← Back
Primarily 1 family with 1 store or office
139-12 73 TERRACE
QUEENS · Kew Gardens Hills · BIN 4142878
💬 Discuss this project
1950Year Built
2.5Stories
S1Building Class
R2XZoning
—Gross Floor Area
2Units
1 Open Violation 0 unresolved · 1 paperwork only ▸FDNY Report ↗
Primarily 1 family with 1 store or office · 0.82 FAR built · Flood zone X
Locations of Work
ArchitectureMechanicalGeneral
Filed — no permit issued4p · 1 filing · 3 docs
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD C. HICKS RA105/05/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
ABRIS DESIGN STUDIO103/21/2026
Building Lifecycle
All (39)Filed (1)Violation (11)Objection (24)Special Inspection (3)
05/18/2021
Objection raised — Scope
05/18/2021
Objection raised — Scope
05/18/2021
Objection raised — Zoning
05/18/2021
Objection resolved — Resolved
05/18/2021
Objection raised — Zoning
05/18/2021
Objection raised — Scope
05/18/2021
Objection resolved — Resolved
05/18/2021
Objection raised — Other
05/18/2021
Objection raised — Fire_Protection
05/18/2021
Objection resolved — Addressed
05/18/2021
Objection raised — Zoning
05/18/2021
Objection resolved — Resolved
05/18/2021
Objection raised — Zoning
05/18/2021
Objection resolved — Resolved
05/18/2021
Objection raised — Zoning
05/18/2021
Objection resolved — Resolved
05/18/2021
Objection raised — Zoning
05/18/2021
Objection raised — Admin
05/18/2021
Objection raised — Fire_Protection
05/18/2021
Objection resolved — Addressed
05/18/2021
Objection raised — Scope
05/18/2021
Objection resolved — Addressed
05/18/2021
Objection raised — Scope
05/18/2021
Objection resolved — Addressed
05/05/2021
Filed — Alteration
INTERIOR RENOVATION TO CLOSE EXISTING 2nd FLOOR OPEN TO BELOW AREA AT REAR AND ARRANGEMENT OF HOME OCCUPATION PROFESSIONAL OFFICE
Q00514619-I1
05/05/2021
Special inspection requirement — Fire-Resistant Penetrations and Joints
05/05/2021
Special inspection requirement — Energy Code Compliance Inspections
05/05/2021
Special inspection requirement — Interior lighting power
03/01/2021
Violation issued (ECB, open)
Construction
03/01/2021
Violation issued (ECB, closed)
Zoning
06/11/1997
Violation issued (ECB, closed)
Plumbing
11/14/1995
Violation issued (DOB, closed)
VPW*-VIOLATION UNSERVED ECB-WORK WITHOUT PERMIT-DISMISSED
11/13/1995
Violation issued (ECB, closed)
Construction
11/13/1995
Violation issued (ECB, closed)
Site Safety
11/13/1995
Violation issued (ECB, closed)
Site Safety
11/13/1995
Violation issued (ECB, closed)
Site Safety
11/13/1995
Violation issued (ECB, closed)
Site Safety
11/13/1995
Violation issued (ECB, closed)
Site Safety
11/13/1995
Violation issued (ECB, closed)
Site Safety
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDSEA BRIGHT SOLAR LLC09/29/2022
BISPLISSUEDSCARPONI&SON PLBG&HTG COR03/25/1996
BIS—ISSUEDNEW LINE GENERAL CONTRACTING INC11/13/1995
1 project · most recent 11/29/2022
FiledStatusContractorScope
11/29/2022CompleteAMBER ELECTL CONTNG INC—
▾Special Inspection Requirements (DOB NOW) — 3
DateRequirementInspectorRole
05/05/2021Fire-Resistant Penetrations and Joints—special
05/05/2021Energy Code Compliance Inspections—progress
05/05/2021Interior lighting power—energy_progress
▾Documents — 25 on file (BIS + DOB NOW)
▸Plans & Drawings1
▸DOB NOWPlans/Sketch1
08/15/2026Q00514619-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
09/24/2022440746837Open ↗
▸BISWORK PERMIT APPLICATION1
09/29/2022440746837Open ↗
▸Seals & Professional Certifications3
▸BISAPPLICANT OWNER SIGNATURE1
09/24/2022440746837Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY1
09/24/2022440746837Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature1
08/27/2026Q00514619-I1Open ↗
▸Safety & Tenant Protection1
▸BISTPP1: TENANT PROTECTION PLAN1
09/29/2022440746837Open ↗
▸Environmental & Asbestos2
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
09/24/2022440746837Open ↗
▸DOB NOWDEP ACP-5: Asbestos Assessment Report1
08/15/2026Q00514619-I1Open ↗
▸Energy Compliance7
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY3
12/28/2022440746837Open ↗
09/29/2022440746837Open ↗
09/24/2022440746837Open ↗
▸BISTECHNICAL REPORT STATEMENT OF RESPONSIBILITY FOR ENERGY CODE PROGRESS INSPECTIONS1
09/24/2022440746837Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (PRELIMINARY)1
09/24/2022440746837Open ↗
▸BISPTA4: SOLAR TAX ABATEMENT APPLICATION (FINAL)1
12/28/2022440746837Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
12/28/2022440746837Open ↗
▸Inspections & Test Reports3
▸BISTECHNICAL REPORT: RESPONSIBILITY3
12/28/2022440746837Open ↗
09/29/2022440746837Open ↗
09/24/2022440746837Open ↗
▸Approvals, Objections & Sign-offs1
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
12/29/2022440746837Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
12/28/2022440746837Open ↗
09/24/2022440746837Open ↗
▸Filing & Intake Forms2
▸BISADDITIONAL INFORMATION1
09/24/2022440746837Open ↗
▸BISEFILING JOB APPLICATION COVER SHEET1
09/24/2022440746837Open ↗
▸Other Documents1
▸BISTax Abatement Miscellaneous1
12/29/2022440746837Open ↗