← Back
Two family converted from one family
140-10 219 STREET
QUEENS · Laurelton · BIN 4280609
💬 Discuss this project
1920Year Built
2.5Stories
B3Building Class
R3XZoning
2,255 sfGross Floor Area
2Units
0 Open ViolationsFDNY Report ↗
Two family converted from one family · 4,900 sf lot · 0.46 FAR built · Flood zone X
Locations of Work
ArchitectureElectrical
Roof1p · 1 filing · 6 docs
▾Sales History (ACRIS)
DatePriceUnitSeller → Buyer$/sf
07/30/2018$462K—— → —$205/sf building
▾Design Consultants (Architect / Engineer of Record)
FirmFilingsMost Recent
GREEN RIVER ENVIRONMENTAL ENGINEERI106/17/2025
JUNG Y. SHIN LLC107/15/2019
LEAF ARCHITECTURE1—
▾Filing Representatives (Expediters)
RepresentativeFilingsMost Recent
AXONAL D SOLUTIONS203/21/2026
NY State Solar LLC203/21/2026
▾Contractors (License-Anchored)
FirmTradeRolesMost Recent
901 GREEN AVENUE BUILDERSGeneral Contractor903/21/2026
ZENA ELECTRIC INCElectrical103/22/2026
NYSS LLCGeneral Contractor104/09/2026
▾Special Inspection Agencies
AgencyLicense #FilingsMost Recent
GREEN RIVER ENVIRONMENTAL7841106/17/2025
Building Lifecycle
All (22)Filed (2)Permit Issued (4)Signed Off (1)Violation (2)Special Inspection (13)
07/29/2026
Special inspection requirement — Structural Wood Frame
07/29/2026
Special inspection requirement — Fenestration and door U-factor and product ratings
07/29/2026
Special inspection requirement — Air barrier - visual inspection
07/29/2026
Special inspection requirement — Insulation placement and R values
07/29/2026
Special inspection requirement — Preliminary
07/15/2026
Special inspection requirement — Fire-Resistant Penetrations and Joints
07/15/2026
Special inspection requirement — Energy Code Compliance Inspections
07/15/2026
Special inspection requirement — Final
06/20/2025
Permit issued — Solar
Q01242441-I1-SL
06/17/2025
Filed — Alteration
INSTALLATION OF PHOTOVOLTAIC SOLAR ARRAY ON EXISTING ROOF SYSTEM AS PER PLANS
Q01242441-I1
06/17/2025
Special inspection requirement — Energy Code Compliance Inspections
ROBERT MASONE
06/17/2025
Special inspection requirement — Final
ROBERT MASONE
06/17/2025
Special inspection requirement — Air barrier - visual inspection
ROBERT MASONE
06/17/2025
Special inspection requirement — Fire-Resistant Penetrations and Joints
ROBERT MASONE
06/17/2025
Special inspection requirement — Structural Stability – Alterations of existing buildings
ROBERT MASONE
05/12/2023
Signed off — Alteration
APPLICATION FILE TO PROPOSE 8' WOOD FENCE .
Q00193846-I1
01/22/2020
Permit issued — Construction Fence
Q00193846-I1-FN
11/20/2019
Violation issued (DOB, closed)
V*-DOB VIOLATION - DISMISSED
10/07/2019
Permit issued — Construction Fence
Q00193846-I1-FN
08/30/2019
Permit issued — Construction Fence
Q00193846-I1-FN
07/15/2019
Filed — Alteration
APPLICATION FILE TO PROPOSE 8' WOOD FENCE .
Q00193846-I1
01/08/2019
Violation issued (ECB, closed)
Construction
Permit / Filing Register
SourceWork TypeStatusApplicantIssued
DOB NOWSolarPermit IssuedNYSS LLC06/20/2025
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS01/22/2020
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS10/07/2019
DOB NOWConstruction FenceSigned-off901 GREEN AVENUE BUILDERS08/30/2019
BIS—ISSUEDOZZIE & BERKS LLC03/13/2023
BISPLISSUEDTRI CITY MECHANICAL GROUP CORP01/17/2022
BIS—ISSUEDI&L HOME IMPROVEMENT LLC08/25/2021
BISPLISSUEDTRI CITY MECHANICAL GROUP CORP01/31/2020
BIS—ISSUED901 GREEN AVENUE BUILDERS09/20/2019
3 projects · most recent 06/17/2025
General Wiring
FiledStatusContractorScope
06/17/2025Permit IssuedNY SOLAR ELECTRICAL LLC—
07/22/2021CompleteZENA ELECTRIC INCGeneral Wiring
11/15/2019CompleteAMRA ELECTRICAL CORPGeneral Wiring
1 project
Wood
FiledStatusContractorScope
———Wood
1 project · most recent 06/17/2025
FiledStatusContractorScope
06/17/2025Permit IssuedNYSS LLC34 panels, 14.62 kw, 1,156 roof_area_sqft
▾Special Inspection Requirements (DOB NOW) — 13
DateRequirementInspectorRole
07/29/2026Structural Wood Frame—progress
07/29/2026Fenestration and door U-factor and product ratings—energy_progress
07/29/2026Air barrier - visual inspection—energy_progress
07/29/2026Insulation placement and R values—energy_progress
07/29/2026Preliminary—progress
07/15/2026Fire-Resistant Penetrations and Joints—special
07/15/2026Energy Code Compliance Inspections—progress
07/15/2026Final—progress
06/17/2025Energy Code Compliance InspectionsROBERT MASONEprogress
06/17/2025FinalROBERT MASONEprogress
06/17/2025Air barrier - visual inspectionROBERT MASONEenergy_progress
06/17/2025Fire-Resistant Penetrations and JointsROBERT MASONEspecial
06/17/2025Structural Stability – Alterations of existing buildingsROBERT MASONEspecial
▾Documents — 66 on file (BIS + DOB NOW)
▸Plans & Drawings2
▸DOB NOWPlans/Sketch - Construction Fence1
08/28/2026Q00193846-I1Request digital key ↗
▸DOB NOWPlans/Sketch1
08/19/2026Q01242441-I1Request digital key ↗
▸Applications & Permits13
▸BISPLAN / WORK APPROVAL APPLICATION6
09/10/2021421687767Open ↗
08/31/2021421687767Open ↗
02/10/2021421687767Open ↗
Showing 3 of 6 on file for this type
▸BISWORK PERMIT APPLICATION5
07/27/2023421687767Open ↗
10/07/2021421687767Open ↗
02/11/2020421687767Open ↗
Showing 3 of 5 on file for this type
▸BISINTENT TO REVOKE APPROVAL/PERMIT1
01/07/2020421687767Open ↗
▸BISCERTIFICATE OF OCCUPANCY: APPLICATION1
02/01/2021421687767Open ↗
▸Zoning, Tax Lot & Property Records3
▸BISCO OBJ: VERIFY ADDRESS-TOPO STAMP1
10/23/2023421687767Open ↗
▸BISZONING DIAGRAM1
01/25/2019421687767Open ↗
▸BISVERIFY TAX LOT1
09/07/2022421687767Open ↗
▸Seals & Professional Certifications9
▸BISTECHNICAL REPORT: RESPONSIBILITY/CERTIFICATION4
08/03/2019421687767Open ↗
01/23/2019421687767Open ↗
01/23/2019421687767Open ↗
Showing 3 of 4 on file for this type
▸DOB NOWDPL-1: Design Professional Seal & Signature2
08/28/2026Q00193846-I1Open ↗
08/19/2026Q01242441-I1Open ↗
▸DOB NOWProgress Inspector Seal & Signature2
09/01/2026Q01242441-I1Open ↗
09/01/2026Q01242441-I1Open ↗
▸DOB NOWSpecial Inspector Seal & Signature1
09/01/2026Q01242441-I1Open ↗
▸Trade Schedules & Equipment6
▸BISSCHEDULE B - PLUMBING4
09/10/2021421687767Open ↗
08/31/2021421687767Open ↗
02/10/2021421687767Open ↗
Showing 3 of 4 on file for this type
▸BISSCHEDULE B - PLUMBING/SPRINKLER/STANDPIPE2
01/03/2019421687767Open ↗
11/10/2018421687767Open ↗
▸Safety & Tenant Protection2
▸BISSTREET TREE CHECKLIST1
01/23/2019421687767Open ↗
▸BISDEMOLITION SUBMITTAL CERTIFICATION FORM1
03/18/2019421687767Open ↗
▸Environmental & Asbestos3
▸DOB NOWDEP ACP-5: Asbestos Assessment Report2
08/29/2026Q01431319-I1Open ↗
08/19/2026Q01242441-I1Open ↗
▸BISASBESTOS: CERTIFICATION (DEP ACP5)1
11/10/2018421687767Open ↗
▸Energy Compliance5
▸BISTECHNICAL REPORT: ENERGY CODE PROGRESS INSPS2
08/03/2019421687767Open ↗
01/23/2019421687767Open ↗
▸BISTECHNICAL REPORT: ENERGY CODE - RESPONSIBILITY2
09/07/2022421687767Open ↗
10/22/2021421687767Open ↗
▸BISAS-BUILT ENERGY ANALYSIS (EN2)1
09/07/2022421687767Open ↗
▸Inspections & Test Reports4
▸BISTECHNICAL REPORT: RESPONSIBILITY2
09/07/2022421687767Open ↗
10/22/2021421687767Open ↗
▸BISTECHNICAL REPORT: SOIL INSPECTION1
01/23/2019421687767Open ↗
▸BISSUBSURFACE / SOILS INVESTIGATION (BORINGS/TEST PITS)1
09/08/2022421687767Open ↗
▸Approvals, Objections & Sign-offs8
▸BISSCHEDULE A - OCCUPANCY / USE5
09/10/2021421687767Open ↗
08/31/2021421687767Open ↗
02/10/2021421687767Open ↗
Showing 3 of 5 on file for this type
▸BISSUPERSEDING LETTER2
07/27/2023421687767Open ↗
10/07/2021421687767Open ↗
▸BISLETTERS - SUPPORTING DOCUMENTATION1
12/27/2019421687767Open ↗
▸Cost, Insurance & Ownership3
▸BISDEPT OF FINANCE VERIFICATION1
09/24/2019421687767Open ↗
▸BISCOST AFFIDAVIT1
01/23/2019421687767Open ↗
▸BISCOST AFFIDAVIT (FINAL): PW31
09/07/2022421687767Open ↗
▸Filing & Intake Forms7
▸BISADDITIONAL INFORMATION3
11/08/2023421687767Open ↗
10/21/2021421687767Open ↗
01/25/2019421687767Open ↗
▸BISBOROUGH INTAKE FORM3
07/27/2023421687767Open ↗
10/07/2021421687767Open ↗
10/29/2020421687767Open ↗
▸BISEFILING COVER SHEET1
11/10/2018421687767Open ↗
▸Other Documents1
▸BISPLOT DIAGRAM1
01/23/2019421687767Open ↗