DOB08/27/2026STRUCTURE RENDERED NON COMPLIANT AT TIME OF INSPECTION. DAMAGE OBSERVED TO HAVE BEEN SUSTAINED. PREMISES IS A 4 STORY MIXED USE NON FIRE PROOF BUILDING. SIDEWALK SHED LOCATED AT EXPOSURE ONE. SUPPORT COLUMNS AND CROSS BRACING & JUNIOR BEAMS DISLODGED DUE TO CAR IMPACT
DOB07/31/2026STRUCTURE RENDERED NON-COMPLIANT. AT TIME OF INSPECTION OBSERVED AT FRONT OF BUILDING SIDEWALK SHED AT RIGHT SIDE HAS METAL FRAME NOT STRAIGHT DUE TO MOTOR VEHICLE IMPACTING SHED.
ECB07/31/2026AT FRONT OF BUILDING SIDEWALK SHED INSTALLED. DOB RECORDS INDICATE NO PERMIT ISSUED FOR THIS WORK., OBTAIN PERMIT$2K due
ECB07/30/2026VIOLATION NUMBER 39154097K; FAILURE TO CERTIFY CORRECTION, COMPLY WITH COMMISSIONER'S ORDER$2K due
ECB07/18/2025AT FRONT OF BUILDING ERECTED SIDEWALK SHED. NO PERMITS ISSUED FOR THIS WORK., OBTAIN PERMIT$12K due
DOB06/02/2008V-DOB VIOLATION - ACTIVE
ECB03/29/2016TEMPORARY CONSTRUCTION EQUIPMENT ON SITE EXPIRED PERMIT. NOTE:OBSERVEDSIDEWALK SHED HAS BEEN ERECTED AT EXP#1. SIDEWALK SHED PERMIT #410192704 EXPIRED AT 01-06-2012. RMDY: RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB03/29/2016PEDESTRIAN PROTECTION DOES NOT MEET CODE SPECIFICIATON. FAILURE TO MAINTAIN SIDEWALK SHED.NOTE: OBSERVED SIDEWALK SHED HAS BEEN ERECTED AT EXP#1. OBSERVED: PARAPET WALL MISSING AND LOOSE PLYWOOD. COLUMNS ARENothing owed — awaiting certificate of correction
ECB12/24/2015PESDESTRIAN PROTECTION DOES NOT MEET CODE SPEC.FAILED TO MAINTAIN SIDEWALK SHED.NOTE:OBSERVED SIDEWALK SHE ERECTED @FRONT OF THE BLDG SIDEWALK SHED PARAPET WALL ARE COMING APART & ABOUT TO COLLAPSE.FAILURE TO MNothing owed — awaiting certificate of correction
ECB12/24/2015TEMP CONST EQUIPMENT ON SITE-EXPIRED PERMIT.NOTE:OBSERVED SIDEWALK SHED ARE STANDING @FRONT OF THE BLDG.SIDEWALK SHED PERMIT EXPIRED @01/06/2012.RECURRING CONDITION;SEE NOV #35100141J,#35031723N,#35132832P,#349Nothing owed — awaiting certificate of correction
ECB08/05/2015FAILED TO OBTAIN A TEMPORARY CONSTRUCTION PERMIT PRIOR TO INSTALLATIONOF SIDEWALK SHED. NOTED: AT TIME OF MY INSPECTION A SIDEWALK SHED WAS INSTALLED ON EXP#4 OF THE SITE.NO PERMIT HAS BEEN OBTAINED FOR THISNothing owed — awaiting certificate of correction
ECB08/20/2014WORK W/O A PERMIT: EXPIRED PERMIT. NOTE: SIDEWALK SHED HAVE BEEN ERECTED AT EXP#1 (ASTORIA BLVD) UNDER PERMIT #410192704-01-EQ-SM THAT EXPIRED AT 1-6-12 SEE NOV#35031723N ISSUED AT 12-30-2013. RMDY: RENEW PERMINothing owed — awaiting certificate of correction
ECB12/30/2013SEC. 28-105.1 WORK W/O A PERMIT: EXPIRED PERMIT. NOTE: SIDEWALK HAS BEEN ERECTED AT EXP #1 (ASTORIA BLVD) SIDEWALK SHED HAS BEEN ERECTED AT EXP #1 (ASTORIA BLVD) SIDEWALK SHED PERMIT #410192704-01-EQ-SH EXPIREDNothing owed — awaiting certificate of correction
ECB09/25/2012TEMPORARY CONSTRUCTION EQUIPMENT ON SITE - EXPIRED PERMIT. NOTED: SIDEWALK SHED WAS ERECTED JOB #410192704,PERMIT HAS EXPIRED. EXPIRATION DATE 1-6-12 NO RECORD OF RENEWAL W/THE DEPT OF BLDGS. REMEDY: CONFORM TONothing owed — awaiting certificate of correction
ECB02/16/2011SEC. 27-203 FAILURE TO COMPLY W/SAFETY REQUIREMENTS DURING CONSTRUCTION OPERATIONS AS PER 27-203 PORTION OF METAL DECKING LAID ON TOP OF ROOF BEAMS STICKING OUT & DECKING IN PLACE NOT SECURED W/PIECES OF CAUSINNothing owed — awaiting certificate of correction
ECB03/26/2010SEC. 3301.9.2. FAILURE TO PROVIDE/POST SIGNS AT JOB SITE PURSUANT TO SUBSECTION. NOTED: CONTRACTOR'S SIGN NOT POSTED ON EACH STREET FRONTAGE. ACTIVE PERMITS NOT POSTED (IE FENCE). REMEDY: POST SIGNS & PERMITS.Nothing owed — awaiting certificate of correction
ECB12/09/2008FAILURE TO SAFEGUARD ALL PERSONS AND PROPERTY AFFECTED BY CONST OPERATIONS WORK UNDER APPL 402657674 OBSERVED AT TIME OF INSPECTION A SECTION OF CMU WALL APPROX 40FTLX25FTH AT EXPOSURE 4 SIDE OF THE PREMISESNothing owed — awaiting certificate of correction
ECB11/18/2008FAILURE TO PROVIDE SIDEWALK SHED WHERE REQUIRED. NO SIDEWALK SHED INSTALLED AT PREMISES WHERE A 2ND, 3RD & 4TH FL IS BEING ADDED & PUBLIC PEDESTRIAN SIDEWALK IS BELOW. REMEDY: INSTALL/PROVIDE SIDEWALK SHED.Nothing owed — awaiting certificate of correction
ECB11/12/2008FAILURE TO INSTITUTE/MAINTAIN SAFETY EQUIPMENT MEASURES OR TEMPORARY CONSTRUCTION - NO GUARD RAILS INSTALLED THRUOUT BLDG. MISSING GUARD RAILS AT FL OPENINGS ON ALL FLS, OPEN ELEVATOR SHAFTS & AT BLDG EDGES.Nothing owed — awaiting certificate of correction
ECB11/12/2008FAILURE TO PROTECT & SAFEGUARD ALL PERSONS & PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. DEFECTS NOTED: AT TIME OF INSPECTION, RIGGING OF STEEL OVER SIDEWALK W/O REQUIRED PRECAUTIONS - NO PROTECTION FORNothing owed — awaiting certificate of correction
ECB11/12/2008SUPERVISION OR USE OF POWER OPERATED HOISTING MACHINE W/O A HOISTING MACHINE OPERATOR'S LICENSE. AT TIME OF INSPECTION - MEN HOISTING STEEL I-BEAM APPROX 15'0" LONG SWAYING ALONG FACADE OF BLDG. REMEDY: OBTAINNothing owed — awaiting certificate of correction