← Back
Two family converted from one family
137-59 BEDELL STREET
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R2Zoning
1,488 sfGross Floor Area
2Units
Two family converted from one family · 4,720 sf lot · 0.32 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalGeneral
Roof1p · 1 filing · 12 docs
Floor 21p · 1 filing · 12 docs
Floor 1
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
TRINITY SOLAR LLC207/22/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ACA ASSOCIATES203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
TRINITY SOLAR LLCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
IKRA CONSULTING LLC7032207/22/2025
Building Lifecycle
All (11)Filed (2)Permit Issued (1)Signed Off (1)Inspection (2)Special Inspection (5)
07/30/2025
Signed off — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01038469-I1
07/22/2025
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01038469-P1
07/21/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
MD MOSTAFA
07/21/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
MD MOSTAFA
07/21/2025
Special inspection requirement — Energy Code Compliance Inspections
Ayracon Almaraz
07/21/2025
Special inspection requirement — Final
Ayracon Almaraz
07/21/2025
Special inspection requirement — Air barrier - visual inspection
Ayracon Almaraz
01/06/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/10/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
05/31/2024
Permit issued — Solar
Q01038469-I1-SL
04/19/2024
Filed — Alteration
Installation of solar system on the roof as per plan. No change in use, egress or occupancy
Q01038469-I1
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarSigned-offTRINITY SOLAR LLC05/31/2024
1 project · most recent 04/12/2024
FiledStatusContractorScope
04/12/2024CompleteREDLINE ELECTRIC INC—
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
01/06/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/10/2024Fail-Final CND-Occupancy InspectionFailView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
07/21/2025Fire-Resistant Penetrations and JointsMD MOSTAFAspecial
07/21/2025Structural Stability – Alterations of existing buildingsMD MOSTAFAspecial
07/21/2025Energy Code Compliance InspectionsAyracon Almarazprogress
07/21/2025FinalAyracon Almarazprogress
07/21/2025Air barrier - visual inspectionAyracon Almarazenergy_progress
▾Documents — 12 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/19/2026Q01038469-I1Request digital key ↗
08/19/2026Q01038469-P1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWProgress Inspector Seal & Signature3
08/25/2026Q01038469-P1Open ↗
08/25/2026Q01038469-P1Open ↗
08/25/2026Q01038469-P1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q01038469-P1Open ↗
08/13/2026Q01038469-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026Q01038469-P1Open ↗
08/25/2026Q01038469-P1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q01038469-I1Open ↗
08/13/2026Q01038469-P1Open ↗
▸Approvals, Objections & Sign-offs1
▸DOB NOWUtility Company Final Acceptance Letter1
08/13/2026Q01038469-I1Open ↗