← Back
Car sales or rental lots without showroom
Hong Ye Condominium
139-04 HILLSIDE AVENUE · Jamaica Hills-Briarwood · BIN 4206957
💬 Discuss this project
2008Year Built
—Stories
GUBuilding Class
C4-4DZoning
500 sfGross Floor Area
1Units
3 Open Violations ▸FDNY Report ↗
Car sales or rental lots without showroom · Owner of record: SWEET PROSPECT REALTY LLC · 6,525 sf lot · 0.08 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralElectricalMechanicalPlumbingFire ProtectionEquipmentLandscapeCivilGeneral
Site & exterior2p · 1 filing · 4 docs
Filed — no permit issued234p · 4 filings · 20 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
SWEET PROSPECT REALTY3303/22/2026
HONG YE CONDO909/13/2026
HPD103/21/2026
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
08/02/2016$2.1M—HILLSIDE FLOORS, INC. → SWEET PROSPECT REALTY LLC$4,179/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
CNY ENGINEERING P.C503/19/2026
Z & T ENGINEERING, P.C.601/09/2026
MICHAEL KANG ARCHITECT P.C.502/21/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
MICHAEL KANG ARCHITECT P C1203/21/2026
CNY ENGINEERING PC603/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
ROCK CONSTRUCTION ENTERPRGeneral Contractor403/21/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Z & T ENGINEERING, P.C.591305/19/2022
Building Lifecycle
All (97)Filed (16)Permit Issued (1)Violation (9)Objection (41)Special Inspection (30)
07/29/2026
Violation issued (ECB, open)
Construction
07/29/2026
Violation issued (ECB, open)
Construction
07/29/2026
Violation issued (ECB, open)
Construction
05/05/2026
Special inspection requirement — Final
05/05/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
05/05/2026
Special inspection requirement — Fire-Resistance Rated Construction
05/05/2026
Special inspection requirement — HVAC-R and service water heating equipment
05/05/2026
Special inspection requirement — Energy Code Compliance Inspections
05/05/2026
Special inspection requirement — Shutoff dampers
05/05/2026
Special inspection requirement — HVAC-R and service water heating system controls
05/05/2026
Special inspection requirement — Maintenance information
05/05/2026
Special inspection requirement — Mechanical Systems
05/05/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
04/20/2026
Objection resolved — Resolved
04/01/2026
Objection raised — Other
03/26/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
03/26/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/26/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/26/2026
Special inspection requirement — Energy Code Compliance Inspections
03/26/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/26/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/26/2026
Special inspection requirement — Sprinkler Systems
03/25/2026
Objection resolved — Addressed
03/24/2026
Objection raised — Admin
03/19/2026
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-P3
03/19/2026
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-P1
03/12/2026
Special inspection requirement — HVAC-R and service water heating equipment
03/12/2026
Special inspection requirement — HVAC-R and service water piping design and insulation
03/12/2026
Special inspection requirement — Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation
03/12/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
03/12/2026
Special inspection requirement — Sprinkler Systems
03/12/2026
Special inspection requirement — Energy Code Compliance Inspections
03/12/2026
Special inspection requirement — HVAC-R and service water heating system controls
03/10/2026
Special inspection requirement — Maintenance information
03/10/2026
Special inspection requirement — Air barrier — testing
03/10/2026
Special inspection requirement — Exterior lighting power
03/10/2026
Special inspection requirement — Vestibules
03/10/2026
Special inspection requirement — Protection of exposed foundation insulation
03/10/2026
Special inspection requirement — Fire-Resistance Rated Construction
02/04/2026
Objection raised — Admin
01/26/2026
Objection raised — Admin
01/21/2026
Objection raised — Other
01/21/2026
Objection raised — Other
01/21/2026
Objection raised — Other
01/21/2026
Objection raised — Other
01/21/2026
Objection raised — Other
01/21/2026
Objection raised — Other
01/21/2026
Objection raised — Other
01/09/2026
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-S7
01/09/2026
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-S6
01/09/2026
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-S5
02/21/2025
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-P2
06/20/2023
Objection raised — Energy
06/20/2023
Objection resolved — Addressed
04/27/2023
Filed — New Building
INSTALLATION OF CONCRETE COLUMNS,CONCRETE WALLS, CONCRETE BEAMS ANDTWO-WAY CONCRETE SLABS FOR A NEW 7STORY MIXED-USE BUILDING
Q00582096-S3
10/19/2022
Objection resolved — Addressed
10/03/2022
Filed — Alteration
Q08014344-I1
09/29/2022
Objection raised — Inspections
09/27/2022
Filed — Alteration
install 311' long construction fence, include the boundary between adjacent property.
Q00666472-P1
09/01/2022
Permit issued — Construction Fence
Q00666472-I1-FN
Latest 60 of 97 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWConstruction FencePermit IssuedROCK CONSTRUCTION ENTERPR09/01/2022
BISPLISSUEDL.RICHARDS PLBG & HTG08/21/2002
BIS—ISSUEDR DESIGN HOMEBUILDERS INC03/08/2002
BISEQISSUEDR DESIGN HOMEBUILDERS, INC03/08/2002
BIS—ISSUEDN.B.I EQUIPMENT CORP08/30/2000
BISEQISSUEDN.B.I EQUIPMENT CORP.08/30/2000
BISEQISSUEDN/A09/26/1995
BISOTISSUEDN/A09/26/1995
BISOTISSUEDN/A02/22/1994
BISEQISSUEDN/A02/22/1994
1 project · most recent 03/19/2026
Air Conditioning Systems Heating and Air Conditioning Systems Heating Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
03/19/2026——Air Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems
Cooling
Amana PTC073G 7,000 BTU · Ptac ×18
PTC093G 9,200 BTU · Ptac ×17
PTC123G 11,900 BTU · Ptac ×17
PTC153G 14,800 BTU · Ptac ×5
Carrier 48HCDA06H 60,000 BTU · Rooftop Unit ×1
Mitsubishi Electric PUHY-P144TNU-A 144,000 BTU · Vrf Outdoor ×1
Heat / Cool
Mitsubishi Electric MXZ-2C20NA3 18,000 BTU · Condensing Unit ×30
MXZ-3C30NA3 28,400 BTU · Condensing Unit ×24
MXZ-3C24NA3 22,000 BTU · Condensing Unit ×12
PUHY-EP168TNU-A-TH(-BS) 168,000 BTU · Vrf Outdoor ×4
PUHY-EP72TNU 72,000 BTU · Vrf Outdoor ×2
Daikin DPS-003-AHHE2 36,000 BTU · Rooftop Unit ×2
Heating
Amana PTC073G 7,000 BTU · Ptac ×18
PTC093G 9,000 BTU · Ptac ×17
PTC123G 11,700 BTU · Ptac ×17
PTC153G 14,500 BTU · Ptac ×5
Weil-Mclain CGA-25 38,000 BTU · Boiler ×19
Modine PDP400 400,000 BTU ×6
Carrier 48FCDA06H 53,000 BTU · Rooftop Unit ×1
Mitsubishi Electric PUHY-P144TNU-A 160,000 BTU · Vrf Outdoor ×1
Ventilation
Greenheck G-080-VG 379 CFM · Exhaust Fan ×28
G-090-VG 515 CFM · Exhaust Fan ×3
Mitsubishi Electric LGH-F300RVX2-E 300 CFM · Erv ×16
LGH-F940RVX2-E 940 CFM · Erv ×4
LGH-F1200RVX-E 1,200 CFM · Erv ×1
LGH-F600RVX2-E 600 CFM · Erv ×2
Fantech FR 100 100 CFM · Exhaust Fan ×2
1 project · most recent 03/19/2026
Sprinkler System
FiledStatusContractorScope
03/19/2026——Sprinkler System
1 project · most recent 03/19/2026
Gas Storm Water/Sanitary
FiledStatusContractorScope
03/19/2026——Gas, Storm, Water/Sanitary
2 projects · most recent 03/19/2026
Concrete
FiledStatusContractorScope
03/19/2026——Concrete
05/19/2022——1 scope_items
1 project · most recent 09/27/2022
Fence
FiledStatusContractorScope
09/27/2022Permit IssuedROCK CONSTRUCTION ENTERPRFence
▾Special Inspection Requirements (DOB NOW) — 84
DateRequirementInspectorRole
05/05/2026Energy Code Compliance Inspections—progress
05/05/2026Mechanical Systems—special
05/05/2026Maintenance information—energy_progress
05/05/2026HVAC-R and service water piping design and insulation—energy_progress
05/05/2026HVAC-R and service water heating equipment—energy_progress
05/05/2026Shutoff dampers—energy_progress
05/05/2026HVAC-R and service water heating system controls—energy_progress
05/05/2026Final—progress
05/05/2026Fire-Resistance Rated Construction—progress
05/05/2026Fire-Resistant Penetrations and Joints—special
03/26/2026Fire-Resistant Penetrations and Joints—special
03/26/2026HVAC-R and service water piping design and insulation—energy_progress
03/26/2026HVAC-R and service water heating system controls—energy_progress
03/26/2026HVAC-R and service water heating equipment—energy_progress
03/26/2026Energy Code Compliance Inspections—progress
03/26/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
03/26/2026Sprinkler Systems—special
03/12/2026HVAC-R and service water piping design and insulation—energy_progress
03/12/2026HVAC-R and service water heating equipment—energy_progress
03/12/2026Private On-Site Storm Water Disposal Systems-, and Detention Facilities, Installation—special
03/12/2026HVAC-R and service water heating system controls—energy_progress
03/12/2026Energy Code Compliance Inspections—progress
03/12/2026Sprinkler Systems—special
03/12/2026Fire-Resistant Penetrations and Joints—special
03/10/2026Metering—energy_progress
Latest 25 of 84.
▾Documents — 75 on file (BIS + DOB NOW)
▸Plans & Drawings16
▸DOB NOWPlans/Sketch16
08/26/2026Q00728447-I1Request digital key ↗
08/26/2026Q00728447-S1Request digital key ↗
08/26/2026Q00728314-I1Request digital key ↗
Showing 3 of 16 on file for this type
▸Applications & Permits4
▸BISPLAN / WORK APPROVAL APPLICATION3
10/07/2022440748657Open ↗
05/12/2017421463455Open ↗
05/12/2017421463455Open ↗
▸BISBPP-5 - Authorization to the Department of Transportation1
10/07/2022440748657Open ↗
▸Zoning, Tax Lot & Property Records11
▸DOB NOWRestrictive Declaration/Easement 19
08/17/2026Q00582096-P1Open ↗
08/17/2026Q00582096-S2Open ↗
08/17/2026Q00582096-S1Open ↗
Showing 3 of 9 on file for this type
▸DOB NOWZD1: DOB Zoning Diagram2
08/17/2026Q00582096-I1Open ↗
08/13/2026Q00582096-P2Open ↗
▸Seals & Professional Certifications21
▸DOB NOWDPL-1: Design Professional Seal & Signature16
08/25/2026Q00666472-I1Open ↗
08/25/2026Q08014344-I1Open ↗
08/17/2026Q00582096-I1Open ↗
Showing 3 of 16 on file for this type
▸BISAPPLICANT OWNER SIGNATURE1
10/07/2022440748657Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
10/07/2022440748657Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION1
05/12/2017421463455Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q00728314-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature1
09/01/2026Q00728314-I1Open ↗
▸Trade Schedules & Equipment2
▸DOB NOWDEP: Sewer Certification (Sanitary/Storm)2
08/17/2026Q00582096-I1Open ↗
08/13/2026Q00582096-P2Open ↗
▸Safety & Tenant Protection3
▸DOB NOWStreet Tree Checklist2
08/17/2026Q00582096-I1Open ↗
08/13/2026Q00582096-P2Open ↗
▸BISBPP: STREET TREES SITE PLAN1
10/07/2022440748657Open ↗
▸Environmental & Asbestos6
▸DOB NOWOER: Notice to Proceed5
08/17/2026Q00582096-P3Open ↗
08/17/2026Q00582096-S2Open ↗
08/17/2026Q00582096-I1Open ↗
Showing 3 of 5 on file for this type
▸BISENVIRONMENTAL RESTRICTIONS - OER NOTICE TO PROCEED1
10/07/2022440748657Open ↗
▸Filing & Intake Forms4
▸BISEFILING COVER SHEET2
05/12/2017421463455Open ↗
05/12/2017421463455Open ↗
▸BISBPP: CHECKLIST IN LIEU OF PLANS-ALT31
10/07/2022440748657Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
10/07/2022440748657Open ↗
▸Other Documents8
▸DOB NOWProperty Ownership Certification2
08/17/2026Q00582096-I1Open ↗
08/13/2026Q00582096-P2Open ↗
▸DOB NOWSite Survey: Initial2
08/17/2026Q00582096-I1Open ↗
08/13/2026Q00582096-P2Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone2
08/17/2026Q00582096-I1Open ↗
08/13/2026Q00582096-P2Open ↗
▸BISRECORDS MGMT FEE PAYMENT RECEIPT1
10/07/2022440748657Open ↗
▸BISBPP - SUPPORTING DOCUMENTATION1
10/07/2022440748657Open ↗