| Owner | Filings | Most Recent |
|---|---|---|
| NYC School Construction Authority | 70 | 08/29/2026 |
| NYC Department of Education | 4 | 03/22/2026 |
| S&W Wilson | 1 | 03/21/2026 |
| New York City Public School | 1 | 03/21/2026 |
| Firm | Filings | Most Recent |
|---|---|---|
| Keri Engineering | 7 | 05/07/2026 |
| Neville Burrows | 1 | 09/08/2025 |
| Stantec Architecture | 2 | 05/01/2025 |
| Superstructures Engineering + Architects | 1 | 03/04/2025 |
| Massa Multimedia Architects | 1 | 02/28/2025 |
| Hartland Engineering | 1 | 02/28/2025 |
| AK Consulting Services | 4 | 10/15/2024 |
| MSS Engineering | 2 | 04/21/2020 |
| Representative | Filings | Most Recent |
|---|---|---|
| AK Consulting Services | 8 | 03/21/2026 |
| JMV Associates | 12 | 03/21/2026 |
| Firm | Trade | Roles | Most Recent |
|---|---|---|---|
| Granite Environmental | Scaffold | 14 | 07/08/2026 |
| Kel-Tech Construction | Scaffold | 9 | 07/08/2026 |
| Granite Environmental | General Contractor | 6 | 07/08/2026 |
| Charan Electrical Enterp's | Electrical | 2 | 03/22/2026 |
| AL-Lectric Elect'l Contracting | Electrical | 1 | 03/21/2026 |
| Agency | License # | Filings | Most Recent |
|---|---|---|---|
| JPC Logistics Dba JPCL EN | 351 | 1 | 09/08/2025 |
| Universal Testing and Ins | 400 | 4 | 05/01/2025 |
| Source | Work Type | Status | Applicant | Issued |
|---|---|---|---|---|
| DOB NOW | General Construction | Signed-off | Granite Environmental | 03/18/2026 |
| DOB NOW | General Construction | Signed-off | Granite Environmental | 03/05/2025 |
| DOB NOW | Sidewalk Shed | Signed-off | Granite Environmental | 01/23/2025 |
| DOB NOW | Construction Fence | Signed-off | Granite Environmental | 01/22/2025 |
| DOB NOW | Construction Fence | Signed-off | Granite Environmental | 02/28/2024 |
| DOB NOW | Supported Scaffold | Permit Issued | Granite Environmental | 01/24/2024 |
| DOB NOW | General Construction | Signed-off | Granite Environmental | 01/24/2024 |
| DOB NOW | Sidewalk Shed | Signed-off | Granite Environmental | 01/24/2024 |
| DOB NOW | General Construction | Signed-off | Granite Environmental | 04/07/2023 |
| DOB NOW | Supported Scaffold | Permit Issued | Granite Environmental | 04/03/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | Granite Environmental | 03/16/2023 |
| DOB NOW | Construction Fence | Signed-off | Granite Environmental | 03/09/2023 |
| DOB NOW | Sidewalk Shed | Signed-off | Kel-Tech Construction | 04/14/2022 |
| DOB NOW | Supported Scaffold | Signed-off | Kel-Tech Construction | 04/14/2022 |
| DOB NOW | Sidewalk Shed | Signed-off | Kel-Tech Construction | 04/06/2021 |
| DOB NOW | Supported Scaffold | Signed-off | Kel-Tech Construction | 04/06/2021 |
| DOB NOW | Sidewalk Shed | Signed-off | Kel-Tech Construction | 01/26/2021 |
| DOB NOW | Supported Scaffold | Signed-off | Kel-Tech Construction | 01/26/2021 |
| DOB NOW | Supported Scaffold | Signed-off | Kel-Tech Construction | 04/30/2020 |
| DOB NOW | Sidewalk Shed | Signed-off | Kel-Tech Construction | 04/21/2020 |
| BIS | OT | ISSUED | Pro-Metal Construction | 10/28/2019 |
| BIS | OT | ISSUED | Pro-Metal Construction | 10/28/2019 |
| BIS | OT | ISSUED | Pro-Metal Construction | 10/24/2018 |
| BIS | OT | ISSUED | Pro-Metal Construction | 10/24/2018 |
| BIS | OT | ISSUED | Pro-Metal Construction | 10/24/2018 |
| BIS | OT | ISSUED | Pro-Metal Construction | 04/24/2018 |
| BIS | OT | ISSUED | Pro-Metal Construction | 04/24/2018 |
| BIS | OT | ISSUED | Pro-Metal Construction | 04/24/2018 |
| BIS | OT | ISSUED | Pro-Metal Construction | 04/24/2018 |
| BIS | PL | ISSUED | Varsity Plumbing and Heating | 08/21/2017 |
| BIS | PL | ISSUED | Varsity Plumbing and Heating | 07/31/2017 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/10/2017 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/10/2017 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/10/2017 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/10/2017 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/05/2017 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/05/2017 |
| BIS | PL | ISSUED | Varsity Plumbing and Heating | 03/02/2017 |
| BIS | PL | ISSUED | Varsity Plumbing and Heating | 08/01/2016 |
| BIS | OT | ISSUED | Pro-Metal Construction | 05/09/2016 |
| Filed | Status | Contractor | Scope | Make / Model / Capacity |
|---|---|---|---|---|
| 05/07/2026 | — | — | Air Conditioning Systems, Heating and Air Conditioning Systems, Heating Systems, Ventilation Systems | Cooling Mitsubishi Electric PKA-A18LA 18,000 BTU · Fan Coil Indoor ×2 PUY-A18NKA7 18,000 BTU · Condensing Unit ×2 Heat / Cool Daikin FCVC102 220 CFM ×7 Heating Berko PHFP25 6,398 BTU · Electric Heater ×18 Jetson ACCM-060 53 tons · Condensing Unit ×5 Johnson Controls XTI-36X51 3,000 CFM · Fan Coil Indoor ×1 Ventilation Johnson Controls XTI-42X51 3,700 CFM · Chiller ×3 XTI-42X75 6,500 CFM ×1 XTI-42X81 7,500 CFM ×1 XTI-45X51 3,500 CFM ×1 XTI-45X54 4,000 CFM ×1 |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/07/2026 | — | — | 9 heads |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/07/2026 | — | — | Gas, Water/Sanitary |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 09/12/2024 | Complete | Charan Electrical Enterp's | — |
| 05/09/2023 | Complete | Selectric Electrical Cont Co I | — |
| 05/09/2023 | Complete | Selectric Electrical Cont Co I | General Wiring |
| 02/04/2022 | Complete | Stanco System Electrical Cont | — |
| 02/21/2020 | Permit Issued | Samco Electric | — |
| 01/21/2020 | Complete | Charan Electrical Enterp's | — |
| 08/14/2019 | Complete | Charan Electrical Enterp's | 2 meters, 2 new_meters |
| 05/10/2019 | Complete | Multi-Tech Electric | General Wiring |
| Filed | Status | Contractor | Scope |
|---|---|---|---|
| 05/07/2026 | — | — | Steel, Concrete |
| Date | Type | Result | Report |
|---|---|---|---|
| 05/11/2026 | Pass-Final General Construction Non-Directive 14 | Pass | View ↗ |
| Date | Requirement | Inspector | Role |
|---|---|---|---|
| 05/12/2026 | Post-installed Anchors | — | special |
| 05/12/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 05/12/2026 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | — | special |
| 05/05/2026 | Post-installed Anchors | — | special |
| 05/05/2026 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | — | special |
| 05/05/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 05/04/2026 | Lowest Floor Elevation | — | progress |
| 05/04/2026 | Fire-Resistant Penetrations and Joints | — | special |
| 05/04/2026 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | — | special |
| 05/04/2026 | Heating Systems | — | special |
| 05/04/2026 | Mechanical Systems | — | special |
| 05/04/2026 | Post-installed Anchors | — | special |
| 05/04/2026 | Final | — | progress |
| 06/02/2025 | Masonry | NELSON LOPEZ | special |
| 06/02/2025 | Post-installed Anchors | NELSON LOPEZ | special |
| 04/30/2025 | Post-installed Anchors | NELSON LOPEZ | special |
| 04/30/2025 | Masonry | NELSON LOPEZ | special |
| 04/14/2025 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | — | special |
| 04/11/2025 | Lowest Floor Elevation | — | progress |
| 04/07/2025 | Flood Zone Compliance (attach FEMA elevation/dry floodproofing certificate where applicable) | — | special |
| 04/07/2025 | Fire-Resistance Rated Construction | — | progress |
| 04/04/2025 | Heating Systems | — | special |
| 03/27/2025 | Heating Systems | — | special |
| 03/27/2025 | Post-installed Anchors | — | special |
| 03/03/2025 | Sprinkler Systems | — | special |
| Tenant | Space | Floors | Renovation projects |
|---|---|---|---|
| P.S. 171 Peter G. Van Alst | Education | Cellar, Floors 1–3, Roof | Project Q01163912 Project Q01186687 Project Q08002164 Project Q08002172 Project Q08002177 Project Q00602068 Project Q00327492 Project Q00320779 |
| P.S. 171-Queens | Education | — | Project Q01120528 |