Two stories - detached, small or mid-size
1368 KEARNEY AVENUE
BRONX · BIN 2075209
💬 Discuss this project
1899Year Built
2Stories
A1Building Class
R3AZoning
3,456 sfGross Floor Area
1Units
1 Open Violation 0 unresolved · 1 paperwork only ▸
Two stories - detached, small or mid-size · 8,750 sf lot · 0.39 FAR built · Flood zone X
Locations of Work
MechanicalPlumbing
Floor 215p · 2 filings · 17 docs
Floor 115p · 2 filings · 17 docs
Cellar15p · 2 filings · 17 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
02/08/2018$1.5M—— → —$444/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
LCK & ASSOCIATES211/23/2020
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
CITY CONSULTANT ENGINEERING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
DEMETRIOS KAOURISElectrical203/21/2026
JUNIOR CARTER MECH. CORPGeneral Contractor203/21/2026
EWAN PALMERElectrical103/21/2026
JUNIOR CARTER MECH. CORPPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
W.D.ROSS, R.A., P.C3758211/23/2020
Building Lifecycle
All (16)Filed (2)Permit Issued (2)Violation (3)Special Inspection (9)
03/11/2022
Permit issued — Plumbing
X00426726-I1-PL
11/22/2021
Permit issued — Mechanical Systems
X00420918-I1-MS
11/23/2020
Filed — Alteration
X00420918-I1
11/23/2020
Filed — Alteration
X00426726-I1
11/10/2020
Special inspection requirement — HVAC and service water heating system controls
WILLIAM ROSS
11/10/2020
Special inspection requirement — HVAC insulation and sealing
WILLIAM ROSS
11/10/2020
Special inspection requirement — HVAC and service water heating equipment
WILLIAM ROSS
11/10/2020
Special inspection requirement — Duct leakage testing
LINUS KORIEOCHA
11/10/2020
Special inspection requirement — Maintenance information
WILLIAM ROSS
10/28/2020
Special inspection requirement — Fire-Resistant Penetrations and Joints
WILLIAM ROSS
10/28/2020
Special inspection requirement — Final
WILLIAM ROSS
10/28/2020
Special inspection requirement — Energy Code Compliance Inspections
WILLIAM ROSS
10/28/2020
Special inspection requirement — Mechanical Systems
WILLIAM ROSS
08/08/2013
Violation issued (ECB, open)
Construction
01/28/2010
Violation issued (ECB, closed)
Unknown
09/25/2009
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedJUNIOR CARTER MECH. CORP03/11/2022
DOB NOWMechanical SystemsPermit IssuedELITE DK CONSTRUCTION LLC11/22/2021
BIS—ISSUEDWATERMARK CONTRACTORS INC06/22/2017
BISOTISSUEDCOVENTRY INTERIORS INC06/25/2010
BISEQISSUEDCOVENTRY INTERIORS INC06/25/2010
BISPLISSUEDRENEW PLUMBING CORP03/08/2010
BISOTISSUEDCOVENTRY INTERIORS INC03/02/2010
BISEQISSUEDCOVENTRY INTERIORS INC02/24/2010
BISMHISSUEDCOVENTRY INTERIORS INC02/24/2010
1 project · most recent 11/23/2020
Air Conditioning Systems Heating Systems
FiledStatusContractorScopeMake / Model / Capacity
11/23/2020Permit IssuedJUNIOR CARTER MECH. CORPAir Conditioning Systems, Heating Systems
Cooling
Luxaire LCJD6041S1C 60,000 BTU · Condensing Unit ×2
Magic-Aire DUC20H4AS1GBCM 130,000 BTU · Ahu ×1
Heating
Mitsubishi Electric MSY-GLI5NA 14,000 BTU · Ahu ×1
MUY-GLISNA 14,000 BTU · Heat Pump Outdoor ×1
2 projects · most recent 05/15/2022
General Wiring
FiledStatusContractorScope
05/15/2022Permit IssuedPRINCIPAL ELECTRICAL CORPGeneral Wiring
12/17/2021CompleteFUSION ELECTRIC, INC.General Wiring
▾Special Inspection Requirements (DOB NOW) — 9
DateRequirementInspectorRole
11/10/2020HVAC and service water heating system controls WILLIAM ROSSenergy_progress
11/10/2020HVAC insulation and sealing WILLIAM ROSSenergy_progress
11/10/2020HVAC and service water heating equipment WILLIAM ROSSenergy_progress
11/10/2020Duct leakage testing LINUS KORIEOCHAenergy_progress
11/10/2020Maintenance informationWILLIAM ROSSenergy_progress
10/28/2020Fire-Resistant Penetrations and JointsWILLIAM ROSSspecial
10/28/2020FinalWILLIAM ROSSprogress
10/28/2020Energy Code Compliance InspectionsWILLIAM ROSSprogress
10/28/2020Mechanical SystemsWILLIAM ROSSspecial
▾Documents — 83 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Plumbing Legalization1
08/25/2026X00426726-I1Request digital key ↗
▸DOB NOWPlans/Sketch - Mechanical Systems1
08/25/2026X00420918-I1Request digital key ↗
▸Applications & Permits17
▸BISPLAN / WORK APPROVAL APPLICATION9
06/11/2021220622985Open ↗
04/08/2020220046037Open ↗
01/27/2020220622985Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION8
06/23/2017220046037Open ↗
06/28/2010220031187Open ↗
06/28/2010220031187Open ↗
Showing 3 of 8 on file for this type
▸Zoning, Tax Lot & Property Records3
▸BISZONING DIAGRAM1
02/19/2010220031187Open ↗
▸BISZoning Diagram (ZD1)1
02/23/2010220031187Open ↗
▸BISZONING EXHIBIT I: CERTIFICATION1
10/28/2021220622985Open ↗
▸Seals & Professional Certifications20
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION7
01/27/2020220622985Open ↗
04/11/2018220259734Open ↗
04/11/2018220259734Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
08/31/2026X00420918-I1Open ↗
08/31/2026X00420918-I1Open ↗
08/31/2026X00420918-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/25/2026X00426726-I1Open ↗
08/13/2026X00420918-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026X00420918-I1Open ↗
08/31/2026X00420918-I1Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
10/07/2009220031187Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM1
10/07/2009220031187Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE B - PLUMBING1
10/07/2009220031187Open ↗
▸Safety & Tenant Protection11
▸BISEXCAVATION OR DEMOLITION: 5-DAY NOTICE3
03/01/2010220031187Open ↗
02/26/2010220031187Open ↗
02/26/2010220031187Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM2
08/17/2020220622985Open ↗
07/30/2020220622985Open ↗
▸BISSTREET TREE CHECKLIST2
01/27/2020220622985Open ↗
10/07/2009220031187Open ↗
▸DOB NOWTenant Protection Plan2
08/13/2026X00420918-I1Open ↗
08/13/2026X00426726-I1Open ↗
▸BISTenant Protection Plan and Notes1
04/11/2018220259734Open ↗
▸BISST-1 Street Tree Checklist1
01/25/2010220046037Open ↗
▸Environmental & Asbestos6
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
08/17/2020220622985Open ↗
01/27/2020220622985Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/25/2026X00426726-I1Open ↗
08/13/2026X00420918-I1Open ↗
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER1
01/25/2010220046037Open ↗
▸BISTHIS IS 'NOT AN ASBESTOS PROJECT'1
10/07/2009220031187Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
01/27/2020220622985Open ↗
04/11/2018220259734Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/31/2020220622985Open ↗
▸Inspections & Test Reports2
▸BISBORINGS - TEST PITS (TR-4) 27-7201
03/01/2010220031187Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/31/2020220622985Open ↗
▸Approvals, Objections & Sign-offs5
▸BISADMINISTRATIVE OBJECTIONS3
01/25/2010220046037Open ↗
01/22/2010220046037Open ↗
10/07/2009220031187Open ↗
▸BISSCHEDULE A - OCCUPANCY - USE1
01/25/2010220046037Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
01/16/2015220031187Open ↗
▸Cost, Insurance & Ownership5
▸BISCOST AFFIDAVIT4
07/18/2022220622985Open ↗
01/27/2020220622985Open ↗
04/11/2018220259734Open ↗
Showing 3 of 4 on file for this type
▸BISCOST AFFIDAVIT ESTIMATE: (PW3)1
07/30/2020220622985Open ↗
▸Filing & Intake Forms5
▸BISEFILING COVER SHEET4
01/27/2020220622985Open ↗
04/11/2018220259734Open ↗
04/11/2018220259734Open ↗
Showing 3 of 4 on file for this type
▸BISADDITIONAL INFORMATION1
08/17/2020220622985Open ↗
▸Other Documents3
▸BISSUSTAINABLE ROOF ZONE FORM1
10/28/2021220622985Open ↗
▸BISGARAGE PHOTO OF 1940 FROM NYC DEPT. OF RECORDS MUNICIPAL ARCHIVES1
07/14/2020220622985Open ↗
▸BISSANDBORMAP1
07/14/2020220622985Open ↗