← Back
Elevator cooperative
139 EAST 36 STREET
MANHATTAN · Murray Hill-Kips Bay · BIN 1018954
💬 Discuss this project
1930Year Built
6Stories
D4Building Class
R8BZoning
13,204 sfGross Floor Area
6Units
Rent Stabilized11 Open Violations ▸
Elevator cooperative · 2,271 sf lot · 5.81 FAR built · Flood zone X
Locations of Work
ArchitectureElectricalPlumbingGeneral
Floor 24p · 2 filings · 6 docs
Floor 1
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
139 E 36ST CORP103/22/2026
139 EAST 36TH STREET503/21/2026
139 EAST 36403/21/2026
▾Design Consultants (Architect / Engineer of Record)
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Rigid Structural Design, LLC203/21/2026
DOMANI CONSULTING403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
INTERSYSTEMS INSTAL S&SGeneral Contractor603/21/2026
STELLAR INDUSTRIES INCGeneral Contractor507/08/2026
LYTER GROUP INCGeneral Contractor303/21/2026
TROADIO MENENDEZElectrical103/21/2026
BHY CONTRACTOR INCGeneral Contractor107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
5D ARCH. & ENG., PLLC2781201/23/2023
KIMBERLY PECK ARCHITECT,6812109/21/2021
JACK GREEN ASSOCIATES4221—
Building Lifecycle
All (61)Filed (6)Permit Issued (7)Signed Off (3)Violation (28)Special Inspection (17)
04/29/2026
Violation issued (HPD, open)
A
11/17/2025
Violation issued (HPD, open)
I
06/04/2025
Violation issued (HPD, open)
A
11/22/2024
Violation issued (HPD, open)
I
09/30/2024
Signed off — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00942831-I1
09/30/2024
Signed off — Alteration
M00932970-I1
05/30/2024
Signed off — Alteration
revised drawings to incorporate as built conditions
M00515214-I1
04/01/2024
Violation issued (HPD, open)
A
11/22/2023
Permit issued — Supported Scaffold
M00942831-I1-SF
11/21/2023
Filed — Alteration
Installation of a temporarily supported scaffold per plan submitted. Work shall comply with 2022 building codes chapter 33. No change in use, egress and/or occupancy with this application.
M00942831-I1
11/15/2023
Filed — Alteration
M00932970-I1
11/15/2023
Permit issued — Sidewalk Shed
M00932970-I1-SH
11/15/2023
Violation issued (HPD, open)
I
09/08/2023
Permit issued — General Construction
M00515214-I1-GC
03/15/2023
Violation issued (HPD, open)
A
01/25/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Keith Striga
01/25/2023
Special inspection requirement — Energy Code Compliance Inspections
Keith Striga
01/25/2023
Special inspection requirement — Final
Keith Striga
01/25/2023
Special inspection requirement — Interior lighting power
Keith Striga
01/25/2023
Special inspection requirement — Insulation placement and R values
Keith Striga
01/25/2023
Special inspection requirement — Lighting in dwelling units
Keith Striga
01/25/2023
Special inspection requirement — Fenestration air leakage
Keith Striga
01/23/2023
Filed — Alteration
revised drawings to incorporate as built conditions
M00515214-P1
01/20/2023
Special inspection requirement — Lighting in dwelling units
Keith Striga
01/20/2023
Special inspection requirement — Insulation placement and R values
Keith Striga
01/20/2023
Special inspection requirement — Interior lighting power
Keith Striga
01/20/2023
Special inspection requirement — Fenestration air leakage
Keith Striga
01/20/2023
Special inspection requirement — Fire-Resistant Penetrations and Joints
Keith Striga
01/20/2023
Special inspection requirement — Energy Code Compliance Inspections
Keith Striga
01/20/2023
Special inspection requirement — Final
Keith Striga
11/02/2022
Violation issued (HPD, open)
I
09/22/2022
Permit issued — General Construction
M00515214-I1-GC
02/17/2022
Permit issued — General Construction
M00515214-I1-GC
02/15/2022
Violation issued (HPD, open)
A
02/15/2022
Violation issued (HPD, open)
I
12/08/2021
Special inspection requirement — Post-installed Anchors
JACK GREEN
12/08/2021
Special inspection requirement — Final
JACK GREEN
12/08/2021
Special inspection requirement — Mechanical Systems
JACK GREEN
09/21/2021
Filed — Alteration
M00577785-I1
09/21/2021
Filed — Alteration
relocate and install plumbing fixtures in Apt. #2 on the 2nd floor. GC filed under M00577785
M00577793-I1
08/13/2021
Permit issued — General Construction
M00515214-I1-GC
05/27/2021
Permit issued — General Construction
M00515214-I1-GC
05/05/2021
Filed — Alteration
revised drawings to incorporate as built conditions
M00515214-I1
04/01/2021
Violation issued (HPD, open)
A
03/07/2016
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/27/2015
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
01/16/2014
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/04/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/03/2013
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
02/08/2011
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
08/27/2010
Violation issued (ECB, closed)
Elevators
09/29/2008
Violation issued (ECB, closed)
Unknown
09/29/2008
Violation issued (ECB, closed)
Cranes and Derricks
09/29/2008
Violation issued (ECB, closed)
Unknown
09/29/2008
Violation issued (ECB, closed)
Unknown
03/03/2008
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
04/18/2007
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/30/2006
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
10/01/2003
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
06/28/2000
Violation issued (DOB, closed)
V*-DOB VIOLATION - Resolved
Latest 60 of 61 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSupported ScaffoldSigned-offINTERSYSTEMS INSTAL S&S11/22/2023
DOB NOWSidewalk ShedSigned-offINTERSYSTEMS INSTAL S&S11/15/2023
DOB NOWGeneral ConstructionSigned-offBHY CONTRACTOR INC09/08/2023
DOB NOWGeneral ConstructionSigned-offSTELLAR INDUSTRIES INC09/22/2022
DOB NOWGeneral ConstructionSigned-offSTELLAR INDUSTRIES INC02/17/2022
DOB NOWGeneral ConstructionSigned-offSTELLAR INDUSTRIES INC08/13/2021
DOB NOWGeneral ConstructionSigned-offLYTER GROUP INC05/27/2021
BISBLISSUEDKEW FOREST PLBG & HTG INC01/06/2017
BISPLISSUEDKEW FOREST PLBG & HTG INC09/30/2016
BISOTISSUEDLINDEN MARSHALL CONTRACTING INC09/27/2016
BISEQISSUEDROCKLEDGE SCAFFOLD CORP09/30/2008
BISEQISSUEDROCKLEDGE SCAFFOLD CORP09/30/2008
1 project · most recent 09/21/2021
Gas Water/Sanitary
FiledStatusContractorScope
09/21/2021——Gas, Water/Sanitary
2 projects · most recent 11/17/2023
General Wiring
FiledStatusContractorScope
11/17/2023Permit IssuedAUR0RA ELECL CONTG INC—
09/07/2021Permit IssuedMARTINEZ ELECTRICAL CONTGeneral Wiring
1 project
Steel
FiledStatusContractorScope
———Steel
▾Special Inspection Requirements (DOB NOW) — 17
DateRequirementInspectorRole
01/25/2023Fire-Resistant Penetrations and JointsKeith Strigaspecial
01/25/2023Energy Code Compliance InspectionsKeith Strigaprogress
01/25/2023FinalKeith Strigaprogress
01/25/2023Interior lighting powerKeith Strigaenergy_progress
01/25/2023Insulation placement and R valuesKeith Strigaenergy_progress
01/25/2023Lighting in dwelling unitsKeith Strigaenergy_progress
01/25/2023Fenestration air leakageKeith Strigaenergy_progress
01/20/2023Lighting in dwelling unitsKeith Strigaenergy_progress
01/20/2023Insulation placement and R valuesKeith Strigaenergy_progress
01/20/2023Interior lighting powerKeith Strigaenergy_progress
01/20/2023Fenestration air leakageKeith Strigaenergy_progress
01/20/2023Fire-Resistant Penetrations and JointsKeith Strigaspecial
01/20/2023Energy Code Compliance InspectionsKeith Strigaprogress
01/20/2023FinalKeith Strigaprogress
12/08/2021Post-installed AnchorsJACK GREENspecial
12/08/2021FinalJACK GREENprogress
12/08/2021Mechanical SystemsJACK GREENspecial
▾Documents — 86 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
09/06/2026M00653802-I1Request digital key ↗
09/03/2026M00515214-I1Request digital key ↗
09/03/2026M00515214-P1Request digital key ↗
Showing 3 of 7 on file for this type
▸Applications & Permits15
▸BISPLAN / WORK APPROVAL APPLICATION9
08/09/2017122792077Open ↗
08/03/2017122792077Open ↗
07/06/2017122792077Open ↗
Showing 3 of 9 on file for this type
▸BISWORK PERMIT APPLICATION6
01/09/2017122792077Open ↗
10/11/2016122792077Open ↗
10/06/2016122792077Open ↗
Showing 3 of 6 on file for this type
▸Seals & Professional Certifications25
▸DOB NOWDPL-1: Design Professional Seal & Signature7
09/06/2026M00653802-I1Open ↗
09/03/2026M00515214-I1Open ↗
09/03/2026M00577785-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature7
08/27/2026M00644154-I1Open ↗
08/25/2026M00515214-P1Open ↗
08/25/2026M00515214-P1Open ↗
Showing 3 of 7 on file for this type
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION5
01/30/2018122792077Open ↗
08/10/2016122792077Open ↗
06/09/2016122792077Open ↗
Showing 3 of 5 on file for this type
▸BISPROFESSIONAL CERTIFIED CHECKLIST2
09/26/2008110278878Open ↗
09/25/2008110251799Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT FORM2
09/26/2008110278878Open ↗
09/24/2008110251799Open ↗
▸DOB NOWSpecial Inspector Seal & Signature2
08/25/2026M00515214-P1Open ↗
08/24/2026M00515214-I1Open ↗
▸Trade Schedules & Equipment7
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE4
07/06/2017122792077Open ↗
08/18/2016122792077Open ↗
08/15/2016122792077Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE C - HEATING & COMBUSTION EQUIPMENT3
08/09/2017122792077Open ↗
08/03/2017122792077Open ↗
08/10/2016122792077Open ↗
▸Safety & Tenant Protection1
▸BISTenant Protection Plan and Notes1
06/09/2016122792077Open ↗
▸Environmental & Asbestos10
▸DOB NOWDEP ACP-5: Asbestos Assessment Report6
09/06/2026M00653802-I1Open ↗
09/06/2026M00644154-I1Open ↗
09/03/2026M00515214-I1Open ↗
Showing 3 of 6 on file for this type
▸BISASBESTOS EXEMPTION CERTIFICATION LETTER2
09/26/2008110278878Open ↗
09/24/2008110251799Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)2
08/19/2016122792077Open ↗
06/09/2016122792077Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS3
08/10/2016122792077Open ↗
07/13/2016122792077Open ↗
06/09/2016122792077Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
01/30/2018122792077Open ↗
▸DOB NOWEN2: As Built Energy Analysis.1
08/13/2026M00515214-I1Open ↗
▸Approvals, Objections & Sign-offs3
▸BISADMINISTRATIVE OBJECTIONS2
09/26/2008110278878Open ↗
09/24/2008110251799Open ↗
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST1
01/30/2018122792077Open ↗
▸Cost, Insurance & Ownership3
▸BISCOST AFFIDAVIT3
01/30/2018122792077Open ↗
07/13/2016122792077Open ↗
06/09/2016122792077Open ↗
▸Filing & Intake Forms10
▸BISADDITIONAL INFORMATION5
08/22/2017122792077Open ↗
08/09/2017122792077Open ↗
08/03/2017122792077Open ↗
Showing 3 of 5 on file for this type
▸BISEFILING COVER SHEET4
07/12/2016122792077Open ↗
06/09/2016122792077Open ↗
09/26/2008110278878Open ↗
Showing 3 of 4 on file for this type
▸BISBOROUGH INTAKE FORM1
01/30/2018122792077Open ↗