HPD05/07/2026(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD06/12/2025(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2024(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/30/2023(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD03/08/2022(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
HPD04/16/2021(A) § HMC:FILE ANNUAL BEDBUG REPORT IN ACCORDANCE WITH HPD RULE AS DESCRIBED ON THE BACK OF THIS NOTICE OF VIOLATION OR AS DESCRIBED ON HPDS WEBSITE, WWW.NYC.GOV\HPD, SEARCH BED BUGS.
DOB05/31/2007AS BUILT CONDITIONS NOT CONFORMING TO APPROVED PLANS AS FOLLOWS: WIND OWS, NO HC ACCESS OR LIFT, INDIVIDUAL GRATES, EXTERIOR GAS AND ELECTRI C METERS W/ BOLLARDS, 4"CMU FACADE, NO FIRE RATED STEEL BRICK SHELVES AND BALCONIES, PARAPET HEIGHTS, PAINTED PARKING DRIVEWAY, NO 30FT FDNY ACCESS, 60FT CURB CUT, NO PARKING ATTENDANT'S BOOTH
DOB07/18/2002V-DOB VIOLATION - ACTIVE
DOB07/18/2002V-DOB VIOLATION - ACTIVE
DOB07/18/2002V-DOB VIOLATION - ACTIVE
DOB07/18/2002V-DOB VIOLATION - ACTIVE
ECB11/06/2002GUARDRAILS ATE NOT PROVIEDED AT SECTIONS OF BRICK PARAPET THAT ARE LESS THAN 3F 6" REMEDY : PROVIDE GUARDRIALS AT PARAPET LEVEL AT ROOFNothing owed — awaiting certificate of correction
ECB11/06/2002EXTERIOR GAS SERVICE NOT PROPERLY PROTECTED BY BALLORDS FROM VEHICULARTRAFFIC AT 1ST FLOOR PARKING AREA REMEDY : PROVIDE ADDTIONAL PROTECTION AROUND GAS SERVICE'SNothing owed — awaiting certificate of correction
ECB11/06/2002BOILER FLUE NOT CARRIED 3 FEET ABOVE HIGHEST ROOF CONSTURCTION ( PARAPET WALL ) REMEDY : RAISE FLUE PIPE 3 FEET ABOVE HIGHEST CONSTRUCTIONNothing owed — awaiting certificate of correction
ECB11/06/20021-HOUR RATED BOILER ENCLOSURE (WALL) IS PENETRATED BY AN UNRATED 10" DIAMETER METAL BOILER FLUE COMPROMISING INTEGRITY OF ONE HOUR RATED WALL REMEDY - PROVIDE 1 HOUR FIRE PROTECTION AROUND BOILER FLUENothing owed — awaiting certificate of correction
ECB11/06/2002WORK CONTRARY TO PLANS IN THAT GARAGE DIMENSIONS SMALLER THAN SPECIFIED (2) ROOF DECKING CONSTRUCTED OF PLYWOOD INSTEAD OF METAL & CONCRETE (3) REAL LOT RETAINING WALL NOT SHOWN ON PLANS (4) CURB CUT IS 55 FEETNothing owed — awaiting certificate of correction
ECB11/06/2002DID NOT PROVIDE MAIN 8% STREET FRONTAGE AS REQUIRED. REMEDY: PROVIDE WAIVER FROM F.D AND RECONDITION FROM B.CNothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE ACCESS TO ROOF VIAL INTERIOR STAIR NO ROOF BULKHEAD PROVIDED FOR 4 FAMILY DWELLING. REMEDY: PROVIDE REQUIRED ACCESS TO ROOF.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS ARE IMPROPERLY USE DTO SUPPLY REQUIRED VENTILATION. REMEDY: PROVIDE PROPER VENTILATION.Nothing owed — awaiting certificate of correction
ECB11/06/2002CELLAR STAIR IS NOT ENCLOSED BECAUSE THERE IS NO FURE PROOF SELF CLOSING DOOR AND NO RATED WALL AT TOP OF STAIRS. REMEDY: PROVIDE RATED ENCLOSURE & SELF CLOSING FIRE DOOR AT TOP OF STAIRS.Nothing owed — awaiting certificate of correction
ECB11/06/2002LOT LINE WINDOWS INSTALLED WITHOUT A PERMIT NOT SHOWN ON PLANS. REMEDY: OBTAIN A PERMIT OR REMOVE WINDOWS.Nothing owed — awaiting certificate of correction
ECB11/06/2002PLASTIC SKYLIGHTS AT TOP OF STAIR ENCLOSURE ARENOT PERMITTED. SKYLIGHTS ARE NOT VENTED AND NO PROPER WIRE GRATING PROVIDED ABOVE AND BELOW SKYLIGHT. REMEDY: PROVIDE PROPER SKYLIGHT AND GRATING.Nothing owed — awaiting certificate of correction
ECB11/06/2002FAILURE TO PROVIDE REQUIRED NUMBER OF PARKING SPACES IN AN R6 DISTRICT ENCLOSED ACCESSARY OFF STREET PARKING SPACE DOES NOT MEET MININUM DIMENSIANS OF 18.5 X 8. UNENCLOSED OFF STREET PARKING SPACES AT REAR ARENothing owed — awaiting certificate of correction
ECB11/06/2002APARTMENT DOOR OPENS DIRECTLY TO STAIR ENCLOSURE WHICH IS NOT PERMITTED IN A BUILDING OVER THREE STORIES. REMEDY: COMPLY WITH CODE.Nothing owed — awaiting certificate of correction