← Back
BuildNYC
Two family frame
137 BAY 31 STREET
BROOKLYN · BIN 3168050
💬 Discuss this project
1920Year Built
2Stories
B2Building Class
R5Zoning
2,720 sfGross Floor Area
2Units
0 Active ViolationsFDNY Report ↗
Two family frame · 2,223 sf lot · 1.22 FAR built · Flood zone X
Locations of Work
ArchitecturePlumbing
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
Floor 114p · 2 filings · 20 docs
Cellar13p · 2 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
Wang Long 86 Supermarket1107/08/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
10/13/2016$1.1M—Private party → Private party$404/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Chun Feng, Architect308/21/2025
Allen Shinfeld, P.E.312/23/2023
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JRK Creative603/21/2026
High Quality 338403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
American Standard P&H CororpPlumbing307/08/2026
High Quality ConstructionGeneral Contractor204/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Allen Shinfeld, P.E.1305209/27/2023
NKM Engineering6244102/24/2023
Building Lifecycle
12/03/2025
Signed off — Alteration
INTERIOR RENOVATION AT CELLAR AND 1ST FL FOR EXISTING 2 FAMILY, PARTITON WALL WORK AND PLUMBING WORKING WILL BE FILING SEPARATE APPLICATION .NO CHANGE IN MEANS OF USE,EGRESS OR OCCUPANCY.
B00828569-I1
11/03/2025
Signed off — Alteration
PLUMBING WORK ON EXIST. RESIDENTIAL HOUSE WITH, CAP/REMOVE/NEW GAS COMBINATION UNIT(HEAT & HW COIL), KITCHEN AND BATHROOM PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00834067-I1
09/18/2025
Permit renewed — Plumbing
Renewed without changes
B00834067-I1-PL
08/21/2025
Filed — Alteration
PLUMBING WORK ON EXIST. RESIDENTIAL HOUSE WITH, CAP/REMOVE/NEW GAS COMBINATION UNIT(HEAT & HW COIL), KITCHEN AND BATHROOM PLUMBING FIXTURES AS PER PLAN. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
B00834067-P2
01/24/2025
Special inspection requirement — Energy Code Compliance Inspections
Chun Feng
33 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp09/18/2025
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp04/11/2024
DOB NOWGeneral ConstructionSigned-offHigh Quality Construction04/11/2024
DOB NOWPlumbingSigned-offAmerican Standard P&H Cororp03/08/2023
DOB NOWGeneral ConstructionSigned-offHigh Quality Construction03/08/2023
2 projects · most recent 11/30/2023
General Wiring
FiledStatusContractorScope
11/30/2023CompleteKwong Ming Electric—
09/21/2023CompleteKwong Ming ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 3
DateTypeResultReport
01/04/2024Certified Gas-Gas-Piping-RoughingCertifiedView ↗
01/04/2024Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
01/04/2024Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
01/24/2025Energy Code Compliance InspectionsChun Fengprogress
01/24/2025HVAC-R and service water piping design and insulationChun Fengenergy_progress
01/24/2025HVAC-R and service water heating equipmentChun Fengenergy_progress
01/24/2025HVAC-R and service water heating system controlsChun Fengenergy_progress
12/12/2023HVAC-R and service water piping design and insulationALLEN SHINFELDenergy_progress
12/12/2023Energy Code Compliance InspectionsALLEN SHINFELDprogress
12/12/2023HVAC-R and service water heating system controlsALLEN SHINFELDenergy_progress
12/12/2023HVAC-R and service water heating equipmentALLEN SHINFELDenergy_progress
09/25/2023Fire-Resistant Penetrations and JointsALLEN SHINFELDspecial
09/25/2023Lighting in dwelling unitsALLEN SHINFELDenergy_progress
09/25/2023FinalALLEN SHINFELDprogress
09/25/2023Concrete - Cast-In-PlaceALLEN SHINFELDspecial
09/25/2023Energy Code Compliance InspectionsALLEN SHINFELDprogress
31 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account