HPD05/07/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD06/12/2025(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2024(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/30/2023(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/08/2022(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2021(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD12/16/2017§ 27-2046.1, 2046.2 HMC: PROVIDE AN APPROVED AND OPERATIONAL CARBON MONOXIDE DETECTING DEVICE, INSTALLED IN ACCORDANCE WITH APPLICABLE LAW AND RULES. IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY
HPD12/16/2017§ 26-1103 ADMIN. CODE: POST AND MAINTAIN A PROPER NOTICE ON WALL OF THE ENTRANCE STORY IN ENGLISH AND SPANISH ON THE AVAILABILITY OF THE AGENCYS HOUSING INFORMATION GUIDE. A SAMPLE NOTICE CAN BE FOUND AT WWW.NYC.GOV/HPD. AT PUBLIC HALL, 1st STORY
HPD12/16/2017§ 27-2045 ADM CODE POST A PROPER NOTICE OF SMOKE DETECTOR REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, AT OR NEAR THE MAIL BOX ,, AT PUBLIC HALL, 1st STORY
HPD12/16/2017§ 27-2005, 2007 ADM CODE REMOVE ALL ENCUMBRANCES CONSISTING OF STORAGE OF DISUSED HOUSE HOLD ITEMS. ETC. AT PUBLIC HALL STAIRS TO BULH-HEAD AT PUBLIC HALL, 4th STORY
HPD12/16/2017§ 27-2018 ADMIN. CODE: ABATE THE NUISANCE CONSISTING OF MICE IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY
HPD12/16/2017§ 27-2045 ADM CODE REPAIR OR REPLACE THE SMOKE DETECTOR WHICH IS MISSING IN THE ENTIRE APARTMENT LOCATED AT APT 4F, 4th STORY
HPD12/16/2017§ 27-2005 HMC: POST, IN A FORM APPROVED BY THE COMMISSIONER, AND MAINTAIN A NOTICE IN A COMMON AREA OF THE BUILDING REGARDING THE PROCEDURES THAT SHOULD BE FOLLOWED WHEN A GAS LEAK IS SUSPECTED AT PUBLIC HALL, 1st STORY
HPD12/16/2017§ 27-2046.1 HMC: POST A PROPER NOTICE OF CARBON MONOXIDE DETECTING DEVICE REQUIREMENTS, IN A FORM APPROVED BY THE COMMISSIONER, IN A COMMON AREA OF A CLASS A MULTIPLE DWELLING NEAR INSPECTION CERTIFICATE OR PROVIDE NOTICE TO TENANTS IN A PRIVATE DWELLING. AT PUBLIC HALL, 1st STORY
HPD12/16/2017§ 329, M/D LAW AND DEPT. RULES AND REGS. PROVIDE A COMPLETED CERTIFICATE OF INSPECTION VISITS IN A PROPER FRAME AT OR NEAR MAILBOXES, BOTTOM EDGE OF FRAME BETWEEN 48-62 INCHES ABOVE FLOOR FRAME MISSING. AT PUBLIC HALL, 1st STORY
HPD12/16/2017§ 27-2104 ADM CODE POST AND MAINTAIN A PROPER SIGN ON WALL OF ENTRANCE STORY SHOWING THE REGISTRATION NUMBER ASSIGNED BY THE DEPARTMENT AND THE ADDRESS OF THE BUILDING. AT PUBLIC HALL, 1st STORY
HPD12/16/2017§ 27-2005, 2007 ADM CODE REMOVE THE ILLEGAL FASTENING DOUBLE CYLINDER LOCK ON EXTERIOR METAL DOOR TO BUILDING. AT PUBLIC HALL, 1st STORY
DOB05/31/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS, 4"CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALCO NIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCES S, 60' CURB CUT, NO PARKING ATTENDANT'S BOOTH
DOB05/21/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS, 4" CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALC ONIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCE SS, 60' CURB CUT, NO PARKING ATTENDANT'S BOOTH
DOB04/06/2007V-DOB VIOLATION - ACTIVE
DOB07/10/2002V-DOB VIOLATION - ACTIVE
ECB04/05/2006WORK W/O A PERMIT: EXPIRED PERMIT JOB #401202453 EXPIRED 3/25/06 2 MEN WORKING AT ROOF LEVEL. REMEDY: STOP ALL WORK-RENEW PERMIT.Nothing owed — awaiting certificate of correction
ECB03/30/2006FAILURE TO SAFEGUARD PUBLIC AND PROPERTY AFFECTED BY CONSTRUCTION OPERATIONS. ON INSPECTION BRICK WORK IN PROGRESS APPROX AT 50' HIGH ON EXTERIOR OF BUILDING WITHOUT ANY OVER HEAD PROTECT PROVIDED TO PROTECT THNothing owed — awaiting certificate of correction
ECB03/30/2006WORK WITHOUT A PERMIT. ON INSPECTION ADDITIONAL BRICK AND CEMET BLOCK WALL HAS BEEN ADDED ON PARAPET WALL AT ROOF LEVEL. NEW WALL IS ERECTEDAT APPROX. 50' ABOVE GRADE LEVEL AND A AREA OF APPROX 6' X 14'. D.O.BNothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS ARE IMPROPERLY USED TO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION.Nothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE ACCESS TO ROOF VIA INTERIOR STAIR. NO FOOF BULKHEAD PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROVIDE REQUIRED ACCESS TO ROOF.Nothing owed — awaiting certificate of correction
ECB11/06/2002PLASTIC SKYLIGHTS TOP OF STAIR ENCLOSERE ARE NOT PERMITTED. SKY LIGHTS ARE NOT VENTED AND NO PROPER WIRE GRATTING PROVIDED ABOVE AND BELOW SKYLINGHT. REMEDY: PROVIDE PROPER SKYLING AND GRATING.Nothing owed — awaiting certificate of correction
ECB11/06/20021-HOUR RATED BOILER ENCLOSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTEGRITY OF ONE HOUR RATED WALL REMEDY - PROVIDE 1-HOUR FIRE PROTECTION AROUND BOILER FLUENothing owed — awaiting certificate of correction
ECB11/06/2002BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION ( PARAPET WALL ) REMEDY - RAISE FLUE PIPE 3 FEET ABOVE HIGHEST ROOF CONSTRUCTIONNothing owed — awaiting certificate of correction
ECB11/06/2002EXTERIOR GAS SERVICE NOT PROPERLY PROTECTED BY BOLLARDS. FROM VEHICLURS TRAFFIC AT 1ST FLOOR PARKING AREA REMEDY - PROVIDE ADDITIONAL PROTECTION AROUND GAS SERVICESNothing owed — awaiting certificate of correction
ECB11/06/2002WORK CONTRARY TO PLANS IN THAT GARAGE DIMERSIONS SMALLER THAN SPECIFICED 2 ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL AND CONCROTE3 REAR LOT RETAINING WALL NOT SHOWN ON PLANS 4 CURB CUT IS 55 FEET INNothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARENothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN OR PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE. WINDOWS.Nothing owed — awaiting certificate of correction
ECB11/06/2002GUARD RAILS ARE NOT PROVIDED AT SECTION'S OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY - PROVIDE GUARD RAILS AT PARAPET LEVEL AT ROOFNothing owed — awaiting certificate of correction
ECB11/06/2002APARTMENT DOOR OPENS DIRECTLY TO STAIR ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY; COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB11/06/2002CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELF CLOSING DOOR AND NO RATED WALL AT TOP OF STAIRS. REMEDY: PROVIDE RATED ENCLOSING FIRE PROOF DOOR AT TOP STAIRS.Nothing owed — awaiting certificate of correction