← Back
BuildNYC
One story - permanent living quarter
14-41 BURTON STREET
QUEENS · BIN 4104484
💬 Discuss this project
1955Year Built
1Stories
A2Building Class
R2AZoning
1,300 sfGross Floor Area
1Units
One story - permanent living quarter · 5,000 sf lot · 0.26 FAR built · Flood zone X
Locations of Work
ArchitectureStructuralMechanicalPlumbingGeneral
Names shown beside floors are taken automatically from the text of filed documents and may be incomplete or wrong.
RoofEnlargement of existing one family dwelling1p · 1 filing · 20 docs
AtticEnlargement of existing one family dwelling9p · 1 filing · 20 docs
Floor 2Enlargement of existing one family dwelling11p · 1 filing · 20 docs
Floor 1Enlargement of existing one family dwelling12p · 1 filing · 20 docs
CellarEnlargement of existing one family dwelling11p · 1 filing · 20 docs
Site & exteriorEnlargement of existing one family dwelling24p · 1 filing · 20 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
05/08/2024$1.2M—Private party → Private party$923/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
Nko Architect508/01/2025
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
Jenny Flores Expediting503/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
Jasa NYC GroupGeneral Contractor204/09/2026
Jasa NYC GroupScaffold207/08/2026
Doumas ElectricElectrical103/22/2026
Teka EnterprisesGeneral Contractor104/09/2026
T.N.T. Plumbing & HeatingPlumbing107/08/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
Nko Architect6811408/01/2025
Triangle Inspection & Tes7495105/22/2024
Building Lifecycle
02/10/2026
Permit expired, never signed off — General Construction
The city's record still shows this permit as issued, with no sign-off on its filing
Q01051337-I1-GC-CX
12/12/2025
Signed off — Alteration CO
NEW HOT WATER HEATING SYSTEM, BOILER SYSTEM, GAS PIPING AS WELL AS SANITARY AND DOMESTIC WATER PIPING AND FIXTURES IN CONJUNCRION WITH ENLARGEMENT AND RENOVAITON OF EXISTING 1 FAMILY DWELLING. FILED WITH ALT CO Q01051337-I1.
Q01051337-S1
10/01/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/25/2025
Inspection — Pass-Final PL - Up to 3 Requested Floors
Pass
View inspection ↗
09/16/2025
Signed off — Alteration CO
NEW HOT WATER HEATING SYSTEM, BOILER SYSTEM, GAS PIPING AS WELL AS SANITARY AND DOMESTIC WATER PIPING AND FIXTURES IN CONJUNCRION WITH ENLARGEMENT AND RENOVAITON OF EXISTING 1 FAMILY DWELLING. FILED WITH ALT CO Q01051337-I1.
Q01051337-S2
79 history events on file for this building. Sign in free to see the full history. Sign in · Create account
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWGeneral ConstructionPermit IssuedTeka Enterprises02/10/2025
DOB NOWGeneral ConstructionPermit IssuedJasa NYC Group12/03/2024
DOB NOWConstruction FenceSigned-offJasa NYC Group12/03/2024
DOB NOWPlumbingSigned-offT.N.T. Plumbing & Heating10/25/2024
DOB NOWConstruction FenceSigned-offJasa NYC Group09/30/2024
DOB NOWFoundationPermit IssuedJasa NYC Group09/30/2024
1 project · most recent 08/01/2025
Gas Water/Sanitary
FiledStatusContractorScope
08/01/2025Signed-offT.N.T. Plumbing & HeatingGas, Water/Sanitary
1 project · most recent 10/28/2026
General Wiring
FiledStatusContractorScope
10/28/2026Permit IssuedDoumas ElectricGeneral Wiring
▾Field Inspections (DOB CAP) — 5
DateTypeResultReport
10/01/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
09/25/2025Pass-Final PL - Up to 3 Requested FloorsPassView ↗
07/30/2025Fail-Final PL - Up to 3 Requested FloorsFailView ↗
02/14/2025Certified Gas-Gas-Piping-RoughingCertifiedView ↗
02/07/2025Certified Water and Sanitary-WS-Sanitary Piping-RoughingCertifiedView ↗
▾Special Inspection Requirements (DOB NOW) — 38
DateRequirementInspectorRole
09/09/2025HVAC-R and service water piping design and insulationNICHOLAS MOSHOPOULOSenergy_progress
09/09/2025HVAC-R and service water heating equipmentNICHOLAS MOSHOPOULOSenergy_progress
09/09/2025HVAC-R and service water heating system controlsNICHOLAS MOSHOPOULOSenergy_progress
09/09/2025Energy Code Compliance InspectionsNICHOLAS MOSHOPOULOSprogress
09/09/2025Fire-Resistant Penetrations and JointsNICHOLAS MOSHOPOULOSspecial
07/30/2025Fire-Resistant Penetrations and JointsNICHOLAS MOSHOPOULOSspecial
07/30/2025Energy Code Compliance InspectionsNICHOLAS MOSHOPOULOSprogress
07/30/2025HVAC-R and service water heating equipmentNICHOLAS MOSHOPOULOSenergy_progress
07/30/2025HVAC-R and service water piping design and insulationNICHOLAS MOSHOPOULOSenergy_progress
07/30/2025HVAC-R and service water heating system controlsNICHOLAS MOSHOPOULOSenergy_progress
08/21/2024Electric vehicle service equipment requirementsNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Air barrier - visual inspectionNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Interior lighting powerNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Fenestration air leakageNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Fire-Resistant Penetrations and JointsNICHOLAS MOSHOPOULOSspecial
05/15/2024Lighting controlsNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Fenestration and door U-factor and product ratingsNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Permanent certificateNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024HVAC-R and service water heating equipmentNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024HVAC-R and service water piping design and insulationNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Lighting in dwelling unitsNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Shutoff dampersNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024HVAC-R and service water heating system controlsNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024MeteringNICHOLAS MOSHOPOULOSenergy_progress
05/15/2024Heating SystemsNICHOLAS MOSHOPOULOSspecial
Latest 25 of 38.
41 filed documents on file for this building. Sign in free to see the full history. Sign in · Create account