DOB05/31/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WIND OWS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS 4" CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES ANC BALC ONIES, PARAPET HEIGHTS PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCES S, 60FT CURB CUT, NO PARKING ATTENDANT'S BOOTH
DOB05/31/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS 4" CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALCO NIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30 FT FDNY ACCE SS, 60FT CURB CUT, NO PARKING ATTENDANT'S BOOTH
DOB07/18/2002V-DOB VIOLATION - ACTIVE
DOB07/18/2002V-DOB VIOLATION - ACTIVE
DOB07/18/2002V-DOB VIOLATION - ACTIVE
DOB07/14/2002V-DOB VIOLATION - ACTIVE
ECB08/05/2005RESIDENCE ALTERED FOR OCCUPANCY AS A DWELLING FOR MORE THAN THE LEGALLY APPROVED NUMBER OF FAMILIES. DEPT OF BLDGS RECORDS NB#401230011 INDICATES RESIDENCE TO BE LEGALLY APPROVED FOR A 3 FAMILY WITH RECREATIONNothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARENothing owed — awaiting certificate of correction
ECB11/06/2002GUARD RAILS ARE NOT PROVIDED AT SECTIONS OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY - PROVIDE GUARD RAILS AT PARAPET LEVEL AT ROOFNothing owed — awaiting certificate of correction
ECB11/06/2002EXTERIOR GAS SERVICE NOT PROPERLY PROTECTED BY BOLLARDS FROM VEHICULAR TRAFFIC AT 1ST FLOOR PARKING AREA REMEDY : PROVIDE ADDITIONAL PROTECTION AROUND GAS SERVICE'SNothing owed — awaiting certificate of correction
ECB11/06/2002BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTURCTION ( PARAPET WALL ) REMEDY : RAISE FLUE PIPE 3 FEET ABOVE HIGHEST CONSTRUCTIONNothing owed — awaiting certificate of correction
ECB11/06/20021-HOUR RATED BOILER ENCLOSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTEGRITY OF ONE HOUR RATED WALL REMEDY - PROVIDE 1 HOUR FIRE PROTECTION AROUNG BOILER FLUENothing owed — awaiting certificate of correction
ECB11/06/2002WORK CONTRARY TO PLANS IN THAT GARAGE DIMENSIONS SMALLER THAN SPECIFIED (2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL & CONCRETE (3) REAL LOT RETAINING WALL NOT SHOWN ON PLANS (4) CURB CUT IS 55 FEETNothing owed — awaiting certificate of correction
ECB11/06/2002DID NOT PROVIDE MIN 8% STREET FRONTAGE AS REQUIRED. REMEDY: OBTAIN WAIVER FROM F.D AND C RECONSIDERATION FROM B.CNothing owed — awaiting certificate of correction
ECB11/06/2002PLASTIC SKYLIGHTS AT TOP OF STAIR ENCLOSURE ARE NOT PERMITTED SKYLIGHTS ARE NOT VENTED. AND NO PROPER WIRE GRATING PROVIDED ABOVE AND BELOW SKYLIGHT. REMEDY: PROVIDE PROPER SKYLIGHT AND GRATING.Nothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE ACCESS TO ROOF VIA INTERIOR STAIR NO ROOF BULKHAED PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROVIDE REQUIRED ACCESS TO ROOF.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS ARE IMPROPERLY USED TO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS.Nothing owed — awaiting certificate of correction
ECB11/06/2002APARTMENT DOOR OPENS DIRECTLY TO STAIR ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction
Three families · Owner of record: LEAVITT UNION MANAGEMENT CORP. · 2.92 FAR built · Flood zone X