← Back
BuildNYC
Two family brick
137-21 KALMIA AVENUE
QUEENS · BIN 4624531
💬 Discuss this project
2023Year Built
—Stories
B1Building Class
R3-2Zoning
2,528 sfGross Floor Area
2Units
2 Active Violations ▸
Two family brick · Owner of record: 137 Kalmia Ave · 3,750 sf lot · 0.67 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalMechanicalPlumbingFire Protection
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Permit Issued — active, not yet Signed-off
RoofUnder Construction2p · 1 filing · 20 docs
AtticUnder Construction3p · 1 filing · 20 docs
Floor 3Under Construction17p · 1 filing · 20 docs
Floor 2Under Construction21p · 1 filing · 20 docs
Floor 1Under Construction20p · 1 filing · 20 docs
CellarUnder Construction20p · 1 filing · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
137 Kalmia Ave1910/04/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
11/04/2022$1.9M—Private party → 137 Kalmia Ave— not available
07/15/2022$1.8M—Private party → Private party— not available
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Bayside Associates1009/19/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LXC ConstructionGeneral Contractor507/08/2026
XH&RC Plumbing and HeatingPlumbing307/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
SD Testing & Inspection S7010709/19/2026
Building Lifecycle
10/28/2026
Objection raised — Other
10/28/2026
Objection resolved — Resolved
09/19/2026
Filed — New Building
HERE WITH TO FILE THE APPLICATION FOR PLUMBING AND SPRINKLER WORK IN CONJUNCTION WITH THE NEW BUILDING Q08036501. AS PER PLAN, NO CHANGE IN OCCUPANCY, USE, OR EGRESS.
Q08036501-P5
09/16/2026
Filed — New Building
HERE WITH TO FILE THE APPLICATION FOR PLUMBING AND SPRINKLER WORK IN CONJUNCTION WITH THE NEW BUILDING Q08036501. AS PER PLAN, NO CHANGE IN OCCUPANCY, USE, OR EGRESS.
Q08036501-P6
09/12/2026
Special inspection requirement — HVAC-R and service water heating system controls
XIUCHENG LI
81 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingPermit IssuedXH&RC Plumbing and Heating03/26/2026
DOB NOWGeneral ConstructionPermit IssuedLXC Construction03/02/2026
DOB NOWPlumbingPermit IssuedXH&RC Plumbing and Heating02/14/2025
DOB NOWGeneral ConstructionPermit IssuedLXC Construction02/12/2025
DOB NOWPlumbingPermit IssuedXH&RC Plumbing and Heating12/15/2023
DOB NOWGeneral ConstructionPermit IssuedLXC Construction08/24/2023
1 project · most recent 09/19/2026
Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScope
09/19/2026Permit IssuedLXC ConstructionHeating and Air Conditioning Systems, Heating Systems, Ventilation Systems
1 project · most recent 09/19/2026
Sprinkler System
FiledStatusContractorScope
09/19/2026——Sprinkler System
1 project · most recent 09/19/2026
Gas Plumbing-Sprinkler Storm Water/Sanitary
FiledStatusContractorScope
09/19/2026Permit IssuedXH&RC Plumbing and HeatingGas, Plumbing-Sprinkler, Storm, Water/Sanitary
1 project · most recent 10/06/2026
General Wiring
FiledStatusContractorScope
10/06/2026CompleteProject One ElectricGeneral Wiring
1 project · most recent 09/19/2026
Steel Masonry Wood
FiledStatusContractorScope
09/19/2026Permit IssuedXH&RC Plumbing and HeatingSteel, Masonry, Wood
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
09/01/2026Pass-Final CND-Occupancy InspectionPassView ↗
05/22/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
05/22/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
05/22/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
05/22/2024Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 79
DateRequirementInspectorRole
09/12/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
09/12/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
09/12/2026HVAC-R and service water heating system controlsXIUCHENG LIenergy_progress
09/12/2026HVAC-R and service water piping design and insulationXIUCHENG LIenergy_progress
09/12/2026HVAC-R and service water heating equipmentXIUCHENG LIenergy_progress
09/10/2026Wood – Seismic ResistanceXIUCHENG LIspecial
09/10/2026Energy Code Compliance InspectionsXIUCHENG LIprogress
09/10/2026Fire-Resistance Rated ConstructionXIUCHENG LIprogress
09/10/2026Interior lighting powerXIUCHENG LIenergy_progress
09/10/2026Permanent certificateXIUCHENG LIenergy_progress
09/10/2026Electric vehicle service equipment requirementsXIUCHENG LIenergy_progress
09/10/2026Air barrier — testing XIUCHENG LIenergy_progress
09/10/2026MeteringXIUCHENG LIenergy_progress
09/10/2026Insulation placement and R valuesXIUCHENG LIenergy_progress
09/10/2026Fenestration and door U-factor and product ratingsXIUCHENG LIenergy_progress
09/10/2026Maintenance informationXIUCHENG LIenergy_progress
09/10/2026Fenestration air leakageXIUCHENG LIenergy_progress
09/10/2026Air barrier - visual inspectionXIUCHENG LIenergy_progress
09/10/2026Fenestration areasXIUCHENG LIenergy_progress
09/10/2026Chimneys and ventsXIUCHENG LIspecial
09/10/2026Fire-Resistant Penetrations and JointsXIUCHENG LIspecial
09/10/2026MasonryXIUCHENG LIspecial
09/10/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, InstallationXIUCHENG LIspecial
09/10/2026Subgrade InspectionsXIUCHENG LIspecial
09/10/2026Concrete - Cast-In-PlaceXIUCHENG LIspecial
Latest 25 of 79.
60 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account