← Back
General warehouse
14-50 128 STREET
QUEENS · College Point · BIN 4098466
💬 Discuss this project
1957Year Built
1Stories
E1Building Class
M1-1Zoning
56,000 sfGross Floor Area
2Units
LL97 Covered5 Open Violations 3 unresolved · 2 paperwork only ▸FDNY Report ↗
General warehouse · Owner of record: DAIEI TRADING CO INC · 79,500 sf lot · 0.7 FAR built · Flood zone X
Locations of Work
MechanicalFire Protection
Roof2p · 1 filing · 12 docs
Floor 22p · 1 filing · 12 docs
Floor 12p · 1 filing · 12 docs
Basement2p · 1 filing · 12 docs
▾Owner History (Filing Record)
Companies and organizations named on filings. Individual owners are not shown.
OwnerFilingsMost Recent
LIC PROPERTY MANAGEMENT LLC203/22/2026
15-09 REALTY CORP LLC203/22/2026
DNO EQUIP DEVELOPMENT403/21/2026
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
NAUDUS PROFESSIONAL ENGINEERING201/08/2024
FRANK PETRUSO ARCHITECT PC101/14/2022
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
JOHN KARALISElectrical103/21/2026
KARALIS JOHNElectrical103/21/2026
Building Lifecycle
All (80)Filed (3)Violation (19)Objection (28)Special Inspection (30)
11/06/2024
Special inspection requirement — Energy Code Compliance Inspections
11/06/2024
Special inspection requirement — Fire-Resistance Rated Construction
10/12/2024
Objection resolved — Addressed
10/12/2024
Special inspection requirement — HVAC-R and service water heating system controls
10/12/2024
Special inspection requirement — HVAC-R and service water heating equipment
10/12/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
10/02/2024
Objection raised — Other
09/27/2024
Objection resolved — Addressed
09/26/2024
Objection raised — Other
09/22/2024
Objection resolved — Addressed
09/19/2024
Objection raised — Other
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
09/13/2024
Objection resolved — Addressed
06/11/2024
Special inspection requirement — Air barrier — testing
06/11/2024
Special inspection requirement — Fenestration air leakage
06/11/2024
Special inspection requirement — Air barrier - visual inspection
05/02/2024
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/19/2024
Objection resolved — Addressed
01/19/2024
Objection resolved — Addressed
01/19/2024
Objection resolved — Addressed
01/19/2024
Objection resolved — Addressed
01/19/2024
Objection resolved — Addressed
01/18/2024
Objection raised — Scope
01/18/2024
Objection raised — Scope
01/18/2024
Objection raised — Structural
01/18/2024
Objection raised — Inspections
01/18/2024
Objection raised — Scope
01/18/2024
Objection raised — Zoning
01/18/2024
Objection raised — Structural
01/18/2024
Objection raised — Admin
01/18/2024
Objection raised — Admin
01/18/2024
Objection raised — Structural
01/18/2024
Objection raised — Other
01/08/2024
Filed — New Building
Installation of rooftop AC units, fans, and associated ductwork
Q00645309-S2
01/08/2024
Filed — New Building
Installation of rooftop AC units, fans, and associated ductwork
Q00645309-S1
01/07/2024
Special inspection requirement — Sprinkler Systems
01/07/2024
Special inspection requirement — Final
01/07/2024
Special inspection requirement — Maintenance information
01/07/2024
Special inspection requirement — Electrical motors and elevators
01/07/2024
Special inspection requirement — HVAC-R and service water heating system controls
01/07/2024
Special inspection requirement — Shutoff dampers
01/07/2024
Special inspection requirement — Interior lighting power
01/07/2024
Special inspection requirement — Lighting controls
01/07/2024
Special inspection requirement — HVAC-R and service water heating equipment
01/07/2024
Special inspection requirement — HVAC-R and service water piping design and insulation
01/07/2024
Special inspection requirement — Fire-Resistant Penetrations and Joints
01/07/2024
Special inspection requirement — Post-installed Anchors
01/07/2024
Special inspection requirement — Mechanical Systems
12/01/2023
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
05/17/2023
Violation issued (FDNY_NOV, closed)
12/01/2022
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
01/14/2022
Filed — New Building
Installation of rooftop AC units, fans, and associated ductwork
Q00645309-I1
12/15/2021
Special inspection requirement — Sprayed fire-resistant materials
12/15/2021
Special inspection requirement — Post-installed Anchors
12/15/2021
Special inspection requirement — Masonry
12/15/2021
Special inspection requirement — Fenestration areas
Latest 60 of 80 events.
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
BISOTISSUEDPROCOLD INC05/10/2016
BISMHISSUEDYUNG WAY CONSTRUCTION INC.11/03/2005
BISMHISSUEDGOODWILL MECHANICAL03/28/2005
BISPLISSUEDJOE TRUCE PLG INC04/08/2003
BISOTISSUEDC & L CONTRACTING CORP03/28/2003
BISMHISSUEDC & L CONTRACTING CORP03/27/2003
BISPLISSUEDG.N.T. MECHANICAL LLC04/13/2001
BIS—ISSUEDC & L CONTRACTING CORP06/02/2000
BIS—ISSUEDNORTHCO CONSTR. CORP.10/15/1998
BISPLISSUEDC.R.U. MECHAN & HEAT INC01/23/1997
BISOTISSUEDYUNG FA CONST01/10/1997
1 project · most recent 01/08/2024
Heating and Air Conditioning Systems Ventilation Systems
FiledStatusContractorScopeMake / Model / Capacity
01/08/2024——Heating and Air Conditioning Systems, Ventilation Systems
Heat / Cool
Trane MODEL DHC092H3RHA 100,000 BTU · Rooftop Unit ×3
MODEL DHC120H3RHA 120,000 BTU · Rooftop Unit ×3
MPDEL DHC074H3RHA 80,000 BTU · Rooftop Unit ×2
Mitsubishi Electric MODEL MUY-GL18NA 24,000 BTU · Condensing Unit ×1
MODEL MXZ-SM36NAM 36,000 BTU · Condensing Unit ×1
Ventilation
Trane MODEL DHC092H3RHA 100,000 BTU · Rooftop Unit ×3
MODEL DHC120H3RHA 120,000 BTU · Rooftop Unit ×3
MODEL DHC074H3RHA 80,000 BTU · Rooftop Unit ×2
Captiveaire MODEL A5-D.200-36D 12,000 CFM · Makeup Air ×1
1 project · most recent 01/08/2024
Gas
FiledStatusContractorScope
01/08/2024——Gas
▾Special Inspection Requirements (DOB NOW) — 30
DateRequirementInspectorRole
11/06/2024Energy Code Compliance Inspections—progress
11/06/2024Fire-Resistance Rated Construction—progress
10/12/2024HVAC-R and service water heating system controls—energy_progress
10/12/2024HVAC-R and service water heating equipment—energy_progress
10/12/2024HVAC-R and service water piping design and insulation—energy_progress
06/11/2024Air barrier — testing —energy_progress
06/11/2024Fenestration air leakage—energy_progress
06/11/2024Air barrier - visual inspection—energy_progress
01/07/2024Sprinkler Systems—special
01/07/2024Final—progress
01/07/2024Maintenance information—energy_progress
01/07/2024Electrical motors and elevators—energy_progress
01/07/2024HVAC-R and service water heating system controls—energy_progress
01/07/2024Shutoff dampers—energy_progress
01/07/2024Interior lighting power—energy_progress
01/07/2024Lighting controls—energy_progress
01/07/2024HVAC-R and service water heating equipment—energy_progress
01/07/2024HVAC-R and service water piping design and insulation—energy_progress
01/07/2024Fire-Resistant Penetrations and Joints—special
01/07/2024Post-installed Anchors—special
01/07/2024Mechanical Systems—special
12/15/2021Sprayed fire-resistant materials—special
12/15/2021Post-installed Anchors—special
12/15/2021Masonry—special
12/15/2021Fenestration areas—energy_progress
Latest 25 of 30.
▾Documents — 33 on file (BIS + DOB NOW)
▸Plans & Drawings3
▸DOB NOWPlans/Sketch3
08/23/2026Q00645309-S2Request digital key ↗
08/23/2026Q00645309-S1Request digital key ↗
08/23/2026Q00645309-I1Request digital key ↗
▸Applications & Permits2
▸BISPLAN / WORK APPROVAL APPLICATION1
05/11/2016421298660Open ↗
▸BISWORK PERMIT APPLICATION1
05/11/2016421298660Open ↗
▸Zoning, Tax Lot & Property Records3
▸DOB NOWZD1: DOB Zoning Diagram1
08/13/2026Q00645309-I1Open ↗
▸DOB NOWHouse Number Verification: TOPO Stamp1
08/13/2026Q00645309-I1Open ↗
▸DOB NOWZoning Exhibit form (1-5)1
08/13/2026Q00645309-I1Open ↗
▸Seals & Professional Certifications7
▸DOB NOWDPL-1: Design Professional Seal & Signature3
08/23/2026Q00645309-S1Open ↗
08/23/2026Q00645309-S2Open ↗
08/23/2026Q00645309-I1Open ↗
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION2
05/24/2016421298660Open ↗
05/11/2016421298660Open ↗
▸BISPROFESSIONAL CERTIFICATION STATEMENT1
05/11/2016421298660Open ↗
▸BISPROFESSIONAL CERTIFIED CHECKLIST1
05/11/2016421298660Open ↗
▸Trade Schedules & Equipment6
▸BISEQUIPMENT USE PERMITS5
06/29/2016421298660Open ↗
06/29/2016421298660Open ↗
06/29/2016421298660Open ↗
Showing 3 of 5 on file for this type
▸BISEQUIPMENT USE APPLICATION/PERMIT1
06/29/2016421298660Open ↗
▸Safety & Tenant Protection1
▸DOB NOWStreet Tree Checklist1
08/13/2026Q00645309-I1Open ↗
▸Energy Compliance3
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
05/24/2016421298660Open ↗
05/11/2016421298660Open ↗
▸BISAS-BUILT ENERGY ANALYSIS1
05/24/2016421298660Open ↗
▸Approvals, Objections & Sign-offs3
▸BISCERTIFICATE OF OCCUPANCY/LOC: REQUEST2
06/29/2016421298660Open ↗
05/24/2016421298660Open ↗
▸BISADMINISTRATIVE OBJECTIONS1
05/11/2016421298660Open ↗
▸Cost, Insurance & Ownership2
▸BISCOST AFFIDAVIT2
05/24/2016421298660Open ↗
05/11/2016421298660Open ↗
▸Filing & Intake Forms1
▸BISEFILING COVER SHEET1
05/11/2016421298660Open ↗
▸Other Documents2
▸DOB NOWProperty Ownership Certification1
08/23/2026Q00645309-I1Open ↗
▸DOB NOWLocal Law 92/94 of 2019 Sustainable Roof Zone1
08/13/2026Q00645309-I1Open ↗