04/10/2025
Signed off — Alteration
JOB TO RESTORE A DETACHED GARAGE TO THE PRIOR HEIGHT LEGAL CONDITION AND LEGALIZE EXISTING SIDE EXTENSION, TO CURE VIOLATION 35441817X. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00688184-I1
04/01/2025
Inspection — Pass-Final General Construction Non-Directive 14
Pass
View inspection ↗
03/18/2025
Signed off — Alteration
PLUMBING WORK TO REMOVE BATHROOM PLUMBING FIXTURES (SINK AND LAVATORY) IN CONJUNCTION WITH GCJOB# Q00688184, TO REMOVE VIOLATION # 35441817X
Q00692512-I1
12/27/2024
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
10/01/2024
Permit issued — Plumbing
Q00692512-I1-PL
03/29/2024
Permit issued — General Construction
Q00688184-I1-GC
04/21/2022
Objection raised — Inspections
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Zoning
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Zoning
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Zoning
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Zoning
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Admin
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Scope
04/21/2022
Objection resolved — Addressed
04/21/2022
Objection raised — Structural
04/21/2022
Objection resolved — Addressed
04/20/2022
Objection raised — Admin
04/20/2022
Objection resolved — Addressed
04/16/2022
Filed — Alteration
JOB TO RESTORE A DETACHED GARAGE TO THE PRIOR HEIGHT LEGAL CONDITION AND LEGALIZE EXISTING SIDE EXTENSION, TO CURE VIOLATION 35441817X. NO CHANGE IN USE, EGRESS OR OCCUPANCY.
Q00688184-I1
04/16/2022
Filed — Alteration
PLUMBING WORK TO REMOVE BATHROOM PLUMBING FIXTURES (SINK AND LAVATORY) IN CONJUNCTION WITH GCJOB# Q00688184, TO REMOVE VIOLATION # 35441817X
Q00692512-I1
04/07/2022
Special inspection requirement — Energy Code Compliance Inspections
ALDO BRAVO
04/07/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALDO BRAVO
04/07/2022
Special inspection requirement — Energy Code Compliance Inspections
ALDO BRAVO
03/31/2022
Special inspection requirement — Fire-Resistant Penetrations and Joints
ALDO BRAVO
03/31/2022
Special inspection requirement — Structural Stability – Alterations of existing buildings
ALDO BRAVO
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
03/09/2018$840K—— → —$339/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
FRANCISCO D PEREZ PE204/16/2022
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
JCS EXPEDITING INC203/21/2026
RP DEVELOPMENT GROUP203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
PNA CONTRACTING CORPGeneral Contractor107/08/2026
AP PLUMBING & HVAC LLCPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
CENTURY TESTING & CONSULT4081204/16/2022
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWPlumbingSigned-offCROSSFIELD PLBG.&HTG10/01/2024
DOB NOWGeneral ConstructionSigned-offPNA CONTRACTING CORP03/29/2024
▾Field Inspections (DOB CAP) — 2
DateTypeResultReport
04/01/2025Pass-Final General Construction Non-Directive 14PassView ↗
12/27/2024Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 5
DateRequirementInspectorRole
04/07/2022Energy Code Compliance InspectionsALDO BRAVOprogress
04/07/2022Fire-Resistant Penetrations and JointsALDO BRAVOspecial
04/07/2022Energy Code Compliance InspectionsALDO BRAVOprogress
03/31/2022Fire-Resistant Penetrations and JointsALDO BRAVOspecial
03/31/2022Structural Stability – Alterations of existing buildingsALDO BRAVOspecial
▾Documents — 11 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch2
08/15/2026Q00692512-I1Request digital key ↗
08/15/2026Q00688184-I1Request digital key ↗
▸Seals & Professional Certifications7
▸DOB NOWSpecial Inspector Seal & Signature3
09/02/2026Q00692512-I1Open ↗
09/01/2026Q00688184-I1Open ↗
09/01/2026Q00688184-I1Open ↗
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/13/2026Q00688184-I1Open ↗
08/13/2026Q00692512-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/02/2026Q00692512-I1Open ↗
09/01/2026Q00688184-I1Open ↗
▸Environmental & Asbestos2
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/13/2026Q00692512-I1Open ↗
08/13/2026Q00688184-I1Open ↗