← Back
Two stories - detached, small or mid-size
137-41 SOUTHGATE STREET
QUEENS · Laurelton · BIN 4280269
💬 Discuss this project
1930Year Built
2Stories
A1Building Class
R2Zoning
1,100 sfGross Floor Area
1Units
Two stories - detached, small or mid-size · 5,000 sf lot · 0.22 FAR built · Flood zone X
Locations of Work
Electrical
Roof2p · 2 filings · 18 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TOM PETERSEN ARCHITECT, LLC207/21/2026
MOMENTUM SOLAR104/30/2024
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
KAMTECH RESTORATION CORP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
KAMTECH RESTORATION CORPGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
THOMAS PETERSEN ARCHITECT7854207/21/2026
MXV SIA LLC9281104/30/2024
Building Lifecycle
All (14)Filed (3)Permit Issued (2)Signed Off (1)Special Inspection (8)
08/27/2026
Signed off — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01364994-I1
07/21/2026
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01364994-P1
07/21/2026
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
07/21/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
07/21/2026
Special inspection requirement — Final
TOM PETERSEN
07/21/2026
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/04/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
TOM PETERSEN
05/04/2026
Special inspection requirement — Energy Code Compliance Inspections
TOM PETERSEN
05/04/2026
Special inspection requirement — Final
TOM PETERSEN
05/04/2026
Special inspection requirement — Air barrier - visual inspection
TOM PETERSEN
03/04/2026
Permit issued — Solar
Q01364994-I1-SL
02/26/2026
Filed — Alteration
ROOFTOP SOLAR INSTALLATION. NO CHANGE TO USE, OCCUPANCY OR EGRESS.
Q01364994-I1
05/13/2024
Permit issued — Solar
Q01041966-I1-SL
04/30/2024
Filed — Alteration
Q01041966-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offKAMTECH RESTORATION CORP03/04/2026
DOB NOWSolarSigned-offMOMENTUM SOLAR05/13/2024
2 projects · most recent 02/24/2026
FiledStatusContractorScope
02/24/2026CompleteBERGER QUALITY ELEC'L CON—
04/30/2024CompleteISLAND ELECTRIC CORP—
1 project · most recent 07/21/2026
FiledStatusContractorScope
07/21/2026Signed-offKAMTECH RESTORATION CORP9 panels, 4.1 kw, 590.47 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 8
DateRequirementInspectorRole
07/21/2026Air barrier - visual inspectionTOM PETERSENenergy_progress
07/21/2026Fire-Resistant Penetrations and JointsTOM PETERSENspecial
07/21/2026FinalTOM PETERSENprogress
07/21/2026Energy Code Compliance InspectionsTOM PETERSENprogress
05/04/2026Fire-Resistant Penetrations and JointsTOM PETERSENspecial
05/04/2026Energy Code Compliance InspectionsTOM PETERSENprogress
05/04/2026FinalTOM PETERSENprogress
05/04/2026Air barrier - visual inspectionTOM PETERSENenergy_progress
▾Documents — 18 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/22/2026Q01041966-I1Request digital key ↗
08/17/2026Q01364994-P1Request digital key ↗
08/17/2026Q01364994-I1Request digital key ↗
▸Seals & Professional Certifications11
▸DOB NOWProgress Inspector Seal & Signature6
08/31/2026Q01364994-I1Open ↗
08/31/2026Q01364994-I1Open ↗
08/31/2026Q01364994-I1Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/22/2026Q01041966-I1Open ↗
08/17/2026Q01364994-P1Open ↗
08/17/2026Q01364994-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/31/2026Q01364994-I1Open ↗
08/27/2026Q01364994-P1Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report3
08/22/2026Q01041966-I1Open ↗
08/17/2026Q01364994-P1Open ↗
08/17/2026Q01364994-I1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01041966-I1Open ↗