← Back
One story retail building
1385 SUTTER AVENUE
BROOKLYN · BIN 3095583
💬 Discuss this project
1977Year Built
1.5Stories
K1Building Class
R6AZoning
1,760 sfGross Floor Area
1Units
6 Open Violations 3 unresolved · 3 paperwork only ▸FDNY Report ↗
One story retail building · Owner of record: ALMONTE LINCOLN LLC · 3,600 sf lot · 0.49 FAR built · Flood zone X
Locations of Work
StructuralElectricalMechanicalPlumbingFire ProtectionGeneral
Roof8p · 2 filings · 20 docs
Bulkhead3p · 1 filing · 20 docs
Floor 92p · 1 filing · 20 docs
Floor 81p · 1 filing · 20 docs
Floor 74p · 1 filing · 20 docs
Floor 61p · 1 filing · 20 docs
Floor 51p · 1 filing · 20 docs
Floor 41p · 1 filing · 20 docs
Floor 31p · 1 filing · 20 docs
Floor 24p · 1 filing · 20 docs
Floor 13p · 1 filing · 20 docs
Mezzanine2p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LEAD IT BUILDERS209/08/2026
OWNER OF 1385 SUTTER AVEN103/22/2026
MILLER TOBACCO CO203/22/2026
1385 SUTTER803/21/2026
CENTER ONE REALTY603/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
ADROIT ENGINEERING PLLC208/04/2026
ELEVATED ENGINEERING NYC301/26/2026
VASILIOS ARTEMIOU PE401/13/2026
NIKOLAI KATZ ARCHITECT212/18/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
EXPRESS FILING INC1803/21/2026
Building Lifecycle
All (64)Filed (11)Violation (7)Objection (16)Special Inspection (30)
08/04/2026
Filed — Full Demolition
Full demolition to a one story building
B01407672-S1
07/29/2026
Objection resolved — Addressed
07/22/2026
Objection raised — Other
07/06/2026
Filed — Full Demolition
Full demolition to a one story building
B01407672-I1
03/10/2026
Objection resolved — Addressed
03/05/2026
Objection resolved — Addressed
02/25/2026
Objection resolved — Addressed
02/19/2026
Objection raised — Other
02/19/2026
Objection raised — Other
02/09/2026
Objection raised — Other
02/05/2026
Objection resolved — Addressed
01/27/2026
Objection resolved — Addressed
01/26/2026
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S1
01/20/2026
Objection raised — Other
01/13/2026
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S7
01/13/2026
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S9
01/06/2026
Objection raised — Other
01/06/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/06/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
01/06/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
01/06/2026
Special inspection requirement — HVAC-R and service water heating system controls
01/06/2026
Special inspection requirement — HVAC-R and service water heating equipment
01/06/2026
Special inspection requirement — Maintenance information
01/02/2026
Objection raised — Other
01/02/2026
Objection raised — Other
01/02/2026
Objection raised — Energy
12/30/2025
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S6
12/30/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
12/30/2025
Special inspection requirement — Post-installed Anchors
12/30/2025
Special inspection requirement — Standpipe Systems
12/18/2025
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S4
12/18/2025
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S5
12/18/2025
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S2
12/18/2025
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-S3
12/11/2025
Objection raised — Other
12/08/2025
Special inspection requirement — Concrete - Cast-In-Place
12/08/2025
Special inspection requirement — Subgrade Inspections
12/08/2025
Special inspection requirement — Subsurface Investigations (Borings/Test Pits)
12/05/2025
Special inspection requirement — Final
12/05/2025
Special inspection requirement — Footing and Foundation
11/04/2025
Filed — New Building
SOE SPECIFICATIONS FILED IN CONJUNCTION WITH NB APPLICATION # B01297948-I1
B01297948-I1
10/05/2025
Special inspection requirement — Protection of exposed foundation insulation
10/05/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
10/05/2025
Special inspection requirement — Interior lighting power
10/05/2025
Special inspection requirement — Lighting controls
10/05/2025
Special inspection requirement — Energy Code Compliance Inspections
10/05/2025
Special inspection requirement — Fire-Resistance Rated Construction
10/05/2025
Special inspection requirement — Air barrier — testing
10/05/2025
Special inspection requirement — Exterior lighting power
10/05/2025
Special inspection requirement — Air barrier - visual inspection
10/05/2025
Special inspection requirement — Fenestration air leakage
10/05/2025
Special inspection requirement — Fenestration areas
10/05/2025
Special inspection requirement — Electrical motors and elevators
10/05/2025
Special inspection requirement — Fenestration and door U-factor and product ratings
10/05/2025
Special inspection requirement — Insulation placement and R values
10/05/2025
Special inspection requirement — Lighting in dwelling units
10/05/2025
Special inspection requirement — Metering
02/07/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/07/2001
Violation issued (DOB, open)
V-DOB VIOLATION - ACTIVE
02/07/2001
Violation issued (ECB, open)
Construction
Latest 60 of 64 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISFBISSUEDSTAR INDUSTRIAL SERVICE07/31/2018
1 project · most recent 01/26/2026
Heating and Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
01/26/2026——Heating and Air Conditioning Systems
Heat / Cool
Amana PTH073J35 7,000 BTU · Ptac ×52
PTH153J35 14,400 BTU · Ptac ×42
PTH093J35 9,000 BTU · Ptac ×31
PTH123J35 11,600 BTU · Ptac ×9
1 project · most recent 01/26/2026
Sprinkler System
FiledStatusContractorScope
01/26/2026——Sprinkler System
1 project · most recent 01/26/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
01/26/2026——Gas, Storm, Water/Sanitary
2 projects · most recent 11/26/2025
General Wiring
FiledStatusContractorScope
11/26/2025Permit IssuedPOWER DIRECT ELECTRIC INCGeneral Wiring
11/26/2025Permit IssuedPOWER DIRECT ELECTRIC INC—
1 project · most recent 01/26/2026
Concrete Masonry
FiledStatusContractorScope
01/26/2026——Concrete, Masonry
1 project · most recent 01/26/2026
Fence
FiledStatusContractorScope
01/26/2026——Fence
▾Special Inspection Requirements (DOB NOW) — 31
DateRequirementInspectorRole
01/06/2026Fire-Resistant Penetrations and Joints—special
01/06/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
01/06/2026HVAC-R and service water piping design and insulation—energy_progress
01/06/2026HVAC-R and service water heating system controls—energy_progress
01/06/2026HVAC-R and service water heating equipment—energy_progress
01/06/2026Maintenance information—energy_progress
12/30/2025Fire-Resistant Penetrations and Joints—special
12/30/2025Post-installed Anchors—special
12/30/2025Standpipe Systems—special
12/08/2025Concrete - Cast-In-Place—special
12/08/2025Subgrade Inspections—special
12/08/2025Subsurface Investigations (Borings/Test Pits)—special
12/05/2025Final—progress
12/05/2025Footing and Foundation—progress
10/05/2025Protection of exposed foundation insulation—energy_progress
10/05/2025Fire-Resistant Penetrations and Joints—special
10/05/2025Interior lighting power—energy_progress
10/05/2025Lighting controls—energy_progress
10/05/2025Energy Code Compliance Inspections—progress
10/05/2025Fire-Resistance Rated Construction—progress
10/05/2025Air barrier — testing —energy_progress
10/05/2025Exterior lighting power—energy_progress
10/05/2025Air barrier - visual inspection—energy_progress
10/05/2025Fenestration air leakage—energy_progress
10/05/2025Fenestration areas—energy_progress
Latest 25 of 31.
▾Documents — 52 on file (BIS + DOB NOW)
▸Plans & Drawings11
▸DOB NOWPlans/Sketch11
08/19/2026B01297948-S6Request digital key ↗
08/16/2026B01407672-S1Request digital key ↗
08/15/2026B01407672-I1Request digital key ↗
Showing 3 of 11 on file for this type
▸Applications & Permits6
▸BISPLAN / WORK APPROVAL APPLICATION3
02/20/2026340923530Open ↗
02/19/2026340923530Open ↗
07/30/2018340622570Open ↗
▸BISWORK PERMIT APPLICATION2
07/30/2018340622570Open ↗
07/30/2018340622570Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
02/19/2026340923530Open ↗
▸Zoning, Tax Lot & Property Records2
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/14/2026B01297948-I1Open ↗
▸DOB NOWZD1: DOB Zoning Diagram1
08/14/2026B01297948-I1Open ↗
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature11
08/19/2026B01297948-S6Open ↗
08/19/2026B01297948-S7Open ↗
08/19/2026B01297948-S9Open ↗
Showing 3 of 11 on file for this type
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY2
02/19/2026340923530Open ↗
07/30/2018340622570Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
07/30/2018340622570Open ↗
▸BISAPPLICANT OWNER SIGNATURE1
02/19/2026340923530Open ↗
▸BISREQUIRED ITEMS CHECKLIST FOR PROFESSIONAL CERTIFICATION1
07/30/2018340622570Open ↗
▸Trade Schedules & Equipment1
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT1
07/30/2018340622570Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
02/19/2026340923530Open ↗
▸DOB NOWStreet Tree Checklist1
08/14/2026B01297948-I1Open ↗
▸Environmental & Asbestos1
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
07/30/2018340622570Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY1
07/30/2018340622570Open ↗
▸BISNYCECC ANALYSIS1
07/30/2018340622570Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
07/30/2018340622570Open ↗
▸Inspections & Test Reports1
▸BISTECHNICAL REPORT: RESPONSIBILITY1
07/30/2018340622570Open ↗
▸Cost, Insurance & Ownership1
▸BISCOST AFFIDAVIT1
07/30/2018340622570Open ↗
▸Filing & Intake Forms3
▸BISEFILING JOB APPLICATION COVER SHEET2
02/19/2026340923530Open ↗
07/30/2018340622570Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
02/19/2026340923530Open ↗
▸Other Documents5
▸DOB NOWProperty Ownership Certification2
08/15/2026B01407672-I1Open ↗
08/14/2026B01297948-I1Open ↗
▸DOB NOWStructure Photographs1
08/15/2026B01407672-I1Open ↗
▸DOB NOWSite Survey: Initial1
08/14/2026B01297948-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1