, IN FORM APPROVED BY THE DEPARTMENT, STATING THE NAME AND LOCATION OF THE PERSON DESIGNATED BY THE OWNER TO HAVE KEY TO BUILDINGS HEATING SYSTEM SIGN MISSING AT PUBLIC HALL, 1st STORY
DOB02/27/2001V-DOB VIOLATION - ACTIVE
DOB02/27/2001V-DOB VIOLATION - ACTIVE
ECB06/08/2022THE BOILER SAFETY VALVES HAVE THE DISCHARGE PIPES MANIFOLDED TOGETHER/THE BOILER CONDENSATE DRAINS ARE MISSING THE CONDENSATE NEUTRALIZER/THERE IS AN OPENING IN THE BOILER ROOM DOOR/, MAINTAIN BOILER; CORRECT VNothing owed — awaiting certificate of correction
ECB10/18/200605A01/ 17M07/ 17D06/ 28D06/ 59Q03/ 64Q03/ (05-A-01) CAR DOOR SLAMS OPEN. (17-M-07) GIB MISSING ON 2ND FL (17-D-06) DOOR GIBS LOOSE ON 1ST FL & BASEMENT FL (28-D-06) DOOR OPERATOR COVER LAYING ON CAR TOP.Nothing owed — awaiting certificate of correction