HPD05/07/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD06/12/2025(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2024(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/30/2023(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB05/31/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WINDO WS, NO HC ACCESS, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRIC METERS W/ BOLLARDS, 4"CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALCO NIES, PARAPET HEIGHTS, PAINTED PARKING IN DRIVEWAY, NO 30FT FDNY ACCES S, 60' CURB CUT, NO PARKING ATTENDANT'S BOOTH
ECB11/06/2002EXTERIOR GAS SERVICES NOT PROPERLY PROTECTED BY BATHARDS FROM VEHICULAR TRAFFIC AT 1 FLOOR PARKING AREA. REMEDY: PROVIDE ADDITIARAL PARATECTIAR AROUND GAS SERVICE.Nothing owed — awaiting certificate of correction
ECB11/06/20021 HOURE RATED BOILER ENCLOUSE (WALL) IS PENETRATED BY AN UNRATED 10' DIAMETER METAL BOILER FLUE COMPROMISING INTEGRATING OF ONE HOUR RATED WALL. REMEDY: PROVIDE 1 HOUR FIRE PROTECTION AROUND BOILER FLUE.Nothing owed — awaiting certificate of correction
ECB11/06/2002BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION (PARAPET WALL). REMEDY: RAISE FLUE PIPE 3 FEET ABOVE HIGHEST ROOF CONSTRUCTION.Nothing owed — awaiting certificate of correction
ECB11/06/2002WORK CONTRARY TO PLANS IN THAT GARAGE DIMENSIONS SMALLER THAN SPECIFIED (2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL & CONCRETE (3) REAR LOT RETAINING WALL NOT SHOWN ON PLANS (4) CURB CUT IS 55 FT RNothing owed — awaiting certificate of correction
ECB11/06/2002DID NOT PROVIDE. MIN 8% STREET FRONTAGE AS REQUIRED. REMEDY: PROVIDE WAIVER FROM F.D AND RECONSIDERATION FROM B.C.Nothing owed — awaiting certificate of correction
ECB11/06/2002PLASTIC SKYLIGHTS AT TOP OF STAIRS ENCLOSER ARE NOT PERMITTED SKYLINGTS ARE NOT VENTED AND NO PROPER WIRE GRATING PROVIDED ABOVE AND BELOW SKYLIGHT. REMEDY: PROVIDE PROPER SKYLIGHT AND GRATING.Nothing owed — awaiting certificate of correction
ECB11/06/2002CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FIRE PROOF SELF CLOSING DOOR AND NO RATED ENCLUSURE WALL AT TOP OF STAIRS. REMEDY: PROVIDE RATED ENCLOSURE AND SELF CLOSING FIRE PROOF DOOR AT TOP OF STAIRS.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS.Nothing owed — awaiting certificate of correction
ECB11/06/2002APARTMENT DOOR DIRECTLY TO STAIR ENCLOUSRE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY: COMPLY WITH CODENothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARENothing owed — awaiting certificate of correction
ECB11/06/2002GUARD RAILS ARE NOT PROVIDED AT SECTION OF BRICK PARAPET THAT ARE LESS THAN 3 OF 6. REMEDY: PROVIDE GUARDRAILS AT PARAPET LEVEL AT ROOF.Nothing owed — awaiting certificate of correction
Three families · Owner of record: LEAVITT UNION MANAGEMENT CORP. · 2.92 FAR built · Flood zone X