← Back
Converted dwellings or rooming house
1397 STEBBINS AVENUE
BRONX · BIN 2010249
💬 Discuss this project
1909Year Built
4Stories
C5Building Class
R7-1Zoning
11,360 sfGross Floor Area
24Units
Rent Stabilized0 Open Violations
Converted dwellings or rooming house · 4,000 sf lot · 2.84 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingFire Protection
Permit Issued — active, not yet Signed-off
RoofUnder Construction5p · 1 filing · 6 docs
Floor 4Under Construction60p · 3 filings · 20 docs
Floor 3Under Construction49p · 3 filings · 20 docs
Floor 2Under Construction49p · 3 filings · 20 docs
Floor 1Under Construction60p · 3 filings · 20 docs
CellarUnder Construction2p · 1 filing · 3 docs
Basement50p · 1 filing · 20 docs
Sub-BasementUnder Construction4p · 1 filing · 6 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
MATILDA AVE PROPERTY1607/08/2026
STEBBINS707/08/2026
STEBBINS MANAGEMENT LTD503/22/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
EDWARD DICKMAN ARCHITECT310/18/2023
GEA CONSULTING ENGINEERS208/01/2023
PRAMODRAY SHAH, P.E.212/15/2021
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
M W EXPEDITING1403/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
LIME STONE BUILDERS INCGeneral Contractor1007/08/2026
CYM ELECTRICAL CONTRACTORElectrical103/22/2026
CASINO PLMBG & HTG CORPFire Protection107/08/2026
PRIME PIPING & HEATING INFire Protection107/08/2026
L.L.G. PLBG & HTG INCPlumbing106/28/2026
PRIME PIPING & HEATING INPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
ACV DESIGN LTD3864310/18/2023
SHAHRISH SHUVO ENGINEERIN8524106/20/2023
SJS INSPECTIONS AND CONSU8286112/15/2021
Building Lifecycle
All (99)Filed (7)Permit Issued (8)Violation (26)Inspection (16)Objection (26)Special Inspection (16)
07/07/2026
Inspection — Certified Remove/Cap - work done in accordance with code
Certified
View inspection ↗
06/18/2026
Permit issued — Sprinklers
X00886335-I1-EW-SP
06/18/2026
Permit issued — Plumbing
X00596526-I1-PL
12/05/2025
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
11/17/2025
Violation issued (HPD, closed)
I
07/23/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
05/29/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
03/21/2025
Inspection — Certified Gas-Gas-Piping-Roughing
Certified
View inspection ↗
03/21/2025
Inspection — Certified Storm Drainage-ST-Piping-Roughing
Certified
View inspection ↗
03/21/2025
Inspection — Certified Storm Drainage-ST-Piping-Underground
Certified
View inspection ↗
03/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
03/21/2025
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
01/14/2025
Inspection — Pass-Final CND-Occupancy Inspection
Pass
View inspection ↗
12/18/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
12/05/2024
Inspection — Fail-Final CND-Occupancy Inspection
Fail
View inspection ↗
09/20/2024
Inspection — Certified Sprinkler-SP-Fixtures-Finish
Certified
View inspection ↗
09/17/2024
Inspection — Certified Sprinkler (SP) - Booster Pump Test
Certified
View inspection ↗
09/17/2024
Inspection — Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic Test
Certified
View inspection ↗
06/26/2024
Permit issued — Mechanical Systems
X00596214-I1-GC-CX
04/23/2024
Permit issued — General Construction
X00596214-I1-GC-CX
10/18/2023
Filed — Alteration CO
Renovation of existing residential building. Work to include adding additional rooms.
X00596214-P3
10/18/2023
Special inspection requirement — Mechanical Systems
ANTHONY VILLANO
10/18/2023
Special inspection requirement — Final
EDWARD DICKMAN
10/18/2023
Special inspection requirement — Fenestration areas
EDWARD DICKMAN
10/18/2023
Special inspection requirement — Fenestration air leakage
EDWARD DICKMAN
10/18/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
EDWARD DICKMAN
10/10/2023
Filed — Alteration CO
Renovation of existing residential building. Work to include adding additional rooms.
X00596214-P2
09/29/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Roughing
Certified
View inspection ↗
09/29/2023
Inspection — Certified Water and Sanitary-WS-Sanitary Piping-Underground
Certified
View inspection ↗
09/27/2023
Permit issued — General Construction
X00596214-I1-GC-CX
09/21/2023
Special inspection requirement — Mechanical Systems
ANTHONY VILLANO
09/21/2023
Special inspection requirement — Final
EDWARD DICKMAN
09/21/2023
Special inspection requirement — Fenestration and door U-factor and product ratings
EDWARD DICKMAN
09/21/2023
Special inspection requirement — Fenestration areas
EDWARD DICKMAN
09/21/2023
Special inspection requirement — Fenestration air leakage
EDWARD DICKMAN
08/08/2023
Permit issued — Sprinklers
X00886335-I1-EW-SP
08/01/2023
Filed — Alteration
Sprinkler work being filed throughout. No change to use, egress or occupancy.
X00886335-P1
07/31/2023
Special inspection requirement — Sprinkler Systems
07/20/2023
Objection resolved — Addressed
07/20/2023
Objection resolved — Addressed
07/05/2023
Objection resolved — Addressed
06/28/2023
Objection raised — Admin
06/28/2023
Objection raised — Cost
06/28/2023
Objection raised — Admin
06/20/2023
Filed — Alteration
Sprinkler work being filed throughout. No change to use, egress or occupancy.
X00886335-I1
06/17/2023
Permit issued — Plumbing
X00596526-I1-PL
03/17/2023
Violation issued (HPD, closed)
A
12/29/2022
Filed — Alteration CO
Renovation of existing residential building. Work to include adding additional rooms.
X00596214-P1
12/29/2022
Special inspection requirement — Mechanical Systems
ANTHONY VILLANO
12/29/2022
Special inspection requirement — Final
EDWARD DICKMAN
12/29/2022
Special inspection requirement — Fenestration air leakage
EDWARD DICKMAN
12/29/2022
Special inspection requirement — Fenestration and door U-factor and product ratings
EDWARD DICKMAN
12/29/2022
Special inspection requirement — Fenestration areas
EDWARD DICKMAN
10/27/2022
Permit issued — Mechanical Systems
X00596214-I1-GC-CX
09/23/2022
Objection raised — Admin
09/23/2022
Objection resolved — Addressed
07/26/2022
Objection raised — C/O of existing property requi
07/26/2022
Objection resolved — Addressed
06/08/2022
Objection raised — Admin
06/08/2022
Objection resolved — Addressed
Latest 60 of 99 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSprinklersPermit IssuedCASINO PLMBG & HTG CORP06/18/2026
DOB NOWPlumbingPermit IssuedL.L.G. PLBG & HTG INC06/18/2026
DOB NOWMechanical SystemsPermit IssuedLIME STONE BUILDERS INC06/26/2024
DOB NOWGeneral ConstructionPermit IssuedLIME STONE BUILDERS INC04/23/2024
DOB NOWGeneral ConstructionPermit IssuedLIME STONE BUILDERS INC09/27/2023
DOB NOWSprinklersPermit IssuedA M B MECHANICAL INC08/08/2023
DOB NOWPlumbingPermit IssuedPRIME PIPING & HEATING IN06/17/2023
DOB NOWMechanical SystemsPermit IssuedLIME STONE BUILDERS INC10/27/2022
BISBLISSUEDASTAS FUEL OIL10/19/1998
1 project · most recent 10/18/2023
Air Conditioning Systems
FiledStatusContractorScopeMake / Model / Capacity
10/18/2023Permit IssuedLIME STONE BUILDERS INCAir Conditioning Systems
Cooling
Lg ARNU483M3A4 48,100 BTU · Vrf Indoor ×36
ARUM096BTE5 96,000 BTU · Vrf Outdoor ×16
ARNU243M1A4 24,200 BTU · Vrf Indoor ×4
ARUM072BTE5 72,000 BTU · Vrf Outdoor ×4
1 project · most recent 08/01/2023
FiledStatusContractorScope
08/01/2023Permit IssuedCASINO PLMBG & HTG CORP—
1 project · most recent 12/15/2021
Gas Water/Sanitary
FiledStatusContractorScope
12/15/2021Permit IssuedL.L.G. PLBG & HTG INCGas, Water/Sanitary
1 project · most recent 09/05/2024
General Wiring
FiledStatusContractorScope
09/05/2024CompleteCYM ELECTRICAL CONTRACTORGeneral Wiring
▾Field Inspections (DOB CAP) — 16
DateTypeResultReport
07/07/2026Certified Remove/Cap - work done in accordance with codeCertifiedView ↗
07/23/2025Pass-Final CND-Occupancy InspectionPassView ↗
05/29/2025Pass-Final CND-Occupancy InspectionPassView ↗
03/21/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
03/21/2025Certified Storm Drainage-ST-Piping-RoughingCertifiedView ↗
03/21/2025Certified Storm Drainage-ST-Piping-UndergroundCertifiedView ↗
03/21/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
03/21/2025Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
01/14/2025Pass-Final CND-Occupancy InspectionPassView ↗
12/18/2024Fail-Final CND-Occupancy InspectionFailView ↗
12/05/2024Fail-Final CND-Occupancy InspectionFailView ↗
09/20/2024Certified Sprinkler-SP-Fixtures-FinishCertifiedView ↗
09/17/2024Certified Sprinkler (SP) - Booster Pump TestCertifiedView ↗
09/17/2024Certified Sprinkler-SP-Piping Dry/Wet-Hydrostatic TestCertifiedView ↗
09/29/2023Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
09/29/2023Certified Water and Sanitary-WS-Sanitary Piping-UndergroundCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 16
DateRequirementInspectorRole
10/18/2023Mechanical SystemsANTHONY VILLANOspecial
10/18/2023FinalEDWARD DICKMANprogress
10/18/2023Fenestration areasEDWARD DICKMANenergy_progress
10/18/2023Fenestration air leakageEDWARD DICKMANenergy_progress
10/18/2023Fenestration and door U-factor and product ratingsEDWARD DICKMANenergy_progress
09/21/2023Mechanical SystemsANTHONY VILLANOspecial
09/21/2023FinalEDWARD DICKMANprogress
09/21/2023Fenestration and door U-factor and product ratingsEDWARD DICKMANenergy_progress
09/21/2023Fenestration areasEDWARD DICKMANenergy_progress
09/21/2023Fenestration air leakageEDWARD DICKMANenergy_progress
07/31/2023Sprinkler Systems—special
12/29/2022Mechanical SystemsANTHONY VILLANOspecial
12/29/2022FinalEDWARD DICKMANprogress
12/29/2022Fenestration air leakageEDWARD DICKMANenergy_progress
12/29/2022Fenestration and door U-factor and product ratingsEDWARD DICKMANenergy_progress
12/29/2022Fenestration areasEDWARD DICKMANenergy_progress
▾Documents — 38 on file (BIS + DOB NOW)
▸Plans & Drawings7
▸DOB NOWPlans/Sketch7
08/22/2026X00886335-I1Request digital key ↗
08/22/2026X00886335-P1Request digital key ↗
08/22/2026X00596214-P3Request digital key ↗
Showing 3 of 7 on file for this type
▸Seals & Professional Certifications16
▸DOB NOWDPL-1: Design Professional Seal & Signature7
08/22/2026X00886335-I1Open ↗
08/22/2026X00886335-P1Open ↗
08/13/2026X00596526-I1Open ↗
Showing 3 of 7 on file for this type
▸DOB NOWProgress Inspector Seal & Signature6
09/01/2026X00596214-P3Open ↗
09/01/2026X00596214-P3Open ↗
08/26/2026X00596214-P2Open ↗
Showing 3 of 6 on file for this type
▸DOB NOWSpecial Inspector Seal & Signature3
09/01/2026X00596214-P3Open ↗
08/26/2026X00596214-P2Open ↗
08/23/2026X00596214-P1Open ↗
▸Safety & Tenant Protection4
▸DOB NOWStreet Tree Checklist4
08/13/2026X00596214-P1Open ↗
08/13/2026X00596214-P2Open ↗
08/13/2026X00596214-I1Open ↗
Showing 3 of 4 on file for this type
▸Environmental & Asbestos7
▸DOB NOWDEP ACP-5: Asbestos Assessment Report7
08/22/2026X00886335-P1Open ↗
08/22/2026X00886335-I1Open ↗
08/13/2026X00596214-I1Open ↗
Showing 3 of 7 on file for this type
▸Other Documents4
▸DOB NOWProperty Ownership Certification4
08/13/2026X00596214-I1Open ↗
08/13/2026X00596214-P1Open ↗
08/13/2026X00596214-P2Open ↗