← Back
One story - permanent living quarter
137-21 133 AVENUE
QUEENS · Baisley Park · BIN 4262253
💬 Discuss this project
1940Year Built
1Stories
A2Building Class
R3AZoning
768 sfGross Floor Area
1Units
10 Open Violations 9 unresolved · 1 paperwork only ▸FDNY Report ↗
One story - permanent living quarter · 4,000 sf lot · 0.19 FAR built · Flood zone X
Locations of Work
Plumbing
Floor 25p · 1 filing · 20 docs
Floor 15p · 1 filing · 20 docs
Cellar5p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
09/06/2024$736K—Private party → Private party$958/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
SOUTHERN CONSULTING ENGINEERING PC507/16/2026
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JARED ASSOCIATE CONSULTING803/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
R.N.K. ROMEO CONST INCGeneral Contractor107/08/2026
G.M.A. PLUMBING & HEATINGPlumbing107/08/2026
M & M PIPING AND HEATINGPlumbing106/28/2026
WASOFF PLBG & UTILITY COPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
S&S CONCRETE & SOIL TESTI1008204/10/2025
Building Lifecycle
All (78)Filed (5)Permit Issued (4)Violation (10)Inspection (11)Objection (18)Special Inspection (30)
09/16/2026
Objection resolved — Resolved
09/16/2026
Objection resolved — Resolved
07/16/2026
Filed — ALT-CO - New Building with Existing Elements to Remain
Plumbing work type for enlargement and conversion to a 2-family dwelling as per submitted drawing.
Q01121686-S2
07/16/2026
Objection resolved — Addressed
07/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/15/2026
Special inspection requirement — Sprinkler Systems
07/08/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
06/16/2026
Violation issued (ECB, open)
Construction
06/01/2026
Inspection — Certified Water and Sanitary-WS-Fixtures-Finish
Certified
View inspection ↗
05/21/2026
Objection raised — Zoning
05/04/2026
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
04/24/2026
Objection raised — Scope
03/27/2026
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/27/2026
Objection resolved — Addressed
01/07/2026
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
01/07/2026
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/02/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
10/02/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
10/02/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
10/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
10/02/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/10/2025
Permit issued — Plumbing
Q01121686-S1-PL
04/11/2025
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
04/11/2025
Special inspection requirement — Maintenance information
GLEN LANGER
04/11/2025
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
04/11/2025
Special inspection requirement — Metering
GLEN LANGER
04/11/2025
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
04/11/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
04/11/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
04/11/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
04/11/2025
Special inspection requirement — Permanent certificate
GLEN LANGER
04/10/2025
Filed — ALT-CO - New Building with Existing Elements to Remain
Plumbing work type for enlargement and conversion to a 2-family dwelling as per submitted drawing.
Q01121686-P1
04/10/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
GLEN LANGER
04/10/2025
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
GLEN LANGER
04/10/2025
Special inspection requirement — Energy Code Compliance Inspections
GLEN LANGER
04/10/2025
Special inspection requirement — HVAC-R and service water piping design and insulation
GLEN LANGER
04/10/2025
Special inspection requirement — HVAC-R and service water heating equipment
GLEN LANGER
04/10/2025
Special inspection requirement — Maintenance information
GLEN LANGER
04/10/2025
Special inspection requirement — HVAC-R and service water heating system controls
GLEN LANGER
04/10/2025
Special inspection requirement — Metering
GLEN LANGER
04/10/2025
Special inspection requirement — Permanent certificate
GLEN LANGER
03/19/2025
Permit issued — Plumbing
Q01121686-S1-PL
02/25/2025
Objection raised — Scope
02/19/2025
Objection resolved — Addressed
02/17/2025
Objection resolved — Addressed
02/17/2025
Objection resolved — Addressed
02/07/2025
Violation issued (ECB, open)
Construction
01/29/2025
Violation issued (ECB, open)
Construction
01/22/2025
Violation issued (ECB, open)
Construction
01/03/2025
Violation issued (ECB, open)
Construction
12/26/2024
Violation issued (ECB, open)
Construction
12/24/2024
Violation issued (ECB, open)
Construction
12/24/2024
Violation issued (ECB, open)
Unknown
12/24/2024
Violation issued (ECB, open)
Construction
12/09/2024
Permit issued — Plumbing
Q01121686-S1-PL
12/07/2024
Objection resolved — Addressed
12/07/2024
Objection resolved — Addressed
12/07/2024
Special inspection requirement — Electric vehicle service equipment requirements
11/23/2024
Special inspection requirement — Protection of exposed foundation insulation
11/21/2024
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
Latest 60 of 78 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedM & M PIPING AND HEATING09/10/2025
DOB NOWPlumbingPermit IssuedG.M.A. PLUMBING & HEATING03/19/2025
DOB NOWPlumbingPermit IssuedWASOFF PLBG & UTILITY CO12/09/2024
DOB NOWConstruction FencePermit IssuedR.N.K. ROMEO CONST INC09/25/2024
1 project · most recent 07/16/2026
FiledStatusContractorScope
07/16/2026———
1 project · most recent 07/16/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
07/16/2026Permit IssuedM & M PIPING AND HEATINGGas, Storm, Water/Sanitary
1 project · most recent 04/04/2025
General Wiring
FiledStatusContractorScope
04/04/2025Permit IssuedJD ELECTRICAL ENTERPRISESGeneral Wiring
▾Field Inspections (DOB CAP) — 11
DateTypeResultReport
07/08/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
06/01/2026Certified Water and Sanitary-WS-Fixtures-FinishCertifiedView ↗
05/04/2026Pass-Final PL - Up to 3 Requested FloorsPassView ↗
03/27/2026Pass-Final CND-Occupancy InspectionPassView ↗
01/07/2026Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/07/2026Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/02/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
10/02/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
10/02/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
10/02/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
10/02/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
07/15/2026Fire-Resistant Penetrations and Joints—special
07/15/2026Sprinkler Systems—special
04/11/2025HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
04/11/2025Maintenance informationGLEN LANGERenergy_progress
04/11/2025HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
04/11/2025MeteringGLEN LANGERenergy_progress
04/11/2025Energy Code Compliance InspectionsGLEN LANGERprogress
04/11/2025Fire-Resistant Penetrations and JointsGLEN LANGERspecial
04/11/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
04/11/2025HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
04/11/2025Permanent certificateGLEN LANGERenergy_progress
04/10/2025Fire-Resistant Penetrations and JointsGLEN LANGERspecial
04/10/2025Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationGLEN LANGERspecial
04/10/2025Energy Code Compliance InspectionsGLEN LANGERprogress
04/10/2025HVAC-R and service water piping design and insulationGLEN LANGERenergy_progress
04/10/2025HVAC-R and service water heating equipmentGLEN LANGERenergy_progress
04/10/2025Maintenance informationGLEN LANGERenergy_progress
04/10/2025HVAC-R and service water heating system controlsGLEN LANGERenergy_progress
04/10/2025MeteringGLEN LANGERenergy_progress
04/10/2025Permanent certificateGLEN LANGERenergy_progress
12/07/2024Electric vehicle service equipment requirements—energy_progress
11/23/2024Protection of exposed foundation insulation—energy_progress
11/07/2024Air barrier — testing —energy_progress
10/03/2024Insulation placement and R values—energy_progress
10/03/2024Fenestration air leakage—energy_progress
Latest 25 of 38.
▾Documents — 26 on file (BIS + DOB NOW)
▸Plans & Drawings5
▸DOB NOWPlans/Sketch5
08/21/2026Q01110545-I1Request digital key ↗
08/20/2026Q01121686-S2Request digital key ↗
08/20/2026Q01121686-P1Request digital key ↗
Showing 3 of 5 on file for this type
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026Q01121686-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026Q01121686-I1Open ↗
▸Seals & Professional Certifications11
▸DOB NOWDPL-1: Design Professional Seal & Signature5
08/20/2026Q01121686-S1Open ↗
08/20/2026Q01121686-S2Open ↗
08/20/2026Q01121686-P1Open ↗
Showing 3 of 5 on file for this type
▸DOB NOWProgress Inspector Seal & Signature4
09/23/2026Q01121686-P1Open ↗
09/23/2026Q01121686-P1Open ↗
08/27/2026Q01121686-S1Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature2
09/23/2026Q01121686-P1Open ↗
08/27/2026Q01121686-S1Open ↗
▸Safety & Tenant Protection1
▸DOB NOWParks Department Acknowledgment Letter for Street Trees Plan1
08/14/2026Q01121686-I1Open ↗
▸Environmental & Asbestos4
▸DOB NOWDEP ACP-5: Asbestos Assessment Report4
08/20/2026Q01121686-S2Open ↗
08/20/2026Q01121686-S1Open ↗
08/20/2026Q01121686-P1Open ↗
Showing 3 of 4 on file for this type
▸Other Documents3
▸DOB NOWSite Survey: Initial1
08/14/2026Q01121686-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/14/2026Q01121686-I1Open ↗
▸DOB NOWProperty Ownership Certification1
08/14/2026Q01121686-I1Open ↗