ECB10/06/2026Failure to maintain elevator in building code compliant as per bc 3001.1 & 27-987. Upon an inspection 2 class 1 violations place the elevator in cease use. Emergency communication device is inoperative as per a$1K due
HPD07/30/2026§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE CONCRETE TILES IN THE 1st TERRACE FROM NORTH LOCATED AT APT 7B, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD07/30/2026§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT WEST WALL IN THE BATHROOM LOCATED AT APT 7B, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD07/30/2026HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF ROACHES IN THE ENTIRE APARTMENT LOCATED AT APT 7B, 7th STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD06/12/2026§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN AT WASH BASIN IN THE BATHROOM LOCATED AT APT 4W, 4th STORY, 3rd APARTMENT FROM EAST AT SOUTH
HPD06/10/2026§ 27-2026 ADM CODE REMOVE ALL OBSTRUCTIONS AND REPAIR ALL DEFECTS IN WASTE LINE AT SINK IN THE BATHROOM LOCATED AT APT 4W, 4th STORY, 3rd APARTMENT FROM NORTH AT EAST
ECB04/14/2026Class 1(cu):failure to maintain building in code compliant manner. Service elevator equipment as per BC3001.2 & 27-987. Upon inspection, alarm bell on elevator inoperative,repair.elevator phone inoperative,repa$1K due
HPD10/14/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7B, 7th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD10/13/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE LATCH SET AND ASSEMBLIES AT LAUNDRY ROOM DOOR AT PUBLIC HALL, 6th STORY
HPD10/12/2025§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD10/12/2025§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD10/12/2025§ 27-2005 ADM CODE PROPERLY SECURE THE LOOSE RADIATOR COVER AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD10/12/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE COLLAPSED WOOD WASHBASIN CABINET FLOOR IN THE 3rd BATHROOM FROM NORTH LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD10/12/2025§ 27-2005 HMC: REFIT DOOR AT WASH BASIN CABINET IN THE 3rd BATHROOM FROM NORTH LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD10/09/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... GREATER THAN 30 SQUARE FEET AT ALL WALLS AND CEILING IN THE BATHROOM LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD10/09/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELIN ENAMEL FINISH BY METHOD OF REGLAZING AT BATHTUB IN THE BATHROOM LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD10/09/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE MECHANICAL VENTILATION SYSTEM AT CEILING IN THE BATHROOM LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD10/09/2025§ 27-2045(B)(1)(B) HMC, § 12-06, § 12-07, § 12-09 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD10/09/2025§ 27-2045(B)(1)(A) HMC, § 12-01, § 12-03 RCNY REPAIR, REPLACE OR PROVIDE AN APPROVED AND OPERATIONAL SMOKE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH DEPARTMENT OF BUILDINGS RULES AND REGULATIONS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD10/09/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE WASH BASIN VANITY CABINET IN THE BATHROOM LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD10/09/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASEBOARD HEATER COVER AT NORTH WALL IN THE 1st ROOM FROM EAST LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM WEST AT NORTH , SECTION AT WEST
HPD08/02/2025HMC ADM CODE: § 27-2017.4 ABATE THE INFESTATION CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 7B, 3rd STORY, 2nd APARTMENT FROM WEST AT NORTH
HPD04/15/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE WARPING AND LIFTING HARD WOOD FLOOR AT WALKING AREA IN THE PRIVATE HALLWAY LOCATED AT APT 3Q, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
HPD04/15/2025§ 27-2005 ADM CODE REPAIR THE BROKEN OR DEFECTIVE PLASTERED SURFACES AND PAINT IN A UNIFORM COLOR AT CEILING IN THE BATHROOM LOCATED AT APT 3Q, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
HPD04/15/2025§ 27-2026, 2027 HMC: PROPERLY REPAIR THE SOURCE AND ABATE THE EVIDENCE OF A WATER LEAK AT CEILING IN THE BATHROOM LOCATED AT APT 3Q, 3rd STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION ''NORTH''
ECB04/08/2025Failure to submit an acceptable required cycle 9C report of critical examination documenting condition of exterior wall and appurtenances required by 28-302.4 for control #914906. Remedy: submit acceptable requ$10K due
HPD02/10/2025§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... LESS THAN 10SQFT AT SOUTH WALL AND NORTH WALL IN THE BATHROOM LOCATED AT APT 6J, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH ORIGINAL VIOLATION 17686005 ISSUED 10-FEB-25 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD02/10/2025§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE PORCELAIN ENNAMEL FINISH BY METHOD OF REGLAZING IN THE BATHROOM LOCATED AT APT 6J, 7th STORY, 3rd APARTMENT FROM SOUTH AT WEST , SECTION AT SOUTH
HPD01/09/2025§ 27-2005 HMC: PROPERLY REPAIR OR REPLACE THE BROKEN OR DEFECTIVE BASEBOARD RADIATOR AT WEST WALL IN THE 1st ROOM FROM NORTH LOCATED AT APT 1G, 1st STORY, 1st APARTMENT FROM SOUTH AT WEST
HPD12/04/2024§ 27-2005 ADM CODE PROPERLY REPAIR WITH SIMILAR MATERIAL THE BROKEN OR DEFECTIVE VINYL FLOOR TILES IN THE 3rd ROOM FROM EAST LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST
HPD12/04/2024§ 27-2017.3 HMC: TRACE AND REPAIR THE SOURCE AND ABATE THE VISIBLE MOLD CONDITION... AT SOUTH AND NORTH WALL IN THE BATHROOM LOCATED AT APT 6J, 6th STORY, 2nd APARTMENT FROM SOUTH AT WEST ORIGINAL VIOLATION 17510224 ISSUED 04-DEC-24 HAS BEEN UPGRADED TO CLASS B PER ADMINISTRATIVE CODE §27-2017.3a(3)(a) or (b).
HPD11/01/2024Hmc ADM code: § 27-2017.4 abate the infestation consisting of rodents evidence of rodents found. At garage
HPD11/01/2024Hmc ADM code: § 27-2017.4 abate the infestation consisting of mice at garage
DOB02/22/2024Failed to file FISP cycle 9C technical report by 2/21/2024
ECB09/12/201752M07,61T07,68B07,100B07,59U15-52)hoist data tag missing 61)machine disconnect switch unlabel, provide maint company. 68)maintenance log insufficient. 59)machine brake tag/expiredNothing owed — awaiting certificate of correction
Likely answered · the city's own records show a filing, but DOB's feed still lists these as active
DOB06/20/2023Violation issued-failure to file 2018 external low pressure inspectionThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered4 identical filings
DOB04/06/2018Violation issued for failure to file annual boiler 2016 inspection reportThe owner has filed since: boiler inspection reports are on file for later years (latest 2026). This one is not shown as answered4 identical filings