DOB05/31/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WIND
ECB11/06/2002APARTMENT DOOR OPENS DIRECTLY TO STAIR ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
ECB11/06/2002STAIR ENCLOSURE DOES NOT MEET THE REQUIRED TWO HOUR RATING DUE TO MISSING PIECE OF DRYWALL AT STAIR SIDE OF ENCLOSING WALL IN THE VICINITY OF THE STAIR PLAFORM REMEDY: PROVIDE 2 HR FIRE RATE DRYWALL.Nothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARENothing owed — awaiting certificate of correction
ECB11/06/2002GUARD RAILS ARE NOT PROVIDED AT SECTIONS OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY - PROVIDE GUARD RAILS AT PARAPET LEVEL AT ROOFNothing owed — awaiting certificate of correction
ECB11/06/2002EXTERIOR GAS SERVICE'S NOT PROPERLY PROTECTED BY BOOARDS VEHICULAR TRAFFIC AT 1ST FLOOR PARKING AREA. REMEDY - PROVIDE ADDITIONAL PROTECTIONAROPUND GAS SERVICESNothing owed — awaiting certificate of correction
ECB11/06/2002BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST CONSTRUCTION ( PARAPET WALL ) REMEDY - RAISE FLUE PIPE 3 FEET ABOVE HIGHEST CONSTRUCTIONNothing owed — awaiting certificate of correction
ECB11/06/20021-HOUR RATED BOILER ENCLOSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTEGRITY OF ONE HOUR RATED WALL REMEDY - PROVIDE 1HOUR FIRE PROTECTION AROUND BOILER FLUENothing owed — awaiting certificate of correction
ECB11/06/2002WORK CONTRARY TO PLANS IN THAT GARAGE DIMENSIONS SMALLER THAN SPECIFIED (2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL & CONCRETE (3) REAL LOT RETAINING WALL NOT SHOWN ON PLANS (4) CURB CUT IS 55 FEETNothing owed — awaiting certificate of correction
ECB11/06/2002XLASTIC SKYLIGHTS AT TOP OF STAIR ENCLOSURE ARE NOT PERMITTED SKYLIGHTS ARE NOT VENTED AND NO PROPER WIRE GRATING PROVIDED ABOVE AND BELOW SKYLIGHT. REMEDY: PROVIDE PROPER SKYLIGHT AND GRATING.Nothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE ACCESS TO ROOF VIA INTERIO R STAIR NO ROOF BULK HAEAD PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROVIDED REQUIRED ACCESS TOROOF.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LIN EWINDOWS ARE IMPROPERLY USED TO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION.Nothing owed — awaiting certificate of correction
ECB11/06/2002CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELFT CLOSING DOOR AND RATED WALL AT TOP OF STAIRS. REMEDY: PROVIDE RATED ENCLOSED AND SELF CLOSING FIRE PROOF DOOR AT TOP OF STAIRS.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS.Nothing owed — awaiting certificate of correction
Three families · Owner of record: LEAVITT UNION MANAGEMENT CORP. · 2.92 FAR built · Flood zone X